{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:19:35Z","timestamp":1787771975976,"version":"build-2784847793"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:title>\n                    A\n                    <jats:sc>BSTRACT<\/jats:sc>\n                  <\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>\n                      <jats:italic toggle=\"yes\">Obstructive sleep apnea<\/jats:italic>\n                      , often known as OSA, is a sleep-related breathing disease that, if not treated, can lead to serious disabilities or even death.\n                      <jats:italic toggle=\"yes\">Continuous positive airway pressure<\/jats:italic>\n                      (CPAP) is the therapy technique that is suggested for treating severe and moderate OSA. An auto\/manual CPAP titration study can be used to determine the appropriate pressure that must be maintained to treat this condition. The motive of this research is to appraise the effectiveness among OSA patients for the auto-PAP titrations.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methodology:<\/jats:title>\n                    <jats:p>A cross-sectional clinical prospective study was conducted at the tertiary care center. Subjects who underwent auto-PAP titration and had a diagnosis of moderate and sever OSA were included. They were evaluated for the efficacy of auto-PAP titration and other demographic features and their association with the titration efficacy. The values were compared for statistical significance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The findings of the study showed that fifty percent of the cohort showed optimal titration, forty percent showed good titration, ten percent showed suitable titration, and none fell into the unacceptable group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>According to the findings, using auto-PAP was associated with positive results in those with moderate and severe OSA. There is evidence to suggest that unattended auto-PAP titration is a very successful technique that might be regarded as a substitute for attended CPAP titrations. This would result in a reduction in the amount of labor required and the price.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jpbs.jpbs_501_23","type":"journal-article","created":{"date-parts":[[2024,2,29]],"date-time":"2024-02-29T15:07:24Z","timestamp":1709219244000},"page":"S302-S304","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Auto-PAP Titration Efficacy in Obstructive Sleep Apnea: A Single-Center Experience"],"prefix":"10.4103","volume":"16","author":[{"given":"Sanjay D.","family":"Gabhale","sequence":"first","affiliation":[{"name":"Department of Respiratory Medicine, Dr D. Y. Patil Medical College, Hospital and Research Centre, Dr D. Y. Patil Vidyapeeth, Pimpri, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ekta","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Orthodontics and Dentofacial Orthopeadics, Siddhpur Dental College and Hospital, Patan, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahavir Satishchand","family":"Bagrecha","sequence":"additional","affiliation":[{"name":"Department of Pulmonary Medicine, Dr D Y Patil Medical College, Hospital and Research Center, Pimpri, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rehan","family":"Saifuddin","sequence":"additional","affiliation":[{"name":"BDS, Lithuanian University of Health Sciences, Kaunas, Lithuania, Europe"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anish","family":"Nelson","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, AB Shetty Memorial Institute of Dental Sciences, Nitte (Deemed To Be University), Mangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mayank","family":"Sharma","sequence":"additional","affiliation":[{"name":"BDS, Central Coast Dental Care, Seaside, CA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,2,29]]},"reference":[{"key":"R1-20240829","doi-asserted-by":"crossref","first-page":"68","DOI":"10.4103\/ijrc.ijrc_35_19","article-title":"Efficacy of auto-PAP titration in obstructive sleep apnea: Single-center experience","volume":"9","author":"Unnithan","year":"2020","journal-title":"Indian J Respir Care"},{"key":"R2-20240829","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1183\/09031936.00027406","article-title":"Management Committee of EU COST ACTION B26. Sleep apnoea as an independent risk factor for cardiovascular disease: Current evidence, basic mechanisms and research priorities","volume":"29","author":"McNicholas","year":"2007","journal-title":"Eur Respir J"},{"key":"R3-20240829","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.resp.2011.03.015","article-title":"Obstructive sleep apnea and inflammation: Relationship to cardiovascular co-morbidity","volume":"178","author":"Kent","year":"2011","journal-title":"Respir Physiol Neurobiol"},{"key":"R4-20240829","doi-asserted-by":"crossref","first-page":"1852","DOI":"10.1164\/ajrccm.151.6.7767530","article-title":"Determinants of effective continuous positive airway pressure in obstructive sleep apnea. Role of respiratory effort","volume":"151","author":"Sforza","year":"1995","journal-title":"Am J Respir Crit Care Med"},{"key":"R5-20240829","first-page":"203","article-title":"Titration with automatic continuous positive airway pressure in obstructive sleep apnea","volume":"23","author":"Dias","year":"2017","journal-title":"Rev Port Pneumol (2006)"},{"key":"R6-20240829","doi-asserted-by":"crossref","first-page":"1217","DOI":"10.1164\/rccm.2109080","article-title":"Epidemiology of obstructive sleep apnea: A population health perspective","volume":"165","author":"Young","year":"2002","journal-title":"Am J Respir Crit Care Med"},{"key":"R7-20240829","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1164\/rccm.200302-265OC","article-title":"Prevalence of sleep-disordered breathing and sleep apnea in middle-aged urban Indian men","volume":"169","author":"Udwadia","year":"2004","journal-title":"Am J Respir Crit Care Med"},{"key":"R8-20240829","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1378\/chest.130.1.149","article-title":"Prevalence and risk factors of obstructive sleep apnea syndrome in a population of Delhi, India","volume":"130","author":"Sharma","year":"2006","journal-title":"Chest"},{"key":"R9-20240829","doi-asserted-by":"crossref","first-page":"2100","DOI":"10.1016\/S0140-6736(98)10532-9","article-title":"Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: A randomised prospective parallel trial","volume":"353","author":"Jenkinson","year":"1999","journal-title":"Lancet"},{"key":"R10-20240829","doi-asserted-by":"crossref","first-page":"1010","DOI":"10.1378\/chest.118.4.1010","article-title":"Constant vs. automatic continuous positive airway pressure therapy: Home evaluation","volume":"118","author":"d'Ortho","year":"2000","journal-title":"Chest"},{"key":"R11-20240829","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1136\/thx.53.8.643","article-title":"Evaluation of an auto-CPAP device for treatment of obstructive sleep apnoea","volume":"53","author":"Ficker","year":"1998","journal-title":"Thora\u00d7"},{"key":"R12-20240829","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1183\/09031936.98.12040764","article-title":"Detection of apnoeas, hypopnoeas and arousals by the AutoSet in the sleep apnoea\/hypopnoea syndrome","volume":"12","author":"Rees","year":"1998","journal-title":"Eur Respir J"}],"container-title":["Journal of Pharmacy and Bioallied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_501_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T18:21:58Z","timestamp":1787768518000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_501_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":12,"journal-issue":{"issue":"Suppl 1","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.4103\/jpbs.jpbs_501_23","relation":{},"ISSN":["0976-4879","0975-7406"],"issn-type":[{"value":"0976-4879","type":"print"},{"value":"0975-7406","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2]]},"assertion":[{"value":"2023-08-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-09-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}