{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:29:13Z","timestamp":1787761753140,"version":"build-2784847793"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"Suppl 2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>\n                    A\n                    <jats:sc>BSTRACT<\/jats:sc>\n                  <\/jats:title>\n                  <jats:p>The objective of this study is to compare retention capacity of mandibular implant-supported overdenture with all zirconia, zirconia\u2013PEEK, and all PEEK telescopic attachments. Sixty acrylic resin models of mandible were used. Telescopic attachment system was made up of all zirconia, all PEEK, and zirconia\u2013PEEK. Evaluation of retention force was done using universal testing machine. Obtained data were statistically evaluated. Highest initial force value was obtained with zirconia\u2013PEEK group. All PEEK and zirconia\u2013PEEK groups showed significantly decreased final retention values in comparison to their initial values. Zirconia can be regarded as the material of choice for telescopic crown, whereas polyetheretherketone and zirconia\u2013PEEK telescopic crowns showed retention loss over a period of time.<\/jats:p>","DOI":"10.4103\/jpbs.jpbs_54_23","type":"journal-article","created":{"date-parts":[[2023,5,5]],"date-time":"2023-05-05T16:00:32Z","timestamp":1683302432000},"page":"S910-S912","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["An In-vitro Evaluation of Retention Force of All PEEK, All Zirconia and Zirconia\u2013PEEK Telescopic Attachment for Mandibular Overdentures"],"prefix":"10.4103","volume":"15","author":[{"given":"Gujjalapudi","family":"Mahalakshmi","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Government Dental College and Hospital, Kadapa, Andra Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thandra Naga","family":"Sruthi","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Government Dental College and Hospital, Kadapa, Andra Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pradeep Kumar","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, Government Dental College, Dibrugarh, Assam, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muneendra","family":"Thandava","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Anil Neerukonda Institute of Dental Sciences, Vishakapatnam, Andra Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nirban","family":"Mitra","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Malla Reddy Institute of Dental Sciences, Hyderabad, Andra Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nirav G.","family":"Patel","sequence":"additional","affiliation":[{"name":"Reader, Department of Oral and Maxillofacial Surgery, Goenka Research Institute of Dental Science, Gandhinagar, Gujarat, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abhigyan","family":"Manas","sequence":"additional","affiliation":[{"name":"Reader, Department of Oral and Maxillofacial Surgery, Maharana Pratap Dental College, Saifai, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,4,28]]},"reference":[{"key":"R1-20240829","doi-asserted-by":"crossref","first-page":"375","DOI":"10.4317\/medoral.15.e375","article-title":"The implant supported milled bar overdenture:A literature review","volume":"15","author":"Bueno-Samper","year":"2010","journal-title":"Med Oral Patol Oral Cir Bucal"},{"key":"R2-20240829","first-page":"509","article-title":"Fabrication of zirconium primary copings to provide retention for a mandibular telescopic overdenture:A clinical report","volume":"21","author":"Uludag","year":"2008","journal-title":"Int J Prosthodont"},{"key":"R3-20240829","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1016\/j.jdent.2007.07.008","article-title":"An overview of zirconia ceramics:Basic properties and clinical applications","volume":"35","author":"Manicone","year":"2007","journal-title":"J Dent"},{"key":"R4-20240829","doi-asserted-by":"crossref","first-page":"614","DOI":"10.1016\/0022-3913(94)90294-1","article-title":"Stress analysis of different osseointegrated implants supporting distal extension prosthesis","volume":"72","author":"ElCharkawi","year":"1994","journal-title":"J Prosthet Dent"},{"key":"R5-20240829","first-page":"61","article-title":"Stress analysis of mandibular implant-retained overdenture with independent attachment system:Effect of restoration space and attachment height","volume":"63","author":"Ebadian","year":"2015","journal-title":"Gen Dent"},{"key":"R6-20240829","doi-asserted-by":"crossref","first-page":"200","DOI":"10.4172\/2332-0702.1000200","article-title":"The influence of palatal coverage on the retention force and fatigue resistance of mini dental implant maxillary overdenture","volume":"4","author":"El Mekawy","year":"2016","journal-title":"J Oral Hyg Health"},{"key":"R7-20240829","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1007\/s00784-009-0271-7","article-title":"Parameters affecting retentive force of electroformed doublecrown systems","volume":"14","author":"Beuer","year":"2010","journal-title":"Clin Oral Investig"},{"key":"R8-20240829","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1007\/s00784-012-0746-9","article-title":"Wear behavior of different doublecrown systems","volume":"17","author":"Engels","year":"2013","journal-title":"Clin Oral Investig"},{"key":"R9-20240829","doi-asserted-by":"crossref","first-page":"908","DOI":"10.3390\/ma9110908","article-title":"Suitability of secondary PEEK telescopic crown on zirconia primary crown:The influence of fabrication method and taper","volume":"9","author":"Merk","year":"2016","journal-title":"J Mater"},{"key":"R10-20240829","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.5958\/0976-5506.2019.02598.1","article-title":"Effect of using zirconia and metallic bar attachment overdentures on the supporting structures of mandibular edentulous ridge area (randomized control trial)","volume":"10","author":"Debis","year":"2019","journal-title":"Indian J Public Health Res Dev"},{"key":"R11-20240829","doi-asserted-by":"crossref","first-page":"2331","DOI":"10.1007\/s00784-018-2657-x","article-title":"Retentive force of PEEK secondary crowns on zirconia primary crowns over time","volume":"23","author":"Schubert","year":"2019","journal-title":"Clin Oral Investig"},{"key":"R12-20240829","first-page":"59","article-title":"Surface wear of all zicronia, all PEEK and zirconia-peek telescopic attachments for two implants retained mandibular complete overdentures. In -vitro study using scanning electron microscope","volume":"18","author":"Emera","year":"2019","journal-title":"IOSR J Dent Med Sci"},{"key":"R13-20240829","first-page":"725","article-title":"Resilient versus rigid telescopic attachment for two implants assisted complete mandibular overdentures:In vitro stress analysis study","volume":"60","author":"Hegazy","year":"2014","journal-title":"Egypt Dent J"}],"container-title":["Journal of Pharmacy and Bioallied Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_54_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:05:07Z","timestamp":1787760307000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jpbs.jpbs_54_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,28]]},"references-count":13,"journal-issue":{"issue":"Suppl 2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/jpbs.jpbs_54_23","relation":{},"ISSN":["0976-4879","0975-7406"],"issn-type":[{"value":"0976-4879","type":"print"},{"value":"0975-7406","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,28]]},"assertion":[{"value":"2023-01-21","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-25","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}