{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T20:32:04Z","timestamp":1786739524942,"version":"build-2736575974"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>Successful intubation with video laryngoscopes necessitates good hand-eye coordination and the use of intubation adjuncts like bougie and stylet. We proposed this study to find whether using Frova introducer with C-MAC video laryngoscope will reduce the intubation time in trainee anesthesiologists.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>\n                      We enrolled 140 adults without any difficult airway predictors. They were randomly assigned to undergo C-MAC video laryngoscope guided intubation by anesthesia residents using tracheal tube preloaded over Frova introducer (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 70) or without Frova introducer (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 70). Primary outcome was the intubation time. Secondary outcomes were the number of redirections of tracheal tube or Frova introducer toward glottis, need for external laryngeal maneuvers (ELMs), first attempt intubation success rate, and ease of intubation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The median actual intubation time (IQR) in Frova and non-Frova group, respectively, were 25.46 (28.11\u201319.80) and 19.96 (26.59\u201315.52) s (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001). The number of redirections of TT or Frova introducer toward glottis, first attempt success rate, and ease of intubation were comparable. The need for ELMs [\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      (%)] was 15 (21.4) and 26 (37.1) in Frova and non-Frova group, respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.04).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Frova introducer guided endotracheal intubation with C-MAC videolaryngoscope in patients with normal airways had a marginally prolonged intubation time with a significant reduction in the need of external laryngeal manoeuvres but with a comparable number of redirections and attempts. Further research is needed to generalize these findings to patients with difficult airways.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/joacp.joacp_263_20","type":"journal-article","created":{"date-parts":[[2021,1,18]],"date-time":"2021-01-18T07:20:28Z","timestamp":1610954428000},"page":"483-488","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of conventional C-MAC video laryngoscope guided intubation by anesthesia trainees with and without Frova endotracheal introducer"],"prefix":"10.4103","volume":"36","author":[{"given":"Meenupriya","family":"Arasu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Priya","family":"Rudingwa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.V.S","family":"Satyaprakash","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sakthirajan","family":"Panneerselvam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aswini","family":"Kuberan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-10-20260203","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1111\/j.1365-2044.2011.06872.x","article-title":"Performance of the C-MAC video laryngoscope in patients after a limited glottic view using Macintosh laryngoscopy: C-MAC in limited glottic view","volume":"66","author":"Piepho","year":"2011","journal-title":"Anaesthesia"},{"key":"R2-10-20260203","doi-asserted-by":"crossref","first-page":"831","DOI":"10.2147\/TCRM.S136221","article-title":"Current evidence for the use of C-MAC videolaryngoscope in adult airway management: A review of the literature","volume":"13","author":"Xue","year":"2017","journal-title":"Ther Clin Risk Manag"},{"key":"R3-10-20260203","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1111\/j.1365-2044.2008.05855.x","article-title":"Laryngoscopy: Time to change our view","volume":"64","author":"Frerk","year":"2009","journal-title":"Anaesthesia"},{"key":"R4-10-20260203","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1093\/bja\/aev371","article-title":"Difficult airway society 2015 guidelines for management of unanticipated difficult intubation in adults","volume":"115","author":"Frerk","year":"2015","journal-title":"Br J Anaesth"},{"key":"R5-10-20260203","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/S0952-8180(02)00457-9","article-title":"A new video laryngoscope \u2013 An aid to intubation and teaching","volume":"14","author":"Kaplan","year":"2002","journal-title":"J Clin Anaesth"},{"key":"R6-10-20260203","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1111\/j.1365-2044.2010.06245.x","article-title":"Determination of the optimal stylet strategy for the C-MAC video laryngoscope: Stylet use with C-MAC video laryngoscope","volume":"65","author":"Mc Elwain","year":"2010","journal-title":"Anaesthesia"},{"key":"R7-10-20260203","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1213\/ane.0b013e3181ae39db","article-title":"A Macintosh laryngoscope blade for videolaryngoscope reduces stylet use in patients with normal airways","volume":"109","author":"van Zunderty","year":"2009","journal-title":"Anesth Analg"},{"key":"R8-10-20260203","doi-asserted-by":"crossref","first-page":"163","DOI":"10.4172\/2155-6148.1000163","article-title":"A randomized comparison of C-MAC videolaryngscope versus macintosh laryngoscope for tracheal intubation","volume":"2","author":"Hodgetts","year":"2011","journal-title":"J Anesth Clin Res"},{"key":"R9-10-20260203","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.bjan.2013.03.001","article-title":"effectiveness of the C-MAC video laryngoscope in the management of unexpected failed intubations","volume":"64","author":"Kilicaslan","year":"2014","journal-title":"Rev Bras Anestesiol"},{"key":"R10-10-20260203","doi-asserted-by":"crossref","first-page":"R103","DOI":"10.1186\/cc11384","article-title":"Endotracheal intubation using the C-MAC video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU","volume":"16","author":"Noppens","year":"2012","journal-title":"Crit Care"},{"key":"R11-10-20260203","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1155\/2016\/8943931","article-title":"Comparing McGRATH\u00ae MAC, C-MAC\u00ae, and Macintosh laryngoscope operated by medical students: A randomized crossover, Manikin study","volume":"2016","author":"Shin","year":"2016","journal-title":"Biomed Res Int"},{"key":"R12-10-20260203","doi-asserted-by":"crossref","first-page":"2179","DOI":"10.1001\/jama.2018.6496","article-title":"Effect of use of a bougie vs endotracheal tube and stylet on first-attempt intubation success among patients with difficult airways undergoing emergency intubation: A randomized clinical trial","volume":"319","author":"Driver","year":"2018","journal-title":"JAMA"},{"key":"R13-10-20260203","doi-asserted-by":"crossref","first-page":"310","DOI":"10.4097\/kjae.2014.66.4.310","article-title":"Combined use of a McGrath MAC video laryngoscope and Frova intubating introducer in a patient with Pierre Robin syndrome: A case report","volume":"66","author":"Kim","year":"2014","journal-title":"Korean J Anesthesiol"},{"key":"R14-10-20260203","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1111\/j.1365-2044.2004.03809.x","article-title":"Evaluation of Frova, single use intubation introducer, in a mannikin. Comaprison with Eschmann multiple use introducer and Portex single use introducer","volume":"59","author":"Hodzovic","year":"2004","journal-title":"Anaesthesia"},{"key":"R15-10-20260203","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1046\/j.1365-2044.2003.02871.x","article-title":"A comparison of simulated difficult intubation with multiple use and single use bougies in a mannikin","volume":"58","author":"Annamaneni","year":"2003","journal-title":"Anaesthesia"},{"key":"R16-10-20260203","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1111\/j.1365-2044.2005.04168.x","article-title":"A comparison of multiple use and single use bougies","volume":"60","author":"Whitcombe","year":"2005","journal-title":"Anaesthesia"},{"key":"R17-10-20260203","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1111\/anae.14182","article-title":"A before-and-after observational study of a protocol for use of the C-MAC videolaryngoscope with a Frova introducer in pre-hospital rapid sequence intubation","volume":"73","author":"Angerman","year":"2018","journal-title":"Anaesthesia"},{"key":"R18-10-20260203","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1111\/j.1742-6723.2011.01506.x","article-title":"Comparison of intubation performance by junior emergency department doctors using gum elastic bougie versus stylet reinforced endotracheal tube insertion techniques: Dose a bougie improve intubation?","volume":"24","author":"Brazil","year":"2012","journal-title":"Emerg Med Australas"},{"key":"R19-10-20260203","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1111\/anae.12600","article-title":"The humble bougie\u2026 forty years and still counting?","volume":"69","author":"Rai","year":"2014","journal-title":"Anaesthesia"},{"key":"R20-10-20260203","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1111\/j.1365-2044.2007.05322.x","article-title":"Evaluation of clinical effectiveness of the Frova single-use tracheal tube introducer","volume":"63","author":"Hodzovic","year":"2008","journal-title":"Anaesthesia"},{"key":"R21-10-20260203","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1097\/EJA.0000000000000070","article-title":"Comparison between bougies and stylet for simulated tracheal intubation with the C-MAC D blade video laryngoscope","volume":"32","author":"Batuwitage","year":"2015","journal-title":"Eur J Anaesthesiol"},{"key":"R22-10-20260203","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1111\/acem.12055","article-title":"The importance of first-pass success when performing orotracheal intubation in the emergency department","volume":"20","author":"Sakles","year":"2013","journal-title":"Acad Emerg Med"},{"key":"R23-10-20260203","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1016\/j.annemergmed.2012.04.005","article-title":"Association between repeated intubation attempts and adverse events in emergency departments: An analysis of a multicenter prospective observational study","volume":"60","author":"Hasegawa","year":"2012","journal-title":"Ann Emerg Med"},{"key":"R24-10-20260203","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1213\/01.ANE.0000122825.04923.15","article-title":"Emergency tracheal intubation: Complications associated with repeated laryngoscopic attempts","volume":"99","author":"Mort","year":"2004","journal-title":"Anesth Analg"}],"container-title":["Journal of Anaesthesiology Clinical Pharmacology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/joacp.JOACP_263_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:29:41Z","timestamp":1786735781000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/joacp.JOACP_263_20"}},"subtitle":["A randomized clinical trial"],"short-title":[],"issued":{"date-parts":[[2020,10]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.4103\/joacp.joacp_263_20","relation":{},"ISSN":["0970-9185"],"issn-type":[{"value":"0970-9185","type":"print"}],"subject":[],"published":{"date-parts":[[2020,10]]}}}