{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T21:55:26Z","timestamp":1789077326566,"version":"build-2803163510"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background and Aims:<\/jats:title>\n                    <jats:p>An efficient neonatal airway management is peculiarly challenging even in the most experienced hands. Considering the recent interest in assessing the performance of various video-laryngoscopes (VL) in pediatric cohort, the prospective randomized study was contemplated to stage a comparative evaluation of C-MAC with Miller laryngoscope for neonatal endotracheal intubation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and Methods:<\/jats:title>\n                    <jats:p>\n                      150 neonates were randomized to undergo intubation with either the C-MAC VL (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 75) or the Miller laryngoscope (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 75) performed by an experienced anesthesiologist in a tertiary care perioperative setting. The percentage of glottic opening (POGO), time to best glottic view (TTBGV), time to intubation (TTI), number of attempts, optimal external laryngeal manipulation (OELM) employed, and the complications were assessed and compared between the two groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      C-MAC group demonstrated a significantly higher POGO, compared to the Miller group (88 \u00b1 26.7%;76.8 \u00b1 32.1%, respectively,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.022). TTBGV was significantly lower in the C-MAC (7.7 \u00b1 0.1s) group as opposed to the Miller group (11.3 \u00b1 1.1s). The C-MAC group displayed higher TTI values compared to the Miller group (25.4 \u00b1 1.6s; 19.7 \u00b1 1.2s, respectively,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01).The first-attempt intubation success rate and the number of attempts were comparable in both the groups. OELM was required in 24% of the patients in the Miller group as opposed to 10.7% in the C-MAC group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.031).Higher patient percentage in the C-MAC group required the need of stylet for assisting a successful intubation, although the difference between the two groups was not statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Despite an improved view of the glottis, the TTI was higher for C-MAC compared to direct laryngoscopy with a comparable first-attempt success rate in the two techniques.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/joacp.joacp_422_20","type":"journal-article","created":{"date-parts":[[2022,10,11]],"date-time":"2022-10-11T11:28:33Z","timestamp":1665487713000},"page":"464-468","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["A randomized comparative evaluation of C-MAC video-laryngoscope with Miller laryngoscope for neonatal endotracheal intubation"],"prefix":"10.4103","volume":"38","author":[{"given":"Sachin","family":"Goel","sequence":"first","affiliation":[{"name":"Department of Anaesthesia and Intensive Care, Baba Kharak Singh Marg, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ripon","family":"Choudhary","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia and Intensive Care, Govind Ballabh Pant Hospital, Baba Kharak Singh Marg, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rohan","family":"Magoon","sequence":"additional","affiliation":[{"name":"Department of Cardiac Anaesthesia, Atal Bihari Vajpayee Institute of Medical Sciences (ABVIMS) and Dr. Ram Manohar Lohia Hospital, Baba Kharak Singh Marg, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ridhima","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Paediatric Anaesthesia, Postgraduate Institute of Child Health, Noida, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Usha","sequence":"additional","affiliation":[{"name":"Department of Paediatric Surgery, Vardhman Mahavir Medical College and Safdarjung Hospital, Baba Kharak Singh Marg, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Poonam M.","family":"Kapoor","sequence":"additional","affiliation":[{"name":"Department of Cardiac Anaesthesia, Cardiothoracic Centre, CNC, All India Institute of Medical Sciences, NewDelhi, Ansari Nagar, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepak","family":"Bagga","sequence":"additional","affiliation":[{"name":"Department of Paediatric Surgery, Vardhman Mahavir Medical College and Safdarjung Hospital, Baba Kharak Singh Marg, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,2,10]]},"reference":[{"key":"R1-20240828","doi-asserted-by":"crossref","first-page":"S26","DOI":"10.4103\/0971-9784.197794","article-title":"Airway management of the cardiac surgical patients:Current perspective","volume":"20","author":"Choudhury","year":"2017","journal-title":"Ann Card Anaesth"},{"key":"R2-20240828","doi-asserted-by":"crossref","first-page":"791","DOI":"10.4103\/ija.IJA_823_18","article-title":"Efficacy and safety of videolaryngoscopy-guided verbal feedback to teach neonatal and infant intubation. A prospective randomised cross over study","volume":"63","author":"Saran","year":"2019","journal-title":"Indian J Anaesth"},{"key":"R3-20240828","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1097\/00044067-199802000-00003","article-title":"Intubation complications in the critically ill child","volume":"9","author":"Page","year":"1998","journal-title":"AACN Clin Issues"},{"key":"R4-20240828","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1111\/pan.13316","article-title":"Comparison of intubation conditions with CMAC Miller videolaryngoscope and conventional Miller laryngoscope in lateral position in infants:A prospective randomized trial","volume":"28","author":"Jain","year":"2018","journal-title":"Paediatr Anaesth"},{"key":"R5-20240828","doi-asserted-by":"crossref","first-page":"284","DOI":"10.4103\/ija.IJA_753_18","article-title":"Evaluation of performance of C-MAC\u00aevideo laryngoscope Miller blade size zero for endotracheal intubation in preterm and ex-preterm infants:A retrospective analysis","volume":"63","author":"Sinha","year":"2019","journal-title":"Indian J Anaesth"},{"key":"R6-20240828","first-page":"41","article-title":"A randomised trial to compare TruviewPCD, C-MAC and Macintosh laryngoscopes in paediatric airway management. Asian J Anesthesiol","volume":"55","author":"Singh","year":"2017"},{"key":"R7-20240828","doi-asserted-by":"crossref","first-page":"1056","DOI":"10.1111\/pan.12458","article-title":"Pediatric video laryngoscope versus direct laryngoscope:A meta-analysis of randomized controlled trials","volume":"24","author":"Sun","year":"2014","journal-title":"Paediatr Anaesth"},{"key":"R8-20240828","doi-asserted-by":"crossref","first-page":"781","DOI":"10.4103\/ija.IJA_738_19","article-title":"Use of videolaryngoscopy as a teaching tool for novices performing tracheal intubation results in greater first pass success in neonates and infants","volume":"63","author":"Myatra","year":"2019","journal-title":"Indian J Anaesth"},{"key":"R9-20240828","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1542\/peds.2015-1028","article-title":"Videolaryngoscopy to teach neonatal intubation:A randomized trial","volume":"136","author":"O'Shea","year":"2015","journal-title":"Pediatrics"},{"key":"R10-20240828","first-page":"CD009975","article-title":"Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in neonates","volume":"6","author":"Lingappan","year":"2018","journal-title":"Cochrane Database Syst Rev"},{"key":"R11-20240828","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1007\/s12630-020-01585-9","article-title":"Can't see for looking:tracheal intubation using video laryngoscopes","volume":"67","author":"Hung","year":"2020","journal-title":"Can J Anaesth"},{"key":"R12-20240828","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.bja.2017.12.041","article-title":"Videolaryngoscopy versus direct laryngoscopy for emergency orotracheal intubation outside the operating room:A systematic review and meta-analysis","volume":"120","author":"Arulkumaran","year":"2018","journal-title":"Br J Anaesth"},{"key":"R13-20240828","first-page":"4196813","article-title":"Comparison of the success of two techniques for the endotracheal intubation with C-MAC video laryngoscope miller blade in children:A prospective randomized study","volume":"2016","author":"Sinha","year":"2016","journal-title":"Anesthesiol Res Pract"},{"key":"R14-20240828","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1111\/j.1460-9592.2009.03127.x","article-title":"A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway\u2013a randomized clinical trial","volume":"19","author":"Vlatten","year":"2009","journal-title":"Paediatr Anaesth"},{"key":"R15-20240828","doi-asserted-by":"crossref","first-page":"e339","DOI":"10.1542\/peds.2008-3653","article-title":"A videolaryngoscopy technique for the intubation of the newborn:Preliminary report","volume":"124","author":"Vanderhal","year":"2009","journal-title":"Pediatrics"},{"key":"R16-20240828","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1097\/SIH.0000000000000141","article-title":"Learning neonatal intubation using the videolaryngoscope:A randomized trial on mannequins","volume":"11","author":"Assaad","year":"2016","journal-title":"Simul Healthc"},{"key":"R17-20240828","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1111\/j.1460-9592.2009.03186.x","article-title":"Comparison of the intubation with the Storz video laryngoscope and standard direct laryngoscopy in paediatric patients","volume":"19","author":"Xue","year":"2009","journal-title":"Paediatr Anaesth"},{"key":"R18-20240828","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1213\/ANE.0b013e3181ad8a05","article-title":"Management of the difficult infant airway with the Storz video laryngoscope:A case series","volume":"109","author":"Hackell","year":"2009","journal-title":"Anesth Analg"},{"key":"R19-20240828","doi-asserted-by":"crossref","first-page":"500","DOI":"10.4103\/sja.SJA_199_18","article-title":"Anesthesia challenges for emergency surgery in a pediatric patient with congenital laryngomalacia","volume":"12","author":"Sharma","year":"2018","journal-title":"Saudi J Anaesth"},{"key":"R20-20240828","doi-asserted-by":"crossref","first-page":"e460","DOI":"10.1016\/j.bja.2020.08.042","article-title":"Safeguarding anaesthesia research from spin","volume":"125","author":"Magoon","year":"2020","journal-title":"Br J Anaesth"},{"key":"R21-20240828","doi-asserted-by":"crossref","first-page":"80","DOI":"10.4103\/sja.SJA_751_20","article-title":"Comment on a published article:The VL3 videolaryngoscope for tracheal intubation in adults:A prospective pilot study","volume":"15","author":"Choudhary","year":"2021","journal-title":"Saudi J Anaesth"}],"container-title":["Journal of Anaesthesiology Clinical Pharmacology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/joacp.JOACP_422_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:10:58Z","timestamp":1787757058000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/joacp.JOACP_422_20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,10]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/joacp.joacp_422_20","relation":{},"ISSN":["2231-2730","0970-9185"],"issn-type":[{"value":"2231-2730","type":"print"},{"value":"0970-9185","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,10]]},"assertion":[{"value":"2020-07-08","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-04-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}