{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T20:40:34Z","timestamp":1793824834161,"version":"4.6.1"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,2]]},"abstract":"<jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>To evaluate the effect of multiple-use and sterilization on cyclic fatigue and shaping ability of heat-treated nickel-titanium (NiTi) rotary instruments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A total of 120 acrylic blocks with S-shaped canals were photographed and prepared by HyFlex CM, ProTaper Next, and Twisted File. Ten new sets of each rotary instruments were used for four times. The autoclaving process was repeated after each use. Pre- and post instrumentation images were superimposed. The amount of resin removal and canal transportation by each system was measured in eleven different points. Instruments were subsequently subjected to a cyclic fatigue test in a double-curved artificial canal. The means and standard deviations of the number of cycles to failure (NCF) were calculated and statistically analyzed (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      No fractures occurred during the shaping of the simulated canals. The ProTaper Next removed the greatest amount of resin, whereas the Twisted File had the lowest values at all levels. Repeated clinical use and sterilization resulted in a decrease in the resin removal at most levels in Twisted File and ProTaper Next. In terms of canal transportation, an increase in a limited number of levels was detected after repeated use of all rotary files. Twisted File had the greatest cyclic fatigue resistance, followed by HyFlex CM and ProTaper Next (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The effects of repeated use and autoclaving on the cyclic fatigue resistance of HyFlex CM, ProTaper Next, and Twisted File were not significant. Canal transportation increased mostly in the apical region. The amount of resin removal decreased as the number of use increased for ProTaper Next and Twisted File instruments.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/njcp.njcp_166_20","type":"journal-article","created":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T02:55:50Z","timestamp":1692586550000},"page":"247-253","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Cyclic Fatigue Resistance and Shaping Ability of Heat-Treated Nickel-Titanium Instruments after Repeated Use"],"prefix":"10.4103","volume":"24","author":[{"given":"SG","family":"Kamali","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D","family":"Turkaydin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-16-20240907","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1097\/01.DON.0000129039.59003.9D","article-title":"Current challenges and concepts in the preparation of root canal systems: A review","volume":"30","author":"Peters","year":"2004","journal-title":"J Endod"},{"key":"R2-16-20240907","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1111\/j.1601-1546.2005.00152.x","article-title":"Mechanical preparation of root canals: Shaping goals, techniques and means","volume":"10","author":"H\u00fclsmann","year":"2005","journal-title":"Endod Topics"},{"key":"R3-16-20240907","doi-asserted-by":"crossref","first-page":"19","DOI":"10.4103\/1658-6816.124181","article-title":"Fractographic analysis of ProTaper and Mtwo systems: Breakage and distortion in severely curved roots of molars","volume":"1","author":"Basturk","year":"2014","journal-title":"Saudi J Oral Sci"},{"key":"R4-16-20240907","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/00004770-200003000-00008","article-title":"Defects in rotary nickel-titanium files after clinical use","volume":"26","author":"Sattapan","year":"2000","journal-title":"J Endod"},{"key":"R5-16-20240907","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1111\/j.1365-2591.2005.01020.x","article-title":"Defects in ProTaper S1 instruments after clinical use: Fractographic examination","volume":"38","author":"Cheung","year":"2005","journal-title":"Int Endod J"},{"key":"R6-16-20240907","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1111\/j.1365-2591.2005.00991.x","article-title":"Defects in ProTaper S1 instruments after clinical use: Longitudinal examination","volume":"38","author":"Peng","year":"2005","journal-title":"Int Endod J"},{"key":"R7-16-20240907","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1111\/j.1365-2591.2009.01651.x","article-title":"A metallurgical characterization of ten endodontic Ni-Ti instruments: Assessing the clinical relevance of shape memory and superelastic properties of Ni-Ti endodontic instruments","volume":"43","author":"Zinelis","year":"2010","journal-title":"Int Endod J"},{"key":"R8-16-20240907","doi-asserted-by":"crossref","first-page":"1293","DOI":"10.1016\/j.joen.2011.05.023","article-title":"Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel","volume":"37","author":"Testarelli","year":"2011","journal-title":"J Endod"},{"key":"R9-16-20240907","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1111\/iej.12924","article-title":"New thermomechanically treated NiTi alloys \u2013 A review","volume":"51","author":"Zupanc","year":"2018","journal-title":"Int Endod J"},{"key":"R12-16-20240907","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1016\/j.joen.2009.05.027","article-title":"Usage parameters of nickel-titanium rotary instruments: A survey of endodontists in the United States","volume":"35","author":"Bird","year":"2009","journal-title":"J Endod"},{"key":"R13-16-20240907","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1016\/j.joen.2013.10.016","article-title":"Evaluation of a new filing system's ability to maintain canal morphology","volume":"40","author":"Thompson","year":"2014","journal-title":"J Endod"},{"key":"R14-16-20240907","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1016\/j.joen.2019.10.024","article-title":"Cyclic fatigue resistance of multiused reciproc blue \u0131nstruments during retreatment procedure","volume":"46","author":"Serefoglu","year":"2020","journal-title":"J Endod"},{"key":"R15-16-20240907","doi-asserted-by":"crossref","first-page":"301","DOI":"10.5395\/rde.2017.42.4.301","article-title":"The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments","volume":"42","author":"\u00d6zy\u00fcrek","year":"2017","journal-title":"Restor Dent Endod"},{"key":"R16-16-20240907","doi-asserted-by":"crossref","first-page":"1686","DOI":"10.1016\/j.joen.2015.06.012","article-title":"Cyclic fatigue of ProFile Vortex and Vortex Blue nickel-titanium files in single and double curvatures","volume":"41","author":"Duke","year":"2015","journal-title":"J Endod"},{"key":"R17-16-20240907","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1046\/j.0143-2885.2001.00494.x","article-title":"Dynamic torque and apical forces of ProFile. 04 rotary instruments during preparation of curved canals","volume":"35","author":"Peters","year":"2002","journal-title":"Int Endod J"},{"key":"R18-16-20240907","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1046\/j.1365-2591.1999.00201.x","article-title":"Cyclic fatigue of Profile rotary instruments after simulated clinical use","volume":"32","author":"Yared","year":"1999","journal-title":"Int Endod J"},{"key":"R19-16-20240907","doi-asserted-by":"crossref","first-page":"802","DOI":"10.1111\/j.1365-2591.2012.02036.x","article-title":"Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion","volume":"45","author":"Gambarini","year":"2012","journal-title":"Int Endod J"},{"key":"R20-16-20240907","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.tripleo.2004.10.013","article-title":"Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals","volume":"100","author":"Bahia","year":"2005","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"key":"R21-16-20240907","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1016\/j.joen.2015.01.011","article-title":"Effect of repeated simulated clinical use and sterilization on the cutting efficiency and flexibility of Hyflex CM nickel-titanium rotary files","volume":"41","author":"Seago","year":"2015","journal-title":"J Endod"},{"key":"R22-16-20240907","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1111\/iej.12550","article-title":"Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel\u2013Titanium instruments","volume":"49","author":"Zhao","year":"2016","journal-title":"Int Endod J"},{"key":"R23-16-20240907","first-page":"108","article-title":"An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography","volume":"5","author":"Kumar","year":"2013","journal-title":"J Int Oral Health"},{"key":"R25-16-20240907","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.joen.2017.11.014","article-title":"Effect of dynamic \u0131mmersion in sodium hypochlorite and EDTA solutions on cyclic fatigue resistance of waveone and waveone gold reciprocating nickel-titanium files","volume":"44","author":"Uslu","year":"2018","journal-title":"J Endod"},{"key":"R26-16-20240907","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/s10266-018-0388-8","article-title":"Effects of etidronate, NaOCl, EDTA irrigation solutions and their combinations on cyclic fatigue resistance of nickel\u2013titanium single-file rotary and reciprocating instruments at body temperature","volume":"107","author":"Erik","year":"2019","journal-title":"Odontology"},{"key":"R27-16-20240907","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/j.joen.2006.10.012","article-title":"Modes of failure of ProTaper nickel\u2013titanium rotary instruments after clinical use","volume":"33","author":"Wei","year":"2007","journal-title":"J Endod"},{"key":"R28-16-20240907","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.jds.2016.04.006","article-title":"Various heat-treated nickel\u2013titanium rotary instruments evaluated in S-shaped simulated resin canals","volume":"12","author":"Gu","year":"2017","journal-title":"J Dent Sci"},{"key":"R29-16-20240907","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1111\/etp.12043","article-title":"Critical evaluation of root canal transportation by instrumentation","volume":"29","author":"B\u00fcrklein","year":"2013","journal-title":"Endod Topics"},{"key":"R30-16-20240907","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1016\/j.joen.2016.03.010","article-title":"In vitro comparison of cyclic fatigue resistance of ProTaper Next, HyFlex CM, OneShape, and ProTaper Universal instruments in a canal with a double curvature","volume":"42","author":"Top\u00e7uo\u011flu","year":"2016","journal-title":"J Endod"},{"key":"R31-16-20240907","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1007\/s10266-018-0401-2","article-title":"Cyclic fatigue resistance of three rotary file systems in a dynamic model after immersion in sodium hypochlorite","volume":"107","author":"Palma","year":"2019","journal-title":"Odontology"},{"key":"R32-16-20240907","doi-asserted-by":"crossref","first-page":"2042","DOI":"10.1002\/jemt.23374","article-title":"Cyclic fatigue and energy-dispersive X-ray spectroscopy examination of the novel ROTATE instrument","volume":"82","author":"Ertu\u011frul","year":"2019","journal-title":"Microsc Res Tech"},{"key":"R33-16-20240907","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1016\/j.joen.2016.01.025","article-title":"Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature","volume":"42","author":"de Vasconcelos","year":"2016","journal-title":"J Endod"},{"key":"R34-16-20240907","doi-asserted-by":"crossref","first-page":"41","DOI":"10.4103\/njcp.njcp_343_19","article-title":"Comparison of the cyclic fatigue resistance of hyflex EDM, vortex blue, protaper gold, and onecurve nickel\u2013Titanium instruments","volume":"23","author":"Uygun","year":"2020","journal-title":"Niger J Clin Pract"}],"container-title":["Nigerian Journal of Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_166_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:14:42Z","timestamp":1787166882000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_166_20"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/njcp.njcp_166_20","relation":{},"ISSN":["1119-3077"],"issn-type":[{"value":"1119-3077","type":"print"}],"subject":[],"published":{"date-parts":[[2021,2]]}}}