{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:34:12Z","timestamp":1787762052309,"version":"build-2784847793"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>\n                    A\n                    <jats:sc>BSTRACT<\/jats:sc>\n                  <\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>\n                      With the advent of mini-implants, Class II correction has become routine. The study\u2019s goal was to compare the \u201c\n                      <jats:italic toggle=\"yes\">Bone-Anchored Pendulum Appliance<\/jats:italic>\n                      (\n                      <jats:italic toggle=\"yes\">BAPA<\/jats:italic>\n                      )\u201d to the \u201c\n                      <jats:italic toggle=\"yes\">Bone-Anchored Intraoral Bodily Molar Distalizer (BAIBMD)<\/jats:italic>\n                      \u201d in terms of clinical efficacy.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Procedures:<\/jats:title>\n                    <jats:p>Five boys and five girls were among the 10 patients in this split-mouth trial who had to have their molars distalized. On one side, BAPA Construction, and on the other, BAIBMD was piloted. A titanium mini-screw was used to secure both appliances to the bone since this was a spilled-mouth technique. The first molar bands to apply 200 g of force were used for both devices, as with all the other components that were similar for both appliances. For both sides, the nature, duration, and rate of tooth movement were compared. Using the Wilcoxon signed-rank test, descriptive statistics for several parameters were examined.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Distalization was accomplished on both sides with clinical success. The rate of distalization did not show any significant variation. Less time was needed for distalization with BAPA, as evidenced by the statistically substantial variances in treatment duration between the two groups. Molar tipping was noticed in BAPA, and it was statistically significant.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>While the pace of distalization was equal for both appliances, BAIBMD required more time than BAPA but resulted in a distal tooth movement that was mostly translatory in nature.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jpbs.jpbs_446_22","type":"journal-article","created":{"date-parts":[[2023,7,12]],"date-time":"2023-07-12T02:07:24Z","timestamp":1689127644000},"page":"S166-S170","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of the Bone-Anchored Pendulum Appliance and the Bone-Anchored Intraoral Bodily Molar Distalizer: An Original Research"],"prefix":"10.4103","volume":"15","author":[{"given":"John","family":"Patowary","sequence":"first","affiliation":[{"name":"Department of Orthodontics and Dentofacial Orthopaedics, Regional Dental College, Bhangagarh, Guwahati, Assam, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pranay","family":"Kumar","sequence":"additional","affiliation":[{"name":"Department of Orthodontics and Dentofacial Orthopedics, Maharaja Ganga Singh Dental College and Research Centre, Ganganagar, Rajasthan, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C V Padma","family":"Priya","sequence":"additional","affiliation":[{"name":"Department of Orthodontics and Dentofacial Orthopedics, Vishnu Dental College, Bhimavaram, Andhra Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bushra","family":"Kanwal","sequence":"additional","affiliation":[{"name":"Specialist Orthodontist, Rawa Almas Splendid Diamond Clinic, Al Baha, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Afreen","family":"Kauser","sequence":"additional","affiliation":[{"name":"Department of Orthodontics and Dentofacial Orthopeadics, College of Dental Sciences, Davangere, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prince K.","family":"Chacko","sequence":"additional","affiliation":[{"name":"Department of Orthodontics and Dentofacial Orthopedics, Educare Institute of Dental Sciences, Chattiparambu, Malappuram, Kerala, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,7,5]]},"reference":[{"key":"R1-20240829","first-page":"700","article-title":"The pendulum appliance for Class II non-compliance therapy","volume":"26","author":"Hilgers","year":"1992","journal-title":"J Clin Orthod"},{"key":"R2-20240829","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/S0889-5406(00)70246-0","article-title":"A new approach in maxillary molar distalization:Intraoral bodily molar distalizer","volume":"117","author":"Keles","year":"2000","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R3-20240829","first-page":"763","article-title":"Mini-implant for orthodontic anchorage","volume":"31","author":"Konomi","year":"1997","journal-title":"J Clin Orthod"},{"key":"R4-20240829","first-page":"650","article-title":"Maxillary molar distalization with a bone-anchored pendulum appliance","volume":"76","author":"Kircelli","year":"2006","journal-title":"Angle Orthod"},{"key":"R5-20240829","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.ajodo.2006.08.012","article-title":"Distalization of maxillary molars with the bone-supported-pendulum:A clinical study","volume":"131","author":"Escobar","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R6-20240829","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1016\/j.ajodo.2005.02.034","article-title":"Osseointegrated implants with pendulum springs for maxillary molar distalization:A cephalometric study","volume":"131","author":"Oncag","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R7-20240829","doi-asserted-by":"crossref","first-page":"339.e9","DOI":"10.1016\/j.ajodo.2007.10.002","article-title":"Pendulum appliances with 2 anchorage designs:Conventional anchorage versus bone anchorage","volume":"133","author":"Polat-Ozsoy","year":"2008","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R8-20240829","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1016\/j.ajodo.2008.07.027","article-title":"Molar distalization with a partially integrated mini-implant to correct unilateral Class II malocclusion","volume":"138","author":"Chung","year":"2010","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R9-20240829","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1007\/s00056-013-0189-1","article-title":"Upper molar distalization with skeletally anchored TopJet appliance","volume":"75","author":"Pseiner","year":"2014","journal-title":"J Orofac Orthop"},{"key":"R10-20240829","doi-asserted-by":"crossref","first-page":"161.e1","DOI":"10.1016\/j.ajodo.2006.03.027","article-title":"Comparison of 2 distalization systems supported by intraosseous screws","volume":"131","author":"Gelgor","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R11-20240829","first-page":"331","article-title":"Application and effectiveness of the Benslider:A devise to move molars distally","volume":"11","author":"Wilmes","year":"2010","journal-title":"World J Orthod"},{"key":"R12-20240829","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1053\/od.2000.5901","article-title":"An evaluation of the pendulum distalizing appliance","volume":"6","author":"Joseph","year":"2000","journal-title":"Semin Orthod"},{"key":"R13-20240829","first-page":"282.e1","article-title":"Maxillary molar distalization with the dual-force distalizer supported by mini-implants:A clinical study","volume":"135","author":"Obeti","year":"2009","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R14-20240829","first-page":"249","article-title":"Distal molar movement using the pendulum appliance. Part 1:Clinical and radiological evaluation","volume":"67","author":"Byloff","year":"1997","journal-title":"Angle Orthod"},{"key":"R15-20240829","first-page":"374","article-title":"The distal jet for upper molar distalization","volume":"30","author":"Carano","year":"1996","journal-title":"J Clin Orthod"},{"key":"R16-20240829","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1067\/mod.2001.114645","article-title":"Posttreatment evaluation of the distal jet appliance","volume":"20","author":"Ngantung","year":"2001","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R17-20240829","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.ajodo.2011.01.019","article-title":"Are orthodontic distalizers reinforced with the temporary skeletal anchorage devices effective?","volume":"139","author":"Fudalej","year":"2011","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"R18-20240829","doi-asserted-by":"crossref","first-page":"141","DOI":"10.4103\/jos.JOS_66_17","article-title":"Changes consequent to maxillary molar distalization with the bone-anchored pendulum appliance","volume":"6","author":"Cambiano","year":"2017","journal-title":"J Orthodont Sci"}],"container-title":["Journal of Pharmacy and Bioallied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_446_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:14:39Z","timestamp":1787760879000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_446_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":18,"journal-issue":{"issue":"Suppl 1","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/jpbs.jpbs_446_22","relation":{},"ISSN":["0976-4879","0975-7406"],"issn-type":[{"value":"0976-4879","type":"print"},{"value":"0975-7406","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7]]},"assertion":[{"value":"2022-10-03","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-11-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}