{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T13:38:07Z","timestamp":1793367487989,"version":"4.5.0"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T00:00:00Z","timestamp":1777852800000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["J West Afr Coll Surg"],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>The volume of the testis, mainly made up of seminiferous tubules, is a reflection of spermatogenesis. The accurate measurement of the testicular volume is therefore critical in the evaluation of testicular function. Aim is to compare the volumes obtained by Prader orchidometer, calliper and ultrasound with actual volume in humans.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      One hundred testicles from 50 men with advanced prostate cancer were recruited into the study over a 12-month period. Testicular volume was estimated\n                      <jats:italic toggle=\"yes\">in vivo<\/jats:italic>\n                      using Prader orchidometer, calliper, ultrasound scan and\n                      <jats:italic toggle=\"yes\">in vitro<\/jats:italic>\n                      after orchidectomy by water displacement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>\n                      Statistical analysis used paired\n                      <jats:italic toggle=\"yes\">t<\/jats:italic>\n                      test, Pearson correlation coefficient and simple linear regression analysis.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The age of the patients ranged from 55 to 82 years (mean 71.66 \u00b1 6.5). The mean testicular volumes were 16.13 \u00b1 4.5, 9.07 \u00b1 3.5 and 13.48 \u00b1 4.3mL for Prader orchidometer, calliper and ultrasound (Lambert formula), respectively. The mean volume from water displacement was 15.08 \u00b1 4.3\u2009mL. The Prader orchidometer most appropriately estimates the actual volume, (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.657). Calliper significantly underestimated the actual volume. Ultrasound estimation by Lambert formula showed no significant mean difference from the actual volume (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.362). In addition, the orchidometer and Lambert ultrasound formula showed excellent positive correlation with the actual volume (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.931,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001) and (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.869,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), respectively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Prader orchidometer provides an accurate and rapid assessment of testicular volume; it is, therefore, useful in clinical practice. Calliper does not give an accurate assessment of testicular volume. Of the three ultrasound formulae, Lambert formula is the best in providing a near accurate testicular volume measurement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/jwas.jwas_39_25","type":"journal-article","created":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T16:01:30Z","timestamp":1777910490000},"page":"438-444","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Testicular Volume Measurement: Comparison of Prader Orchidometer, Calliper and Ultrasound Estimates with Actual Volume Obtained by Water Displacement"],"prefix":"10.4103","volume":"16","author":[{"given":"Olufemi O.","family":"Ojewuyi","sequence":"first","affiliation":[{"name":"Department of Surgery, Osun State University, UNIOSUN Teaching Hospital, Osogbo, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuel A.","family":"Jeje","sequence":"additional","affiliation":[{"name":"Department of Surgery, University of Lagos, Lagos University Teaching Hospital, Idi-araba, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amogu Kalu","family":"Eziyi","sequence":"additional","affiliation":[{"name":"Department of Surgery, Osun State University, UNIOSUN Teaching Hospital, Osogbo, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abimbola A.","family":"Abolarinwa","sequence":"additional","affiliation":[{"name":"Department of Surgery, Lagos State University, Lagos State University Teaching Hospital, Ikeja, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abiodun Ronke","family":"Ojewuyi","sequence":"additional","affiliation":[{"name":"Department of Medical Microbiology and Parasitology, Osun State University, UNIOSUN Teaching Hospital, Osogbo, Nigeria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,5,4]]},"reference":[{"key":"CIT0001-20261030","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1159\/000474300","article-title":"Ultrasonic testicular texture and size in 444 men from the general population: Correlation to semen quality. Ultrasonic testicular texture and size in 444 men from the general population: Correlation to semen quality","volume":"24","author":"Lenz","year":"1993","journal-title":"Eur Urol"},{"key":"CIT0002-20261030","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1111\/j.0954-6820.1952.tb13395.x","article-title":"Clinical measurements of the testes in boys and men","volume":"266","author":"Hansen","year":"1952","journal-title":"Acta med Scand Suppl"},{"key":"CIT0003-20261030","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1136\/adc.37.195.514","article-title":"Measurement of testicular volume. Its application to assessment of maturation, and its use in diagnosis of hypogonadism","volume":"37","author":"Rundle","year":"1962","journal-title":"Arch Dis Child"},{"key":"CIT0004-20261030","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/S0022-5347(17)70767-7","article-title":"Normal growth and variation in the male genitalia from birth to maturity","volume":"48","author":"Schonfeld","year":"1942","journal-title":"J Urol"},{"key":"CIT0005-20261030","first-page":"240","article-title":"Testicular size: Assessment and clinical importance","volume":"7","author":"Prader","year":"1966","journal-title":"Triangle"},{"key":"CIT0006-20261030","first-page":"61","article-title":"Testicular volume during adolescence. Cross sectional and longitudinal studies","volume":"29","author":"Zachmann","year":"1974","journal-title":"Helv Paediatr Acta"},{"key":"CIT0007-20261030","doi-asserted-by":"crossref","first-page":"355","DOI":"10.3109\/01485017808988357","article-title":"New orchidometer","volume":"1","author":"Nahoum","year":"1978","journal-title":"Arch Androl"},{"key":"CIT0008-20261030","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1016\/S0015-0282(16)47126-8","article-title":"Significance of testicular size measurement in andrology. I. A new orchidometer and its clinical application","volume":"39","author":"Takihara","year":"1983","journal-title":"Fertil Steril"},{"key":"CIT0011-20261030","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1148\/radiol.2221001385","article-title":"Testicular volume: Comparison of orchidometer and US measurements in dogs","volume":"222","author":"Paltiel","year":"2002","journal-title":"Radiology"},{"key":"CIT0012-20261030","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/j.1745-7262.2006.00143.x","article-title":"Inter\/intrainvestigator variation in orchidometric measurements of testicular volume by ten investigators from five institutions","volume":"8","author":"Tatsunami","year":"2006","journal-title":"Asian J Androl"},{"key":"CIT0013-20261030","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.urology.2006.09.012","article-title":"Testicular volume measurement: comparison of ultrasonography, orchidometry, and water displacement","volume":"69","author":"Sakamoto","year":"2007","journal-title":"Urology"},{"key":"CIT0014-20261030","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1046\/j.1365-2605.2000.00240.x","article-title":"Inter-observer variation in the results of the clinical andrological examination including estimation of testicular size","volume":"23","author":"Carlsen","year":"2000","journal-title":"Int J Androl"},{"key":"CIT0015-20261030","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.anireprosci.2007.06.020","article-title":"Comparison between ultrasonographic and caliper measurements of testicular volume in the dog","volume":"108","author":"Gouletsou","year":"2008","journal-title":"Anim Reprod Sci"},{"key":"CIT0016-20261030","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1590\/S0102-865020160070000008","article-title":"Measurement of testicular volume in wistar rats using a caliper and ultrasonography in experimental surgery","volume":"31","author":"Bretas","year":"2016","journal-title":"Acta Cir Bras"},{"key":"CIT0017-20261030","first-page":"99","article-title":"Evaluation of measures taken by ultrasonography and caliper to estimate testicular volume and predict daily sperm output in the stallion","volume":"44","author":"Love","year":"1991","journal-title":"J Reprod Fertil Suppl"},{"key":"CIT0018-20261030","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/0020-7292(89)90476-1","article-title":"Testicular volume and seminal fluid profile in fertile and infertile males in Ilorin, Nigeria","volume":"28","author":"Sobowale","year":"1989","journal-title":"Int J Gynaecol Obstet"},{"key":"CIT0019-20261030","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1038\/aja.2008.48","article-title":"The reliability of ultrasonographic measurements for testicular volume assessment: Comparison of three common formulas with true testicular volume","volume":"11","author":"Hsieh","year":"2009","journal-title":"Asian J Androl"},{"key":"CIT0020-20261030","doi-asserted-by":"crossref","first-page":"348","DOI":"10.4103\/1119-3077.113460","article-title":"Accurracy of Prader orchidometer in measuring testicular volume","volume":"16","author":"Mbaeri","year":"2013","journal-title":"Nigerian J Clin Pract"},{"key":"CIT0021-20261030","first-page":"45","article-title":"Ultrasound measurement of testicular volume in healthy Nigerian adults","volume":"2","author":"Kelvin","year":"2012","journal-title":"J Asian Sci Res"},{"key":"CIT0022-20261030","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1111\/j.1464-410X.2003.04772.x","article-title":"Correlation of ultrasonographic and orchidometer measurements of testis volume in adults","volume":"93","author":"Schiff","year":"2004","journal-title":"BJU Int"},{"key":"CIT0023-20261030","first-page":"685","article-title":"Measurement of testicular volume in smaller testes: How accurate is the conventional orchidometer","volume":"30","author":"Chih-Chieh","year":"2013","journal-title":"J Androl"},{"key":"CIT0024-20261030","doi-asserted-by":"crossref","first-page":"S369","DOI":"10.1016\/j.fertnstert.2007.07.1228","article-title":"Ultrasonographically measured testicular volumes in 0 to 6 year old boys","volume":"88","author":"Kuijper","year":"2007","journal-title":"Fertil Steril"}],"container-title":["Journal of West African College of Surgeons"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/jwas.jwas_39_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T13:00:32Z","timestamp":1793365232000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/jwas.jwas_39_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,4]]},"references-count":22,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/jwas.jwas_39_25","relation":{},"ISSN":["2276-6944","2992-5827"],"issn-type":[{"value":"2276-6944","type":"print"},{"value":"2992-5827","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,4]]},"assertion":[{"value":"2025-02-25","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}