{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T17:10:40Z","timestamp":1788887440786,"version":"build-2803163510"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"133","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:p>\n                    <jats:bold>Objective:<\/jats:bold>\n                    To investigate the correlation between environmental noise in the intensive care unit (ICU) and the occurrence of delirium and heart rate variability (HRV) in patients after percutaneous coronary intervention (PCI), thereby providing a clinical basis for optimizing the ICU environment, reducing delirium incidence, and improving patient prognosis.\n                    <jats:bold>Methods:<\/jats:bold>\n                    We enrolled 132 patients admitted to the ICU after PCI between January 2023 and January 2024. Environmental noise was continuously monitored for 72\u2009h. We assessed delirium using the Nursing Delirium Screening Scale, and HRV parameters, including the standard deviation of normal-to-normal RR intervals (SDNN), the root mean square of successive differences between adjacent RR intervals (rMSSD), low-frequency power (LF), and high-frequency power (HF), were recorded via dynamic electrocardiography. We evaluated data using Pearson correlation analysis and logistic regression analysis.\n                    <jats:bold>Results:<\/jats:bold>\n                    The mean ICU noise level was 51.74\u2009\u00b1\u20094.82\u2009dB, and the incidence of delirium was 35.61%. Noise levels were significantly higher in the delirium group than in the non-delirium group (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt; 0.05). Pearson analysis revealed that noise levels were negatively correlated with SDNN, rMSSD, and HF (\n                    <jats:italic toggle=\"yes\">r<\/jats:italic>\n                    \u2009=\u2009\u22120.429 to \u22120.356,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt; 0.01), and positively correlated with LF (\n                    <jats:italic toggle=\"yes\">r<\/jats:italic>\n                    \u2009=\u20090.398,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    \u2009=\u20090.001). Multivariate logistic regression analysis identified ICU environmental noise [odds ratio (OR)\u2009=\u20091.171], age (OR\u2009=\u20091.060), and postoperative pain score (OR\u2009=\u20091.288) as independent risk factors for delirium (\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt; 0.05).\n                    <jats:bold>Conclusion:<\/jats:bold>\n                    Environmental noise levels in the ICU after PCI generally exceed recommendations. High noise levels are associated with abnormal HRV parameters and an increased risk of delirium. Optimizing the ICU acoustic environment may help reduce the incidence of delirium and improve patient outcomes.\n                  <\/jats:p>","DOI":"10.4103\/nah.nah_55_26","type":"journal-article","created":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T10:02:53Z","timestamp":1788343373000},"page":"914-922","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Correlation Analysis of Environmental Noise in the Intensive Care Unit with the Incidence of Delirium and Heart Rate Variability in Patients After Percutaneous Coronary Intervention"],"prefix":"10.4103","volume":"28","author":[{"given":"Mayire","family":"AJi","sequence":"first","affiliation":[{"name":"Department of Cardiology, The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xirenguli Zi","family":"Neng","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai Wu Ju Dan ALi","family":"Fu","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"YuHong","family":"Wu","sequence":"additional","affiliation":[{"name":"Department of Cardiology, The Sixth Affiliated Hospital of Xinjiang Medical University, Urumqi, Xinjiang 830002, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,31]]},"reference":[{"key":"R1-20260908","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.recesp.2023.11.015","article-title":"Coronary artery bypass, percutaneous coronary intervention, and mortality: a reflection on methods","volume":"77","author":"Elosua","year":"2024","journal-title":"Rev Esp Cardiol (Engl Ed)"},{"key":"R2-20260908","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.pcad.2024.12.005","article-title":"Complications of percutaneous coronary intervention","volume":"88","author":"Al-Ogaili","year":"2025","journal-title":"Prog Cardiovasc Dis"},{"key":"R3-20260908","doi-asserted-by":"crossref","first-page":"R187","DOI":"10.1186\/cc12870","article-title":"An investigation of sound levels on intensive care units with reference to the WHO guidelines","volume":"17","author":"Darbyshire","year":"2013","journal-title":"Crit Care"},{"key":"R4-20260908","doi-asserted-by":"crossref","first-page":"e70298","DOI":"10.1111\/nicc.70298","article-title":"Incidence and risk factors of delirium and subsyndromal delirium in intensive care unit patients: an observational study","volume":"31","author":"Dalli","year":"2026","journal-title":"Nurs Crit Care"},{"key":"R5-20260908","doi-asserted-by":"crossref","first-page":"2424","DOI":"10.1053\/j.jvca.2025.05.020","article-title":"Temporal trends and severity of postoperative delirium in cardiac surgery: insights from a systematic review and meta-analysis","volume":"39","author":"Shamsi","year":"2025","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R6-20260908","doi-asserted-by":"crossref","first-page":"e71485","DOI":"10.1002\/hsr2.71485","article-title":"The relationship between thirst and the incidence of delirium in patients admitted to intensive care units: a cross sectional study","volume":"8","author":"Barani","year":"2025","journal-title":"Health Sci Rep"},{"key":"R7-20260908","doi-asserted-by":"crossref","first-page":"e70056","DOI":"10.1111\/wvn.70056","article-title":"Impact of environmental noise on inpatient outcomes: a scoping review","volume":"22","author":"Sonoda","year":"2025","journal-title":"Worldviews Evid Based Nurs"},{"key":"R8-20260908","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1111\/nicc.12746","article-title":"Impact of sound levels on physiological and consciousness state of cardiovascular patients","volume":"27","author":"Morales-Can\u00e9","year":"2022","journal-title":"Nurs Crit Care"},{"key":"R9-20260908","doi-asserted-by":"crossref","first-page":"114861","DOI":"10.1016\/j.physbeh.2025.114861","article-title":"An exploratory study of the association between heart rate variability reactivity and prospective memory in a sample of coronary artery disease patients and healthy controls","volume":"294","author":"Hsu","year":"2025","journal-title":"Physiol Behav"},{"key":"R10-20260908","doi-asserted-by":"crossref","first-page":"3696825","DOI":"10.1155\/2019\/3696825","article-title":"Increased heart rate variability following elective percutaneous coronary intervention in patients with stable coronary artery disease and preprocedural anxiety","volume":"2019","author":"Oktaramdani","year":"2019","journal-title":"Cardiol Res Pract"},{"key":"R11-20260908","doi-asserted-by":"crossref","first-page":"e123","DOI":"10.1161\/CIR.0000000000000404","article-title":"2016 ACC\/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease","volume":"134","author":"Levine","year":"2016","journal-title":"Circulation"},{"key":"R12-20260908","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.jpainsymman.2004.07.009","article-title":"systematic, and continuous delirium assessment in hospitalized patients: the nursing delirium screening scale","volume":"29","author":"Gaudreau","year":"2005","journal-title":"J Pain Symptom Manage"},{"key":"R13-20260908","first-page":"CD010333","article-title":"Noise or sound management in the neonatal intensive care unit for preterm or very low birth weight infants","volume":"5","author":"Sibrecht","year":"2024","journal-title":"Cochrane Database Syst Rev"},{"key":"R14-20260908","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1111\/nicc.12934","article-title":"Relationship between noise levels and intensive care patients\u2019 clinical complexity: an observational simulation study","volume":"29","author":"Imbriaco","year":"2024","journal-title":"Nurs Crit Care"},{"key":"R15-20260908","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1186\/s13054-018-2182-y","article-title":"Noise in the intensive care unit and its influence on sleep quality: a multicenter observational study in Dutch intensive care units","volume":"22","author":"Simons","year":"2018","journal-title":"Crit Care"},{"key":"R16-20260908","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.aucc.2017.04.001","article-title":"Evaluation of a sound environment intervention in an ICU: a feasibility study","volume":"31","author":"Johansson","year":"2018","journal-title":"Aust Crit Care"},{"key":"R17-20260908","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1097\/NCQ.0b013e3181ed939a","article-title":"Nighttime noise issues that interrupt sleep after cardiac surgery","volume":"26","author":"Spence","year":"2011","journal-title":"J Nurs Care Qual"},{"key":"R18-20260908","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1007\/s10916-021-01752-5","article-title":"Delirium Variability is Influenced by the Sound Environment (DEVISE Study): how changes in the intensive care unit soundscape affect delirium incidence","volume":"45","author":"Sangari","year":"2021","journal-title":"J Med Syst"},{"key":"R19-20260908","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1177\/00033197241252467","article-title":"Relationship between coronary artery revascularization and postoperative delirium: progress and perspectives","volume":"77","author":"Lu","year":"2026","journal-title":"Angiology"},{"key":"R20-20260908","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1016\/j.envpol.2017.08.031","article-title":"Short-term association between personal exposure to noise and heart rate variability: the RECORD MultiSensor Study","volume":"231","author":"El Aarbaoui","year":"2017","journal-title":"Environ Pollut"},{"key":"R21-20260908","doi-asserted-by":"crossref","first-page":"6","DOI":"10.4103\/ed.ed_22_24","article-title":"A narrative review of environmental noise and cardiovascular health: from molecular mechanisms to public health impact","volume":"10","author":"Garg","year":"2025","journal-title":"Environ Dis"},{"key":"R22-20260908","doi-asserted-by":"crossref","first-page":"333","DOI":"10.4103\/nah.nah_77_25","article-title":"Effect of noise reduction on heart rate variability and stress response in patients with coronary artery disease after percutaneous coronary intervention","volume":"27","author":"Wang","year":"2025","journal-title":"Noise Health"},{"key":"R23-20260908","doi-asserted-by":"crossref","first-page":"783","DOI":"10.4103\/nah.nah_96_25","article-title":"Effects of binaural beat technology sound stimulation therapy on recovery in elderly patients with CHD post-PCI: a retrospective study","volume":"27","author":"Jiao","year":"2025","journal-title":"Noise Health"}],"container-title":["Noise and Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/nah.nah_55_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T17:04:17Z","timestamp":1788887057000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/nah.nah_55_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":23,"journal-issue":{"issue":"133","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/nah.nah_55_26","relation":{},"ISSN":["1463-1741","1998-4030"],"issn-type":[{"value":"1463-1741","type":"print"},{"value":"1998-4030","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2026-03-19","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-06-11","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}