{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:30:13Z","timestamp":1787070613151,"version":"build-2736575974"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess the agreement between biometric parameters measured by a spectral-domain optical coherence tomography optical biometer device (Optopol Revo NX) with a validated swept-source biometer (IOLMaster 700) and a validated optical low-coherence reflectometry biometer (Lenstar LS 900), in cataract surgery candidates.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective comparative study, 100 patients (100 eyes) who were eligible for cataract surgery were involved. Bland\u2013Altman plots were used to assess agreement between devices for biometric parameters including axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>AL measurements were successful in 82 eyes (82.0%) with Revo NX, in 91 eyes (91.0%) with Lenstar LS 900, and in 97 eyes (97.0%) with IOLMaster 700. When Revo NX was compared to IOL Master 700 and Lenstar LS 900, the mean differences were as follows: \u22120.02 \u00b1 0.02 mm and \u22120.02 \u00b1 0.03 mm (P = 0.313, P = 0.525) for AL, 0.01 \u00b1 0.03 mm and 0.10 \u00b1 0.03 mm (P = 0.691, P = 0.002) for ACD, \u22120.15 \u00b1 0.03 mm and 0.001 \u00b1 0.04 mm (P &lt; 0.001, P = 0.95) for LT, and \u22122.29 \u00b1 0.92 \u03bcm, and 0.73 \u00b1 1.43 \u03bcm (P = 0.015, P = 0.612) for CCT. Three devices were highly correlated for AL, ACD, LT, and CCT (interclass correlation coefficient &gt; 0.75). Bland\u2013Altman plots showed a narrower 95% limit of agreement (\u22120.35 to 0.31) between Revo NX and IOLMaster 700 in measuring AL.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Despite the higher measurement failure rate in eyes with cataract, the Revo NX showed very good agreement with the IOLMaster 700 and Lenstar LS 900 optical biometers in measuring AL, ACD, LT, and CCT. However, ACD and LT measurements cannot be considered interchangeable between these devices.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/joco.joco_30_23","type":"journal-article","created":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T18:32:19Z","timestamp":1717266739000},"page":"153-158","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Agreement between a Spectral-Domain Ocular Coherence Tomography Biometer with a Swept-Source Ocular Coherence Tomography Biometer and an Optical Low-Coherence Reflectometry Biometer in Eyes with Cataract"],"prefix":"10.4103","volume":"35","author":[{"given":"Siamak","family":"Zarei-Ghanavati","sequence":"first","affiliation":[{"name":"Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Majid","family":"Nikpayam","sequence":"additional","affiliation":[{"name":"Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maral","family":"Namdari","sequence":"additional","affiliation":[{"name":"Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elham","family":"Bakhtiari","sequence":"additional","affiliation":[{"name":"Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samira","family":"Hassanzadeh","sequence":"additional","affiliation":[{"name":"Department of Optometry, Refractive Error Research Center, Paramedical College, Mashhad University of Medical Sciences, Mashhad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammed","family":"Ziaei","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,12,21]]},"reference":[{"key":"R1-20240910","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","article-title":"The Hoffer Q formula: A comparison of theoretic and regression formulas","volume":"19","author":"Hoffer","year":"1993","journal-title":"J Cataract Refract Surg"},{"key":"R2-20240910","doi-asserted-by":"crossref","first-page":"1233","DOI":"10.1016\/S0886-3350(00)00376-X","article-title":"Clinical results using the Holladay 2 intraocular lens power formula","volume":"26","author":"Hoffer","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R3-20240910","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1097\/j.jcrs.0000000000000541","article-title":"Comparison of an upgraded optical biometer with 2 validated optical biometers","volume":"47","author":"Kanclerz","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R4-20240910","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/j.jcrs.2016.07.013","article-title":"Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry","volume":"42","author":"Hoffer","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R5-20240910","doi-asserted-by":"crossref","first-page":"1619","DOI":"10.1016\/j.jcrs.2019.07.002","article-title":"Repeatability and reproducibility of optical biometry implemented in a new optical coherence tomographer and comparison with a optical low-coherence reflectometer","volume":"45","author":"Kanclerz","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R6-20240910","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1097\/j.jcrs.0000000000000494","article-title":"Repeatability of biometry measured by three devices and its impact on predicted intraocular lens power","volume":"47","author":"Shetty","year":"2021","journal-title":"J Cataract Refract Surg"},{"key":"R7-20240910","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1038\/eye.2016.241","article-title":"Agreement and clinical comparison between a new swept-source optical coherence tomography-based optical biometer and an optical low-coherence reflectometry biometer","volume":"31","author":"Arriola-Villalobos","year":"2017","journal-title":"Eye (Lond)"},{"key":"R8-20240910","doi-asserted-by":"crossref","first-page":"126","DOI":"10.3341\/kjo.2019.0102","article-title":"Comparison of ocular biometry and refractive outcomes using IOL Master 500, IOL Master 700, and Lenstar LS900","volume":"34","author":"Song","year":"2020","journal-title":"Korean J Ophthalmol"},{"key":"R9-20240910","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1111\/cxo.12880","article-title":"Optical biometry in a commercially available anterior and posterior segment optical coherence tomography device","volume":"102","author":"Kanclerz","year":"2019","journal-title":"Clin Exp Optom"},{"key":"R10-20240910","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","article-title":"The lens opacities classification system III. The longitudinal study of cataract study group","volume":"111","author":"Chylack","year":"1993","journal-title":"Arch Ophthalmol"},{"key":"R11-20240910","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1016\/j.jcrs.2009.11.007","article-title":"Comparison of 2 laser instruments for measuring axial length","volume":"36","author":"Hoffer","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R12-20240910","first-page":"9192456","article-title":"OCT biometry (B-OCT): A new method for measuring ocular axial dimensions","author":"Sikorski","year":"2019","journal-title":"J Ophthalmol 2019"},{"key":"R13-20240910","doi-asserted-by":"crossref","first-page":"115","DOI":"10.3928\/1081597X-20190109-01","article-title":"Comprehensive comparison of axial length measurement with three swept-source OCT-based biometers and partial coherence interferometry","volume":"35","author":"Huang","year":"2019","journal-title":"J Refract Surg"},{"key":"R14-20240910","doi-asserted-by":"crossref","first-page":"472","DOI":"10.1111\/j.1755-3768.2007.00879.x","article-title":"Calculation of intraocular lens power: A review","volume":"85","author":"Olsen","year":"2007","journal-title":"Acta Ophthalmol Scand"},{"key":"R15-20240910","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1097\/j.jcrs.0000000000000942","article-title":"Agreement between two swept-source ocular coherence tomography biometry devices","volume":"48","author":"McLintock","year":"2022","journal-title":"J Cataract Refract Surg"}],"container-title":["Journal of Current Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/joco.joco_30_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:32:34Z","timestamp":1787067154000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/joco.joco_30_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/joco.joco_30_23","relation":{},"ISSN":["2452-2325"],"issn-type":[{"value":"2452-2325","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4]]},"assertion":[{"value":"2023-01-28","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-05-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}