{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:27:45Z","timestamp":1787758065740,"version":"build-2784847793"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>This study aims to evaluate the efficacy of resorbable plates for the fixation of mandible fracture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      10 cases of fracture mandible were treated with resorbable plates using the Inion CPS system. Patients were evaluated during their entire hospital stay and recalled on 1\n                      <jats:sup>st<\/jats:sup>\n                      , 4\n                      <jats:sup>th<\/jats:sup>\n                      , and 8\n                      <jats:sup>th<\/jats:sup>\n                      postoperative weeks. A thorough evaluation was done at the recall visits for any surgical and postoperative complications such as infection, malocclusion, neural abnormalities, wound or suture dehiscence, segmental mobility, foreign body reaction, and pain on biting. Bite force measurements were taken to evaluate the return of function.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Clinical union of the fracture was noted at the 8\n                      <jats:sup>th<\/jats:sup>\n                      week follow-up examination for all cases. There were swelling and pain at the operated site at 8\n                      <jats:sup>th<\/jats:sup>\n                      week follow-up for one patient, which was managed conservatively. The mean bite force was recorded for different regions and it increased over the entire follow-up period progressively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>These plates and screws are an essential tool in the treatment of mandibular fractures owing to benefits such as biodegradability, biocompatibility, and the ability to be eliminated via the body's natural processes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jpbs.jpbs_22_22","type":"journal-article","created":{"date-parts":[[2022,7,13]],"date-time":"2022-07-13T15:05:34Z","timestamp":1657724734000},"page":"S845-S849","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Experience with Resorbable Plates for Fixation of Mandible Fracture. A Prospective Study of 10 Cases"],"prefix":"10.4103","volume":"14","author":[{"given":"Atul","family":"Singh","sequence":"first","affiliation":[{"name":"Department of Dentistry, Dr. Yashwant Singh Parmar Government Medical College, Nahan, Himachal Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Muthunagai","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Seema Dental College and Hospital, Rishikesh, Uttrakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mudit","family":"Agarwal","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Seema Dental College and Hospital, Rishikesh, Uttrakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ranjita","family":"Mehta","sequence":"additional","affiliation":[{"name":"Department of Oral Medicine and Radiology, Seema Dental College and Hospital, Rishikesh, Uttrakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Karpagavalli","sequence":"additional","affiliation":[{"name":"Department of Oral Medicine and Radiology, Seema Dental College and Hospital, Rishikesh, Uttrakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shailja","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Oral Pathology, Seema Dental College and Hospital, Rishikesh, Uttrakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G. Arun","family":"Prasad","sequence":"additional","affiliation":[{"name":"Oral & Maxillofacial Surgeon, Private practice, GS Dental Care, Saram, Puducherry, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,7,13]]},"reference":[{"key":"R1-20250925","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1097\/00006534-199803000-00004","article-title":"Biomechanical evaluation of titanium, biodegradable plate and screw, and cyanoacrylate glue fixation systems in craniofacial surgery","volume":"101","author":"Gosain","year":"1998","journal-title":"Plast Reconstr Surg"},{"key":"R2-20250925","first-page":"38 41","article-title":"Re: Wood GD, Inion biodegradable plates: The first century","volume":"44","author":"Whitley","year":"2006","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R3-20250925","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s00238-003-0568-8","article-title":"New resorbable bone fixation. Biomaterials in craniomaxillofacial surgery: Present and future","volume":"26","author":"Ashammakhi","year":"2004","journal-title":"Eur J Plast Surg"},{"key":"R4-20250925","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1097\/SCS.0b013e31819922fb","article-title":"Use of resorbable implants for mandibular fixation: A systematic review","volume":"20","author":"Agarwal","year":"2009","journal-title":"J Craniofac Surg"},{"key":"R5-20250925","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1001\/archsurg.1966.01330050143023","article-title":"Polylactic acid for surgical implants","volume":"93","author":"Kulkarni","year":"1966","journal-title":"Arch Surg"},{"key":"R6-20250925","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.jobcr.2015.09.004","article-title":"Management of pediatric mandibular fractures using bioresorbable plating system \u2013 Efficacy, stability, and clinical outcomes: Our experiences and literature review","volume":"6","author":"Singh","year":"2016","journal-title":"J Oral Biol Craniofac Res"},{"key":"R7-20250925","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.jdsr.2018.03.003","article-title":"Overview of innovative advances in bioresorbable plate systems for oral and maxillofacial surgery","volume":"54","author":"Kanno","year":"2018","journal-title":"Jpn Dent Sci Rev"},{"key":"R8-20250925","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/S0901-5027(05)80358-3","article-title":"Biodegradable fracture-fixation devices in maxillofacial surgery","volume":"22","author":"Suuronen","year":"1993","journal-title":"Int J Oral Maxillofac Surg"},{"key":"R9-20250925","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1016\/S0278-2391(97)90065-3","article-title":"A bioabsorbable poly-L-lactide miniplate and screw system for osteosynthesis in oral and maxillofacial surgery","volume":"55","author":"Bessho","year":"1997","journal-title":"J Oral Maxillofac Surg"},{"key":"R10-20250925","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1016\/S0278-2391(10)80267-8","article-title":"Foreign body reactions to resorbable poly (L-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures","volume":"51","author":"Bergsma","year":"1993","journal-title":"J Oral Maxillofac Surg"},{"key":"R11-20250925","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/0278-2391(87)90194-7","article-title":"Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures","volume":"45","author":"Bos","year":"1987","journal-title":"J Oral Maxillofac Surg"},{"key":"R12-20250925","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1016\/S0266-4356(97)90716-6","article-title":"The use of biodegradable fixation in sagittal split and vertical subsigmoid osteotomy of the mandible: A preliminary report","volume":"35","author":"McManners","year":"1997","journal-title":"Br J Oral Maxillofac Surg"},{"key":"R13-20250925","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1016\/S0278-2391(98)90461-X","article-title":"A 5-year in vitro and in vivo study of the biodegradation of polylactide plates","volume":"56","author":"Suuronen","year":"1998","journal-title":"J Oral Maxillofac Surg"},{"key":"R14-20250925","first-page":"43","article-title":"Resorbable plate-screw systems: Clinical applications","volume":"11","author":"Cavu\u015fo\u011flu","year":"2005","journal-title":"Ulus Travma Acil Cerrahi Derg"},{"key":"R15-20250925","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/j.joms.2005.10.055","article-title":"Resorbable plates for the fixation of mandibular fractures: A prospective study","volume":"65","author":"Laughlin","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"R16-20250925","doi-asserted-by":"crossref","first-page":"219","DOI":"10.2485\/jhtb.24.219","article-title":"Long-term bioresorption of bone fixation devices made from composites of unsintered hydroxyapatite particles and poly-L-lactide","volume":"24","author":"Sukegawa","year":"2015","journal-title":"J Hard Tissue Biol"},{"key":"R17-20250925","doi-asserted-by":"crossref","first-page":"e0130330","DOI":"10.1371\/journal.pone.0130330","article-title":"Cost-effectiveness of a biodegradable compared to a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial","volume":"10","author":"van Bakelen","year":"2015","journal-title":"PLoS One"}],"container-title":["Journal of Pharmacy and Bioallied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_22_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:03:04Z","timestamp":1787756584000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_22_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7]]},"references-count":17,"journal-issue":{"issue":"Suppl 1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/jpbs.jpbs_22_22","relation":{},"ISSN":["0976-4879","0975-7406"],"issn-type":[{"value":"0976-4879","type":"print"},{"value":"0975-7406","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7]]},"assertion":[{"value":"2022-01-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-01-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}