{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T19:17:59Z","timestamp":1791487079830,"version":"4.3.4"},"reference-count":16,"publisher":"Scientific Scholar","issue":"02","license":[{"start":{"date-parts":[[2019,8,20]],"date-time":"2019-08-20T00:00:00Z","timestamp":1566259200000},"content-version":"vor","delay-in-days":141,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Neurosciences in Rural Practice"],"published-print":{"date-parts":[[2019,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title><jats:p>\n          Background: Pedicle screw fixation is one of the widely used procedures for instrumentation and stabilization of the thoracic and lumbar spine. It has the advantage of stabilizing all the three columns in single approach. Various assistive techniques are available to place the pedicle screws more accurately but at the expense of increased exposure to radiation, prolonged surgical duration, and cost. Objective: The objective of this study is to determine the accuracy and safety of pedicle screw fixation in the thoracolumbar spine using freehand surgical technique. Materials and Methods: We evaluated all patients who underwent pedicle screw fixation of the thoracolumbar spine for various ailments at our institute from January 2016 to December 2017 with postoperative computed tomography scan for placement accuracy. We used Gertzbein classification to grade pedicle breaches. Screw penetration more than 4 mm was taken as critical and those less than that were classified as noncritical. Results: A total of 256 screws inserted in T1\u2013L5 vertebrae were included from 40 consecutive patients. Six screws were excluded according to selection criteria. The mean age was 39 years. Trauma (36 patients) was the common reason for which the pedicle screw fixation was done followed by degenerative disease (2 patients) and tumour (2 patients). A total of ten pedicle screw breaches (4%) were identified in eight patients. Among these, three critical breaches (1.2%) were occurred in two patients which required revision. The remaining seven breaches were noncritical and kept under close observation and follow-up. Conclusion: Pedicle screw had become the workhorse of posterior stabilization of the spine. Based on external anatomy and landmarks alone, freehand technique for pedicle screw fixation can be performed with acceptable safety and accuracy avoiding cumulative radiation exposure and prolonged operative time.<\/jats:p>","DOI":"10.4103\/jnrp.jnrp_183_18","type":"journal-article","created":{"date-parts":[[2019,3,22]],"date-time":"2019-03-22T04:20:03Z","timestamp":1553228403000},"page":"256-260","source":"Crossref","is-referenced-by-count":6,"title":["Is Freehand Technique of Pedicle Screw Insertion in Thoracolumbar Spine Safe and Accurate? Assessment of 250 Screws"],"prefix":"10.25259","volume":"10","author":[{"given":"N.","family":"Vijayeswaran","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Coimbatore Medical College and Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raju","family":"Venkatesh","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Coimbatore Medical College and Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Murugesan","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Coimbatore Medical College and Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Balamurugan","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Coimbatore Medical College and Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Indunesh","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Coimbatore Medical College and Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T. T.","family":"Pradeep","sequence":"additional","affiliation":[{"name":"Department of Neurosurgery, Coimbatore Medical College and Hospital, Coimbatore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2019,8,20]]},"reference":[{"key":"key-10.4103\/0976-3147.254652-1","first-page":"248","volume-title":"A method of spinal fusion","author":"Boucher","year":"1959","journal-title":"J Bone Joint Surg Br"},{"key":"key-10.4103\/0976-3147.254652-2","first-page":"147","volume-title":"Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates","author":"Roy-Camille","year":"1986","journal-title":"Orthop Clin North Am"},{"key":"key-10.4103\/0976-3147.254652-3","first-page":"771","volume-title":"Stereotactic navigation for placement of pedicle screws in the thoracic spine","author":"Youkilis","year":"2001","journal-title":"Neurosurgery"},{"key":"key-10.4103\/0976-3147.254652-4","first-page":"730","volume-title":"Computer-assisted fluoroscopic navigation of pedicle screw insertion: An in vivo feasibility study","author":"Fu","year":"2004","journal-title":"Acta Orthop Scand"},{"key":"key-10.4103\/0976-3147.254652-5","first-page":"606","volume-title":"Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine","author":"Amiot","year":"1976","journal-title":"Spine (Phila Pa"},{"key":"key-10.4103\/0976-3147.254652-6","first-page":"170","volume-title":"Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: Analysis of 6816 consecutive screws","author":"Parker","year":"2011","journal-title":"Neurosurgery"},{"key":"key-10.4103\/0976-3147.254652-7","first-page":"221","volume-title":"Incidence of clinically diagnosed vertebral fractures: A population-based study in Rochester, Minnesota, 1985-1989","author":"Cooper","year":"1992","journal-title":"J Bone Miner Res"},{"key":"key-10.4103\/0976-3147.254652-8","first-page":"367","volume-title":"Accuracy of computed tomography in assessing thoracic pedicle screw malposition","author":"Fayyazi","year":"2004","journal-title":"J Spinal Disord Tech"},{"key":"key-10.4103\/0976-3147.254652-9","first-page":"223","volume-title":"Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement","author":"Rao","year":"2002","journal-title":"J Neurosurg"},{"key":"key-10.4103\/0976-3147.254652-10","first-page":"2637","volume-title":"Radiation exposure to the spine surgeon during fluoroscopically assisted pedicle screw insertion","author":"Rampersaud","year":"1976","journal-title":"Spine (Phila Pa"},{"key":"key-10.4103\/0976-3147.254652-11","first-page":"58","volume-title":"Advanced image guidance for the placement of thoracic pedicle screws","author":"Rampersaud","year":"2002","journal-title":"Sem Spine Surg"},{"key":"key-10.4103\/0976-3147.254652-12","first-page":"333","volume-title":"Free hand pedicle screw placement in the thoracic spine: Is it safe?","author":"Kim","year":"1976","journal-title":"Spine (Phila Pa"},{"key":"key-10.4103\/0976-3147.254652-13","first-page":"520","volume-title":"Accuracy and safety of pedicle screw fixation in thoracic spine trauma","author":"Fisher","year":"2006","journal-title":"J Neurosurg Spine"},{"key":"key-10.4103\/0976-3147.254652-14","first-page":"11","volume-title":"Accuracy of pedicular screw placement in vivo","author":"Gertzbein","year":"1976","journal-title":"Spine (Phila Pa"},{"key":"key-10.4103\/0976-3147.254652-15","first-page":"1558","volume-title":", Klemme WR, Robinson M, Polly DW Jr.Accuracy of thoracic pedicle screws in patients with and without coronal plane spinal deformities","author":"Belmont","year":"1976","journal-title":"Spine (Phila Pa"},{"key":"key-10.4103\/0976-3147.254652-16","first-page":"1200","volume-title":"Placement of pedicle screws in the thoracic spine.Part II: An anatomical and radiographic assessment","author":"Vaccaro","year":"1995","journal-title":"J Bone Joint Surg Am"}],"container-title":["Journal of Neurosciences in Rural Practice"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.4103\/jnrp.jnrp_183_18.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,5]],"date-time":"2023-08-05T04:16:23Z","timestamp":1691208983000},"score":1,"resource":{"primary":{"URL":"https:\/\/ruralneuropractice.com\/is-freehand-technique-of-pedicle-screw-insertion-in-thoracolumbar-spine-safe-and-accurate-assessment-of-250-screws\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4]]},"references-count":16,"journal-issue":{"issue":"02","published-online":{"date-parts":[[2019,8,20]]},"published-print":{"date-parts":[[2019,4]]}},"URL":"https:\/\/doi.org\/10.4103\/jnrp.jnrp_183_18","relation":{},"ISSN":["0976-3147","0976-3155"],"issn-type":[{"value":"0976-3147","type":"print"},{"value":"0976-3155","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,4]]}}}