{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:26:20Z","timestamp":1787840780780,"version":"build-2784847793"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 5","license":[{"start":{"date-parts":[[2024,12,1]],"date-time":"2024-12-01T00:00:00Z","timestamp":1733011200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,12]]},"abstract":"<jats:title>\n                    A\n                    <jats:sc>BSTRACT<\/jats:sc>\n                  <\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>\n                      The primary rationale of the study is to assess the biomechanical aspects of Champy\u2019s, monoplanar, biplanar, and 3D strut plating systems using an\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      model in the management of the angle of mandible fracture.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Thirty-two hemi-sectioned mandibles (\n                      <jats:italic toggle=\"yes\">N<\/jats:italic>\n                      = 32) were obtained from adult goats and divided into four groups (\n                      <jats:italic toggle=\"yes\">N<\/jats:italic>\n                      = 8) for different plating techniques: monoplanar, biplanar, Champy\u2019s, and three-dimensional curved angle strut plating. A customized biomechanical test machine simulated masticatory loads by applying compressive forces. Force versus displacement data were recorded using an Instron Lloyd LRX machine.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Plating techniques with two plates exhibited higher resistance to displacement than single-plate techniques. The three-dimensional curved angle strut plate group had the highest mean compressive strength (184.7913 N), followed by biplanar plating (170.29 N), monoplanar plating (159.3419 N), and Champy\u2019s plating (55.48375 N). Statistical analysis showed significant differences between the three-dimensional curved angle strut plating technique and Champy\u2019s plating technique (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      value \u2264 0.0016*), as well as between the biplanar plating technique and Champy\u2019s plating technique (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      value \u2264 0.0010*).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The three-dimensional curved angle strut plate and biplanar plating techniques exhibited superior biomechanical performance compared to monoplanar and Champy\u2019s plating techniques.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jpbs.jpbs_1285_24","type":"journal-article","created":{"date-parts":[[2025,1,30]],"date-time":"2025-01-30T11:04:29Z","timestamp":1738235069000},"page":"S4821-S4825","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Decoding Mandibular Angle Fracture Management: Biomechanical Analysis of Different Plating Techniques \u2013 An In Vitro Study"],"prefix":"10.4103","volume":"16","author":[{"given":"Adalarasan","family":"Subramanian","sequence":"first","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thiruneelakandan","family":"Sambanthan","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akash","family":"Punithan","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S Meera","family":"Petchiammal","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R. Bhuvana","family":"Laxmi","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vishal","family":"Srikanth","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E","family":"Eswar","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Government Dental College and Hospital, Cuddalore, Tamil Nadu, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,1,30]]},"reference":[{"key":"R1-20250130","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1055\/s-0037-1601374","article-title":"Mandible fractures","volume":"31","author":"Pickrell","year":"2017","journal-title":"Semin Plast Surg"},{"key":"R2-20250130","first-page":"12519","article-title":"A prospective randomized clinical trial comparing 3-dimensional and standard miniplate in the treatment of mandibular symphysis and parasymphysis fractures","volume":"8","author":"Changmai","year":"2021","journal-title":"NVEO-Nat Vol Essent Oi"},{"key":"R3-20250130","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/S0278-2391(82)80011-6","article-title":"Fractures of the mandible:A review of 580 cases","volume":"40","author":"Olson","year":"1982","journal-title":"J Oral Maxillofac Surg"},{"key":"R4-20250130","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/0278-2391(91)90340-R","article-title":"Infection after rigid internal fixation of mandibular fractures:A clinical and radiologic study","volume":"49","author":"Iizuka","year":"1991","journal-title":"J Oral Maxillofac Surg"},{"key":"R5-20250130","first-page":"285","article-title":"Mechanical properties of cortical and trabecular bone","volume":"7","author":"Keaveny","year":"1993","journal-title":"Bone"},{"key":"R6-20250130","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1002\/ajpa.10121","article-title":"Variations in cortical material properties throughout the human dentate mandible","volume":"120","author":"Schwartz-Dabney","year":"2003","journal-title":"Am J Phys Anthropol"},{"key":"R7-20250130","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/0021-9290(85)90045-4","article-title":"Anisotropic yield behavior of bone under combined axial force and torque","volume":"18","author":"Cezayirlioglu","year":"1985","journal-title":"J Biomech"},{"key":"R9-20250130","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1016\/0022-3913(71)90085-0","article-title":"Functional movements of the mandible","volume":"26","author":"Gibbs","year":"1971","journal-title":"J Prosthet Dent"},{"key":"R10-20250130","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.joms.2004.03.018","article-title":"Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate","volume":"63","author":"Guimond","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"R11-20250130","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/S0301-0503(73)80017-7","article-title":"Osteosynthesis with miniaturized screwed plates in maxillo-facial surgery","volume":"1","author":"Michelet","year":"1973","journal-title":"J Maxillofac Surg"},{"key":"R13-20250130","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/j.tripleo.2007.03.014","article-title":"Biomechanical comparison of different plating techniques in repair of mandibular angle fractures","volume":"104","author":"Alkan","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R14-20250130","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.tripleo.2006.12.016","article-title":"Evaluation of different miniplates in fixation of fractured human mandible with the finite element method","volume":"103","author":"Korkmaz","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R15-20250130","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1055\/s-0034-1371002","article-title":"Evaluation of 2.0-mm titanium three-dimensional curved angle strut plate in the fixation of mandibular angle fractures-A prospective clinical and radiological analysis","volume":"7","author":"Chhabaria","year":"2014","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"R16-20250130","doi-asserted-by":"crossref","first-page":"1218","DOI":"10.1097\/00005537-199808000-00022","article-title":"Plating techniques and plate orientation in repair of mandibular angle fractures:An in vitro study","volume":"108","author":"Fedok","year":"1998","journal-title":"Laryngoscope"}],"container-title":["Journal of Pharmacy and Bioallied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_1285_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:28:51Z","timestamp":1787837331000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_1285_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12]]},"references-count":14,"journal-issue":{"issue":"Suppl 5","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jpbs.jpbs_1285_24","relation":{},"ISSN":["0976-4879","0975-7406"],"issn-type":[{"value":"0976-4879","type":"print"},{"value":"0975-7406","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12]]},"assertion":[{"value":"2024-09-12","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-10-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}