{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T21:32:22Z","timestamp":1790803942701,"version":"4.1.0"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>Robotic surgeries often require a relatively long duration of pneumo-peritoneum and trendelenburg position which may accentuate changes in endo-tracheal tube (ETT) cuff pressure leading to pressure related complications. The aim of this study was to analyze changes in ETT cuff pressures during various stages of pneumo-peritoneum and surgical positioning and its correlation with airway pressure changes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>\n                      A prospective observational study was planned after approval of institutional review board on 60 patients undergoing elective robotic pelvic surgery requiring head down position. Baseline cuff pressure was adjusted to 25 cm H\n                      <jats:sub>2<\/jats:sub>\n                      O. ETT cuff pressure, peak airway pressure and end tidal CO\n                      <jats:sub>2<\/jats:sub>\n                      (ETCO\n                      <jats:sub>2<\/jats:sub>\n                      ) was measured at various time intervals before and after pneumo-peritoneum and head down. Ventilatory parameters were kept fixed after baseline setting. Those requiring any change were excluded. Pearson\u2019s coefficient was used for correlation and ANOVA for trend of parameters at different time intervals (P value &lt;0.05 was considered significant).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Baseline cuff pressure after manual inflation was 46.2 \u00b1 17.4 cm H\n                      <jats:sub>2<\/jats:sub>\n                      O. Significant correlation was observed between change in cuff pressure and increase in peak airway pressure at the end of the surgery (r = 0.4, P &lt; 0.05). Serial measurements of ETT cuff pressure, peak airway pressure and ETCO\n                      <jats:sub>2<\/jats:sub>\n                      were significantly increased compared to baseline (P &lt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Significant increases in ETT cuff pressure may be seen in robotic surgeries, with a positive correlation between change in cuff pressure and increase in airway pressures. Objective adjusted measurement of cuff pressure and airway pressures is recommended for such surgeries.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/joacp.joacp_325_20","type":"journal-article","created":{"date-parts":[[2022,7,27]],"date-time":"2022-07-27T07:28:39Z","timestamp":1658906919000},"page":"270-274","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["A prospective observational study on changes in endo-tracheal tube cuff pressure and its correlation with airway pressures during various stages of robotic pelvic surgeries"],"prefix":"10.4103","volume":"38","author":[{"given":"Priyanka","family":"Gupta","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shipra","family":"Tandon","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mridul","family":"Dhar","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ankit","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sharmishtha","family":"Pathak","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Prabakaran","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,7,28]]},"reference":[{"key":"R1-20240828","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1213\/ANE.0000000000002657","article-title":"Effects of increasing airway pressures on the pressure of the endotracheal tube cuff during pelvic laparoscopic surgery","volume":"127","author":"Rosero","year":"2018","journal-title":"Anaesth Analg"},{"key":"R2-20240828","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.bjan.2014.06.005","article-title":"In vitro evaluation of the method effectiveness to limit inflation pressure cuffs of endotracheal tubes","volume":"66","author":"Coelho","year":"2016","journal-title":"Rev Bras Anaestesiol"},{"key":"R3-20240828","doi-asserted-by":"crossref","first-page":"358","DOI":"10.4103\/0970-9185.83682","article-title":"Endotracheal tube cuff pressure monitoring during neurosurgery-Manual vs. automatic method","volume":"27","author":"Jain","year":"2011","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"R4-20240828","doi-asserted-by":"crossref","first-page":"1787","DOI":"10.3390\/jcm8111787","article-title":"The effect of adjustment of endotracheal tube cuff pressure during scarless remote access endoscopic and robotic thyroidectomy on laryngo-pharyngeal complications:Prospective randomized and controlled trial","volume":"8","author":"Koo","year":"2019","journal-title":"J Clin Med"},{"issue":"suppl_1","key":"R5-20240828","doi-asserted-by":"crossref","first-page":"i72","DOI":"10.1093\/bja\/aex383","article-title":"The evolution of robotic surgery:Surgical and anaesthetic aspects","volume":"119","author":"Ashrafian","year":"2017","journal-title":"Br J Anaesth"},{"key":"R6-20240828","doi-asserted-by":"crossref","first-page":"18","DOI":"10.4103\/0019-5049.76577","article-title":"Robotic invasion of operation theatre and associated anaesthetic issues:A review","volume":"55","author":"Kakar","year":"2011","journal-title":"Indian J Anaesth"},{"key":"R7-20240828","doi-asserted-by":"crossref","first-page":"75","DOI":"10.4103\/0974-1216.114077","article-title":"Anaesthetic implications of robotic gynecologic surgery","volume":"2","author":"McLarney","year":"2011","journal-title":"J Gynecol Endosc Surg"},{"key":"R8-20240828","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1186\/1471-2253-14-75","article-title":"Changes in endotracheal tube cuff pressure during laparoscopic surgery in head-up or head-down position","volume":"14","author":"Wu","year":"2014","journal-title":"BMC Anaesthesiol"},{"key":"R9-20240828","doi-asserted-by":"crossref","first-page":"237","DOI":"10.4103\/2229-5151.170841","article-title":"Endotracheal cuff pressure changes with change in position in neurosurgical patients","volume":"5","author":"Athiraman","year":"2015","journal-title":"Int J Crit Illn Inj Sci"},{"key":"R10-20240828","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1590\/S1806-37132008000500008","article-title":"Endotracheal tube cuff pressure alteration after changes in position in patients under mechanical ventilation","volume":"34","author":"Godoy","year":"2008","journal-title":"J Bras Pneumol"},{"key":"R11-20240828","doi-asserted-by":"crossref","first-page":"27","DOI":"10.4097\/kjae.2015.68.1.27","article-title":"The changes of endotracheal tube cuff pressure by the position changes from supine to prone and the flexion and extension of head","volume":"68","author":"Kim","year":"2015","journal-title":"Korean J Anaesthesiol."},{"key":"R12-20240828","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.bjan.2018.01.011","article-title":"Comparison of endotracheal tube cuff pressure changes using air versus nitrous oxide in anaesthetic gases during laparoscopic abdominal surgeries","volume":"68","author":"Mogal","year":"2018","journal-title":"Braz J Anaesthesiol"},{"key":"R13-20240828","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1016\/j.jmig.2012.03.019","article-title":"Trendelenburg position in gynecologic robotic-assisted surgery","volume":"19","author":"Ghomi","year":"2012","journal-title":"J Minim Invasive Gynecol"},{"key":"R14-20240828","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1016\/j.jmig.2012.03.014","article-title":"Blinded measure of Trendelenburg angle in pelvic robotic surgery","volume":"19","author":"Gould","year":"2012","journal-title":"J Minim Invasive Gynecol"},{"key":"R15-20240828","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/S1875-4597(09)60028-X","article-title":"Determining an optimal tracheal tube cuff pressure by the feel of the pilot balloon:A training course for trainees providing airway care","volume":"47","author":"Chan","year":"2009","journal-title":"Acta Anaesthesiol Taiwan"}],"container-title":["Journal of Anaesthesiology Clinical Pharmacology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/joacp.JOACP_325_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:06:45Z","timestamp":1787756805000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/joacp.JOACP_325_20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/joacp.joacp_325_20","relation":{},"ISSN":["2231-2730","0970-9185"],"issn-type":[{"value":"2231-2730","type":"print"},{"value":"0970-9185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4]]},"assertion":[{"value":"2020-06-07","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-04-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}