{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T20:02:03Z","timestamp":1787169723708,"version":"build-2736575974"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>Spine kinematic determination is required to diagnose or rehabilitate back pain due to spinal instability. Ultrasound imaging, as a less harmful and cost-effective method, has been recently applied to kinematic analysis. This study reviews all available published articles to see how much progress has been made in spine kinematic measurement by ultrasound. In this regard, we searched PubMed, Scopus, and Google Scholar among all available studies until 2021, using keywords such as ultrasound, spine, kinematics, rotation, twist, flexion, and bending. Finally, after identifying and scanning 183 articles, only nine articles were included, which analyzed spine kinematics by ultrasound. Among these nine articles, three reported axial displacements, three reported flexion\/extension, and three reported axial rotation. Although ultrasound is a suitable alternative to other kinematic measurement methods, very little research and progress have been made in this area. Today, this method is still not used practically for spine kinematic measurement because the bone scans via ultrasound imaging are challenging to understand, and no three-dimensional kinematic measurement technique has been reported. However, recent advances in converting ultrasound images into three-dimensional images can pave the way for further improvements.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jmu.jmu_200_21","type":"journal-article","created":{"date-parts":[[2022,3,24]],"date-time":"2022-03-24T00:06:52Z","timestamp":1648080412000},"page":"6-10","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Application of Ultrasound in Spine Kinematic Determination"],"prefix":"10.4103","volume":"30","author":[{"given":"Mohammad Reza","family":"Effatparvar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"St\u00e9phane","family":"Sobczak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-3-20240830","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1016\/S0140-6736(17)32154-2","article-title":"Global, regional, and national incidence, prevalence, and years lived with disability for 328 diseases and injuries for 195 countries, 1990\u20132016: A systematic analysis for the Global Burden of Disease Study 2016","volume":"390","author":"Vos","year":"2017","journal-title":"Lancet"},{"key":"R2-3-20240830","doi-asserted-by":"crossref","first-page":"1444","DOI":"10.1001\/jama.2018.0158","article-title":"The state of US health, 1990-2016: burden of diseases, injuries, and risk factors among US states","volume":"319","author":"Mokdad","year":"2018","journal-title":"Jama"},{"key":"R3-3-20240830","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1186\/s12891-017-1452-1","article-title":"Current management practices for patients presenting with low back pain to a large emergency department in Canada","volume":"18","author":"Nunn","year":"2017","journal-title":"BMC Musculoskelet Disord"},{"key":"R4-3-20240830","doi-asserted-by":"crossref","first-page":"E413","DOI":"10.1097\/BRS.0b013e3181dc844a","article-title":"Musculoskeletal modeling of the suboccipital spine: Kinematics analysis, muscle lengths, and muscle moment arms during axial rotation and flexion extension","volume":"36","author":"Dugailly","year":"2011","journal-title":"Spine (Phila Pa 1976"},{"key":"R5-3-20240830","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1007\/s00276-009-0556-1","article-title":"In vitro 3D-kinematics of the upper cervical spine: Helical axis and simulation for axial rotation and flexion extension","volume":"32","author":"Dugailly","year":"2010","journal-title":"Surg Radiol Anat"},{"key":"R6-3-20240830","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/j.jocn.2019.05.006","article-title":"Thoracic spine disc degeneration, translation, and angular motion: An analysis using thoracic spine kinematic MRI (kMRI)","volume":"66","author":"Paholpak","year":"2019","journal-title":"J Clin Neurosci"},{"key":"R7-3-20240830","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1186\/s12891-017-1721-z","article-title":"Differences in lumbar spine and lower extremity kinematics in people with and without low back pain during a step-up task: A cross-sectional study","volume":"18","author":"Mitchell","year":"2017","journal-title":"BMC Musculoskelet Disord"},{"key":"R8-3-20240830","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.math.2015.07.005","article-title":"3D motion reliability of occipital condylar glide testing: From concept to kinematics evidence","volume":"21","author":"Beyer","year":"2016","journal-title":"Man Ther"},{"key":"R9-3-20240830","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1016\/j.math.2010.05.004","article-title":"Soft tissue artefact in the thoracic spine during axial rotation and arm elevation using ultrasound imaging: A descriptive study","volume":"15","author":"Heneghan","year":"2010","journal-title":"Man Ther"},{"key":"R10-3-20240830","doi-asserted-by":"crossref","first-page":"3","DOI":"10.11152\/mu.2013.2066.171.ezn","article-title":"Ultrasound in rheumatology: Two decades of rapid development and evolving implementation","volume":"17","author":"Naredo","year":"2015","journal-title":"Med Ultrason"},{"key":"R11-3-20240830","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.jemermed.2013.08.001","article-title":"New heights in ultrasound: First report of spinal ultrasound from the international space station","volume":"46","author":"Marshburn","year":"2014","journal-title":"J Emerg Med"},{"key":"R12-3-20240830","doi-asserted-by":"crossref","first-page":"101050","DOI":"10.1016\/j.disamonth.2020.101050","article-title":"Current advances and research in ultrasound imaging to the assessment and management of musculoskeletal disorders","volume":"67","author":"Romero-Morales","year":"2021","journal-title":"Dis Mon"},{"key":"R13-3-20240830","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1007\/s11012-016-0478-z","article-title":"Application of ultrasound imaging to subject-specific modelling of the human musculoskeletal system","volume":"52","author":"Passmore","year":"2017","journal-title":"Meccanica"},{"key":"R14-3-20240830","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1097\/ALN.0b013e31821a8ad4","article-title":"Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks","volume":"115","author":"Chin","year":"2011","journal-title":"Anesthesiology"},{"key":"R15-3-20240830","doi-asserted-by":"crossref","first-page":"2115","DOI":"10.1007\/s11517-019-02015-9","article-title":"A semi-automatic 3D ultrasound reconstruction method to assess the true severity of adolescent idiopathic scoliosis","volume":"57","author":"Vo","year":"2019","journal-title":"Med Biol Eng Comput"},{"key":"R16-3-20240830","doi-asserted-by":"crossref","first-page":"S7","DOI":"10.1186\/1748-7161-10-S2-S7","article-title":"Measurement of axial vertebral rotation using three-dimensional ultrasound images","volume":"10","author":"Vo","year":"2015","journal-title":"Scoliosis"},{"key":"R17-3-20240830","first-page":"1540","article-title":"3D ultrasound imaging method to assess the true spinal deformity","volume":"2015","author":"Vo","year":"2015","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"R18-3-20240830","doi-asserted-by":"crossref","first-page":"1473","DOI":"10.1016\/j.ultrasmedbio.2016.02.011","article-title":"Validity study of vertebral rotation measurement using 3-D ultrasound in adolescent idiopathic scoliosis","volume":"42","author":"Wang","year":"2016","journal-title":"Ultrasound Med Biol"},{"key":"R19-3-20240830","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: An updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","journal-title":"BMJ"},{"key":"R20-3-20240830","doi-asserted-by":"crossref","first-page":"684840","DOI":"10.3389\/fnut.2021.684840","article-title":"Assessment of tongue strength in sarcopenia and sarcopenic dysphagia: A systematic review and meta-analysis","volume":"8","author":"Chen","year":"2021","journal-title":"Front Nutr"},{"key":"R25-3-20240830","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1016\/j.ultrasmedbio.2016.01.001","article-title":"Development and validation of a method to measure lumbosacral motion using ultrasound imaging","volume":"42","author":"van den Hoorn","year":"2016","journal-title":"Ultrasound Med Biol"},{"key":"R26-3-20240830","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1016\/j.ultrasmedbio.2015.02.015","article-title":"Development of a new ultrasound-based system for tracking motion of the human lumbar spine: Reliability, stability and repeatability during forward bending movement trials","volume":"41","author":"Cuesta-Vargas","year":"2015","journal-title":"Ultrasound Med Biol"},{"key":"R27-3-20240830","doi-asserted-by":"crossref","first-page":"880","DOI":"10.2519\/jospt.2012.3915","article-title":"Measurement of segmental lumbar spine flexion and extension using ultrasound imaging","volume":"42","author":"Chleboun","year":"2012","journal-title":"J Orthop Sports Phys Ther"},{"key":"R28-3-20240830","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1016\/j.math.2008.10.004","article-title":"Stability and intra-tester reliability of an in vivo measurement of thoracic axial rotation using an innovative methodology","volume":"14","author":"Heneghan","year":"2009","journal-title":"Man Ther"},{"key":"R29-3-20240830","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1016\/j.ultrasmedbio.2018.10.023","article-title":"Validation of an ultrasound protocol to measure intervertebral axial twist during functional twisting movements in isolated functional spinal units","volume":"45","author":"McKinnon","year":"2019","journal-title":"Ultrasound Med Biol"},{"key":"R30-3-20240830","doi-asserted-by":"crossref","first-page":"102824","DOI":"10.1016\/j.humov.2021.102824","article-title":"The relationship between external thoracopelvic angle and lumbar segmental axial twist angle using an ultrasound imaging technique","volume":"78","author":"McKinnon","year":"2021","journal-title":"Hum Mov Sci"},{"key":"R32-3-20240830","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/j.gaitpost.2008.05.005","article-title":"The in vivo three-dimensional motion of the human lumbar spine during gait","volume":"28","author":"Rozumalski","year":"2008","journal-title":"Gait Posture"},{"key":"R33-3-20240830","doi-asserted-by":"crossref","first-page":"937","DOI":"10.3233\/BMR-200259","article-title":"Musculoskeletal ultrasound for 3D bone modeling: A preliminary study applied to lumbar vertebra","volume":"34","author":"Forbes","year":"2021","journal-title":"J Back Musculoskelet Rehabil"}],"container-title":["Journal of Medical Ultrasound"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jmu.jmu_200_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:11:09Z","timestamp":1787166669000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jmu.jmu_200_21"}},"subtitle":["A Systemic Review"],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/jmu.jmu_200_21","relation":{},"ISSN":["0929-6441"],"issn-type":[{"value":"0929-6441","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1]]}}}