{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T14:42:59Z","timestamp":1786718579382,"version":"build-2736575974"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Niger J Clin Pract"],"published-print":{"date-parts":[[2018]]},"DOI":"10.4103\/njcp.njcp_105_17","type":"journal-article","created":{"date-parts":[[2018,5,4]],"date-time":"2018-05-04T01:18:08Z","timestamp":1525396688000},"page":"546","source":"Crossref","is-referenced-by-count":33,"title":["Evaluation of the success and complication rates of self-drilling orthodontic mini-implants"],"prefix":"10.4103","volume":"21","author":[{"given":"J","family":"Szalma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Z","family":"Gurdan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"key-10.4103\/1119-3077.231882-1","unstructured":"Proffit WR, Fields HW, Sarver DM. Contemporary Orthodontics. 5th ed. St. Louis: Mosby; 2013. p. 295-9."},{"key":"key-10.4103\/1119-3077.231882-2","first-page":"554","volume-title":"Effects of pilot holes on longitudinal miniscrew stability and bony adaptation","author":"Carney","year":"2014","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/1119-3077.231882-3","first-page":"88","volume-title":"Effectiveness of en-masse retraction using midpalatal miniscrews and a modified transpalatal arch: Treatment duration and dentoskeletal changes","author":"Lee","year":"2014","journal-title":"Korean J Orthod"},{"key":"key-10.4103\/1119-3077.231882-4","first-page":"136","volume-title":"Management of open bite that developed during treatment for internal derangement and osteoarthritis of the temporomandibular joint","author":"Arai","year":"2015","journal-title":"Korean J Orthod"},{"key":"key-10.4103\/1119-3077.231882-5","first-page":"676","volume-title":"Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing class II division 2 patient","author":"Kim","year":"2006","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/1119-3077.231882-6","first-page":"19","volume-title":"Orthodontic screws to extrude impacted maxillary canines","author":"Kocsis","year":"2012","journal-title":"J Orofac Orthop"},{"key":"key-10.4103\/1119-3077.231882-7","first-page":"123","volume-title":"Orthodontic skeletal anchorage: Up-to-date review?","author":"Kyung","year":"2017","journal-title":"Orthod Waves"},{"key":"key-10.4103\/1119-3077.231882-8","first-page":"577","volume-title":"Failure rates and associated risk factors of orthodontic miniscrew implants: A meta-analysis","author":"Papageorgiou","year":"2012","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/1119-3077.231882-9","first-page":"388","volume-title":"Factors influencing the stability of miniscrews.A retrospective study on 300 miniscrews","author":"Manni","year":"2011","journal-title":"Eur J Orthod"},{"key":"key-10.4103\/1119-3077.231882-10","first-page":"121","volume-title":"How to calculate sample size for different study designs in medical research?","author":"Charan","year":"2013","journal-title":"Indian J Psychol Med","ISSN":"https:\/\/id.crossref.org\/issn\/0253-7176","issn-type":"print"},{"key":"key-10.4103\/1119-3077.231882-11","first-page":"23","volume-title":"Immediate loading of implants used for orthodontic anchorage","author":"Melsen","year":"2000","journal-title":"Clin Orthod Res"},{"key":"key-10.4103\/1119-3077.231882-12","first-page":"151","volume-title":"Clinical study on success rate of microscrew implants for orthodontic anchorage","author":"Park","year":"2003","journal-title":"Korean J Orthod"},{"key":"key-10.4103\/1119-3077.231882-13","first-page":"711","volume-title":"The efficient use of midpalatal miniscrew implants","author":"Lee","year":"2004","journal-title":"Angle Orthod"},{"key":"key-10.4103\/1119-3077.231882-14","first-page":"13","volume-title":"The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone","author":"Motoyoshi","year":"2009","journal-title":"Int J Oral Maxillofac Surg"},{"key":"key-10.4103\/1119-3077.231882-15","first-page":"1140","volume-title":"Correlating implant stability to bone structure","author":"Roz\u00e9","year":"2009","journal-title":"Clin Oral Implants Res"},{"key":"key-10.4103\/1119-3077.231882-16","first-page":"e6","volume-title":"The use of miniscrew implants for temporary skeletal anchorage in orthodontics: A comprehensive review","author":"Papadopoulos","year":"2007","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"key-10.4103\/1119-3077.231882-17","first-page":"9","volume-title":"Clinical use of miniscrew implants as orthodontic anchorage: Success rates and postoperative discomfort","author":"Kuroda","year":"2007","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/1119-3077.231882-18","first-page":"695","volume-title":"Application of orthodontic mini-implants in adolescents","author":"Motoyoshi","year":"2007","journal-title":"Int J Oral Maxillofac Surg"},{"key":"key-10.4103\/1119-3077.231882-19","first-page":"377","volume-title":", Roberts WE, Garetto LP, et al. The use of small titanium screws for orthodontic anchorage","author":"Deguchi","year":"2003","journal-title":"J Dent Res"},{"key":"key-10.4103\/1119-3077.231882-20","first-page":"95","volume-title":"Osseous adaptation to continuous loading of rigid endosseous implants","author":"Roberts","year":"1984","journal-title":"Am J Orthod"},{"key":"key-10.4103\/1119-3077.231882-21","first-page":"473","volume-title":"Load-related implant reaction of mini-implants used for orthodontic anchorage","author":"B\u00fcchter","year":"2005","journal-title":"Clin Oral Implants Res"},{"key":"key-10.4103\/1119-3077.231882-22","first-page":"47","volume-title":"Effect of pre-drilling on intraosseous temperature during self-drilling mini-implant placement in a porcine mandible model","author":"Gurd\u00e1n","year":"2017","journal-title":"J Oral Sci"},{"key":"key-10.4103\/1119-3077.231882-23","first-page":"417","volume-title":"A prospective multicenter clinical trial of 3i machined-surface implants: Results after 6 years of follow-up","author":"Weng","year":"2003","journal-title":"Int J Oral Maxillofac Implants"},{"key":"key-10.4103\/1119-3077.231882-24","first-page":"37","volume-title":"The effect of pre-cooling of the orthodontic miniscrew on the in vitro intraosseous heat production","author":"Gurd\u00e1n","year":"2017","journal-title":"Fogorv Sz"},{"key":"key-10.4103\/1119-3077.231882-25","first-page":"704","volume-title":"The application of mini-implants for orthodontic anchorage","author":"Tseng","year":"2006","journal-title":"Int J Oral Maxillofac Surg"},{"key":"key-10.4103\/1119-3077.231882-26","doi-asserted-by":"crossref","unstructured":"Deguchi T, Nasu M, Murakami K, Yabuuchi T, Kamioka H, Takano-Yamamoto T, et al. Quantitative evaluation of cortical bone thickness with computed tomographic scanning for orthodontic implants. Am J Orthod Dentofacial Orthop 2006;129:721.e7-12.","DOI":"10.1016\/j.ajodo.2006.02.026"},{"key":"key-10.4103\/1119-3077.231882-27","first-page":"673","volume-title":"Influence of different implant materials on the primary stability of orthodontic mini-implants","author":"Pan","year":"2012","journal-title":"Kaohsiung J Med Sci"},{"key":"key-10.4103\/1119-3077.231882-28","first-page":"697","volume-title":"Impact of bone quality, implant type, and implantation site preparation on insertion torques of mini-implants used for orthodontic anchorage","author":"Wilmes","year":"2011","journal-title":"Int J Oral Maxillofac Surg"},{"key":"key-10.4103\/1119-3077.231882-29","first-page":"669","volume-title":"Placement and removal torque values of orthodontic miniscrew implants","author":"Suzuki","year":"2011","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/1119-3077.231882-30","doi-asserted-by":"crossref","unstructured":"Meursinge Reynders RA, Ronchi L, Ladu L, van Etten-Jamaludin F, Bipat S. Insertion torque and success of orthodontic mini-implants: A systematic review. Am J Orthod Dentofacial Orthop 2012;142:596-614.e5.","DOI":"10.1016\/j.ajodo.2012.06.013"},{"key":"key-10.4103\/1119-3077.231882-31","first-page":"1445","volume-title":", Baratieri C, Ara\u00fajo MT, Souza MM, Maia LC.Root damage associated with intermaxillary screws: A systematic review","author":"Alves","year":"2012","journal-title":"Int J Oral Maxillofac Surg"},{"key":"key-10.4103\/1119-3077.231882-32","first-page":"e214","volume-title":"Root trauma and tooth loss through the application of pre-drilled transgingival fixation screws","author":"Schulte-Geers","year":"2012","journal-title":"J Craniomaxillofac Surg"},{"key":"key-10.4103\/1119-3077.231882-33","first-page":"1415","volume-title":"Five-year clinical, microbiological, and radiological outcome following treatment of peri-implantitis in man","author":"Leonhardt","year":"2003","journal-title":"J Periodontol"}],"container-title":["Nigerian Journal of Clinical Practice"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T13:36:55Z","timestamp":1786714615000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_105_17"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018]]},"references-count":33,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"alternative-id":["231882"],"URL":"https:\/\/doi.org\/10.4103\/njcp.njcp_105_17","relation":{},"ISSN":["1119-3077"],"issn-type":[{"value":"1119-3077","type":"print"}],"subject":[],"published":{"date-parts":[[2018]]}}}