{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T02:15:39Z","timestamp":1789092939894,"version":"build-2803163510"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To evaluate the dimensions of lower punctum in a sample of Iranian normal population using spectral domain anterior segment optical coherence tomography (OCT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this cross-sectional study, 102 eyes of 102 healthy volunteers were enrolled. All participants underwent a detailed history and complete ophthalmic examination. Lower punctum metrics were measured using OCT (Spectralis, Heidelberg) with the anterior segment module. External punctal diameter was defined as the largest diameter at the surface of the punctum. Internal punctal diameter was measured at two different depths of 100 \u03bcm and 500 \u03bcm from the external surface. Measurements were repeated for 30% of data by another grader. The agreement was measured using intraclass correlation coefficient (ICC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The mean age of the participants was 61.5 \u00b1 7.9 years. The mean external punctal diameter was 425.6 \u00b1 124.3 \u03bcm. The mean internal punctal diameter at 100 \u03bcm and 500 \u03bcm was 183 \u00b1 97.5 \u03bcm and 77.7 \u00b1 51.4 \u03bcm, respectively. The agreement between the graders was high in assessing all punctal characteristics (ICC &gt;0.9 for all measurements).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The spectral domain OCT can be used for measuring lower punctum diameter with acceptable reproducibility.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/joco.joco_131_20","type":"journal-article","created":{"date-parts":[[2021,7,15]],"date-time":"2021-07-15T06:19:19Z","timestamp":1626329959000},"page":"124-127","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Investigation of the Lower Punctum Parameters"],"prefix":"10.4103","volume":"33","author":[{"given":"Aliakbar","family":"Sabermoghaddam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shahin","family":"Golestani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kiana","family":"Hassanpour","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elham","family":"Bakhtiari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-5-20240910","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1097\/00002341-199309000-00006","article-title":"Stenotic puncta: Microsurgical punctoplasty","volume":"9","author":"Cowen","year":"1993","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"R2-5-20240910","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.2147\/OPTH.S31904","article-title":"Punctal stenosis: Definition, diagnosis, and treatment","volume":"6","author":"Soiberman","year":"2012","journal-title":"Clin Ophthalmol"},{"key":"R3-5-20240910","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1076\/orbi.17.1.27.7951","article-title":"Proximal canalicular imaging utilizing ultrasound biomicroscopy A: Normal canaliculi","volume":"17","author":"Hurwitz","year":"1998","journal-title":"Orbit"},{"key":"R4-5-20240910","doi-asserted-by":"crossref","first-page":"1446","DOI":"10.1136\/bjo.2010.195479","article-title":"Anatomical utility of ultrasound biomicroscopy in the lacrimal drainage system","volume":"95","author":"Al-Faky","year":"2011","journal-title":"Br J Ophthalmol"},{"key":"R5-5-20240910","doi-asserted-by":"crossref","first-page":"428","DOI":"10.3109\/01676830.2014.949793","article-title":"Optical coherence tomography imaging of the proximal lacrimal system","volume":"33","author":"Wawrzynski","year":"2014","journal-title":"Orbit"},{"key":"R6-5-20240910","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1016\/S0002-9394(03)00664-0","article-title":"Acquired external punctal stenosis: Etiology and associated findings","volume":"136","author":"Kashkouli","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R7-5-20240910","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1097\/01.iop.0000231773.20993.79","article-title":"A permanent and reversible procedure to block tear drainage for the treatment of dry eye","volume":"22","author":"DeMartelaere","year":"2006","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"R8-5-20240910","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1159\/000074561","article-title":"20-MHz ultrasoundand its value in imaging of lacrimal plugs","volume":"218","author":"Tost","year":"2004","journal-title":"Ophthalmologica"},{"key":"R9-5-20240910","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1259\/0007-1285-66-788-711","article-title":"Technical note: Computed tomographic dacryocystography","volume":"66","author":"Waite","year":"1993","journal-title":"Br J Radiol"},{"key":"R11-5-20240910","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1111\/j.1442-9071.2008.01823.x","article-title":"Clinical and research applications of anterior segment optical coherence tomography","volume":"37","author":"Ramos","year":"2009","journal-title":"A review. Clin Exp Ophthalmol"},{"key":"R12-5-20240910","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1016\/j.ophtha.2017.01.054","article-title":"The application of infrared imaging and optical coherence tomography of the lacrimal punctum in patients undergoing punctoplasty for epiphora","volume":"124","author":"Timlin","year":"2017","journal-title":"Ophthalmology"},{"key":"R13-5-20240910","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/IOP.0000000000000396","article-title":"Fourier domain optical coherence tomography with 3D and en face imaging of the punctum and vertical canaliculus: A step toward establishing a normative database","volume":"32","author":"Kamal","year":"2016","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"R14-5-20240910","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1080\/01676830.2017.1337163","article-title":"Imaging of proximal lacrimal system with time domain anterior segment optical coherence tomography in Asian Indian population","volume":"36","author":"Singh","year":"2017","journal-title":"Orbit"}],"container-title":["Journal of Current Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/JOCO.JOCO_131_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:28:12Z","timestamp":1786735692000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/JOCO.JOCO_131_20"}},"subtitle":["A Spectral Domain Anterior Segment Optical Coherence Tomography Study"],"short-title":[],"issued":{"date-parts":[[2021,4]]},"references-count":13,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/joco.joco_131_20","relation":{},"ISSN":["2452-2325"],"issn-type":[{"value":"2452-2325","type":"print"}],"subject":[],"published":{"date-parts":[[2021,4]]}}}