{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:36:02Z","timestamp":1787841362848,"version":"build-2784847793"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,11]]},"abstract":"<jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>Sterilization of impression materials is of paramount importance. The present study was conducted to compare the effect of different disinfectants on dimensional accuracy of elastomeric impression materials used for implant prosthesis and other routine treatments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>The present study was conducted with polyvinyl siloxane (PVS) (regular body), PVS (medium body), PVS (heavy body), and polyether (medium body) impression materials. Glutaraldehyde (2%) and sodium hypochlorite (NaOCl, 0.525%) were the disinfectant solutions employed in the study. After 16 h, the specimens were measured under Leica WILD stereomicroscope and dimensions were compared with master die.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The dimensional change in the Controls, 2% glutaraldehyde (Group I), and 0.525% NaOCl (Group II) was non significant where as Group III and Group IV showed statistically significant difference (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). Results also showed significantly higher tear strength (newton\/millimeter) in Control group followed by Group I and Group II.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>PVS (heavy body) was found to be most stable, and polyether was seen to be stable of all the impression materials.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jpbs.jpbs_315_21","type":"journal-article","created":{"date-parts":[[2023,2,8]],"date-time":"2023-02-08T06:05:28Z","timestamp":1675836328000},"page":"S1620-S1623","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis \u2013 An In vitro Study"],"prefix":"10.4103","volume":"13","author":[{"given":"Kumari","family":"Kavita","sequence":"first","affiliation":[{"name":"Department of Dentistry, Nalanda Medical College and Hospital, Patna, Bihar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. R. Parameshwar","family":"Reddy","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Malla Reddy Institute of Dental Sciences, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K. R. Maheshwar","family":"Reddy","sequence":"additional","affiliation":[{"name":"Pediatric Dentistry, Rushi Dental Care, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Swatantra","family":"Kumar","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Crown Bridge and Implantology, Awadh Dental College and Hospital, Jamshedpur, Jharkhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gyanendra","family":"Pandey","sequence":"additional","affiliation":[{"name":"Department of Oral Medicine Radiology and Diagnosis, Purvanchal institute of Dental Sciences, Gorakhpur, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Revati","family":"Singh","sequence":"additional","affiliation":[{"name":"Department of Dentistry, Patna Medical College and Hospital, Patna, Bihar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,11,10]]},"reference":[{"key":"R1-20250920","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1111\/j.1532-849X.2007.00206.x","article-title":"Surface quality and longterm dimensional stability of current elastomeric impression materials after disinfection","volume":"16","author":"Walker","year":"2007","journal-title":"J Prosthodont"},{"key":"R2-20250920","first-page":"35","article-title":"Dimensional stability of autoclave sterilised addition cured impressions and trays","volume":"22","author":"Deb","year":"2014","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"R3-20250920","doi-asserted-by":"crossref","first-page":"518","DOI":"10.4236\/ojst.2014.412069","article-title":"Effect of autoclave sterilisation on the dimensional stability and tear strength of three silicone impression materials","volume":"4","author":"Millar","year":"2014","journal-title":"Open J Stomatol"},{"key":"R4-20250920","doi-asserted-by":"crossref","first-page":"152","DOI":"10.4103\/jispcd.JISPCD_406_18","article-title":"Comparative Evaluation of the effect of chemical disinfectants and ultraviolet disinfection on dimensional stability of the polyvinyl siloxane impressions","volume":"9","author":"Nimonkar","year":"2019","journal-title":"J Int Soc Prev Community Dent"},{"key":"R5-20250920","doi-asserted-by":"crossref","first-page":"63","DOI":"10.11607\/ijp.4358","article-title":"Effectiveness of disinfectants on antimicrobial and physical properties of dental impression materials","volume":"29","author":"Demajo","year":"2016","journal-title":"Int J Prosthodont"},{"key":"R6-20250920","doi-asserted-by":"crossref","first-page":"e849","DOI":"10.1111\/jopr.12597","article-title":"Comprehensive review and comparison of the disinfection techniques currently available in the literature","volume":"28","author":"Chidambaranathan","year":"2019","journal-title":"J Prosthodont"},{"key":"R7-20250920","doi-asserted-by":"crossref","first-page":"131","DOI":"10.4103\/0972-4052.155034","article-title":"An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization","volume":"15","author":"Khinnavar","year":"2015","journal-title":"J Indian Prosthodont Soc"},{"key":"R8-20250920","first-page":"69","article-title":"A comparison of dimensional accuracy between three different addition cured silicone impression materials","volume":"13","author":"Forrester-Baker","year":"2005","journal-title":"Eur J Prosthodont Restor Dent"},{"key":"R9-20250920","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/S0022-3913(99)70219-2","article-title":"Effect of disinfectant agents on dimensional stability of elastomeric impression materials","volume":"81","author":"Adabo","year":"1999","journal-title":"J Prosthet Dent"},{"key":"R10-20250920","first-page":"695151","article-title":"The effect of three different disinfection materials on alginate impression by spray method","volume":"2012","author":"Badrian","year":"2012","journal-title":"ISRN Dent"},{"key":"R11-20250920","doi-asserted-by":"crossref","first-page":"33","DOI":"10.4103\/jips.jips_72_18","article-title":"Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions","volume":"19","author":"Mahalakshmi","year":"2019","journal-title":"J Indian Prosthodont Soc"}],"container-title":["Journal of Pharmacy and Bioallied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_315_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:51:47Z","timestamp":1787838707000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_315_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11]]},"references-count":11,"journal-issue":{"issue":"Suppl 2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/jpbs.jpbs_315_21","relation":{},"ISSN":["0976-4879","0975-7406"],"issn-type":[{"value":"0976-4879","type":"print"},{"value":"0975-7406","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11]]},"assertion":[{"value":"2021-04-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-05-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}