{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:58:25Z","timestamp":1787169505521,"version":"build-2736575974"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Backgrounds:<\/jats:title>\n                    <jats:p>Traditionally, vascular interventions have been performed through the femoral artery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate risk factors affecting access-site complications in patients with hepatocellular carcinoma or peripheral arterial disease in lower extremity who underwent vascular intervention by accessing the common femoral artery (CFA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Patients and Methods:<\/jats:title>\n                    <jats:p>From December 2015 to November 2018, 287 patients underwent transarterial chemoembolization (TACE) or peripheral vascular intervention with ultrasound (US)-guided CFA access. Standard 18-gauge (G) access was used in 127 patients and Micropuncture\u00ae 21-G needles in 160 patients. Most access sites were managed with vascular closure devices and several were managed with manual compression. Within 24 hours after the procedure, all patients underwent US to evaluate the puncture site.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Access-site complications occurred in 55 of 287 patients: 34 hematomas (11.9%), 20 pseudoaneurysms (7.0%), and 1 dissection (0.4%). In the crude model, risk factors related to access-site complications were the usage of 18-G needles (OR, 2.18; 95% CI, 1.17-4.07;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.014), smoking (OR, 2.23; 95% CI, 1.16-4.27;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.016), and approach route (OR, 3.23; 95% CI, 1.33-7.82;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.009). Needle size (OR, 2.13; 95% CI, 1.10-4.12;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.025) was the only factor associated with access-site complications in the adjusted model.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Needle profile was the only factor associated with access-site complications in this study. Therefore, a needle with a smaller profile than an 18-G needle will reduce the incidence of complications at the access site.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/njcp.njcp_37_21","type":"journal-article","created":{"date-parts":[[2022,1,19]],"date-time":"2022-01-19T07:38:30Z","timestamp":1642577910000},"page":"85-89","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Risk Factors Affecting Complications of Access Site in Vascular Intervention through Common Femoral Artery"],"prefix":"10.4103","volume":"25","author":[{"given":"MO","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KU","family":"Jeong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"KM","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"YG","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-14-20240907","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1002\/ccd.24335","article-title":"Pitfalls associated with the use of current recommendations for fluoroscopy-guided common femoral artery access","volume":"81","author":"Yaganti","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"R2-14-20240907","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1159\/000362536","article-title":"Femoral micropuncture or routine introducer study (FEMORIS)","volume":"129","author":"Ambrose","year":"2014","journal-title":"Cardiology"},{"key":"R3-14-20240907","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1002\/ccd.23330","article-title":"A novel, minimally invasive access technique versus standard 18-gauge needle set for femoral access","volume":"79","author":"Ben-Dor","year":"2012","journal-title":"Catheter Cardiovasc Interv"},{"key":"R4-14-20240907","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1007\/s00270-013-0669-0","article-title":"Comparison of a 21G micropuncture needle and a regular 19G access needle for antegrade arterial access into the superficial femoral artery","volume":"37","author":"Gutzeit","year":"2014","journal-title":"Cardiovasc Intervent Radiol"},{"key":"R5-14-20240907","first-page":"157","article-title":"Fluroscopically-guided micropuncture femoral artery access for large-caliber sheath insertion","volume":"23","author":"Cilingiroglu","year":"2011","journal-title":"J Invasive Cardiol"},{"key":"R6-14-20240907","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1053\/j.jvca.2012.07.007","article-title":"Ultrasound-guided vascular access: A comprehensive review","volume":"27","author":"Weiner","year":"2013","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R7-14-20240907","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.jcin.2010.10.011","article-title":"Incidence, prognostic impact, and influence of antithrombotic therapy on access and nonaccess site bleeding in percutaneous coronary intervention","volume":"4","author":"Verheugt","year":"2011","journal-title":"JACC Cardiovasc Interv"},{"key":"R8-14-20240907","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.jcin.2010.04.015","article-title":"Real-time ultrasound guidance facilitates femoral arterial access and reduces vascular complications: FAUST (Femoral Arterial Access With Ultrasound Trial)","volume":"3","author":"Seto","year":"2010","journal-title":"JACC Cardiovasc Interv"},{"key":"R9-14-20240907","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/0002-9149(92)90677-Q","article-title":"Peripheral vascular complications after conventional and complex percutaneous coronary interventional procedures","volume":"69","author":"Muller","year":"1992","journal-title":"Am J Cardiol"},{"key":"R10-14-20240907","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1053\/pcad.2003.YPCAD13","article-title":"Smoking and endothelial function","volume":"45","author":"Puranik","year":"2003","journal-title":"Prog Cardiovasc Dis"},{"key":"R11-14-20240907","first-page":"1200","article-title":"Vascular complications associated with arteriotomy closure devices in patients undergoing percutaneous coronary procedures: A meta-analysis","volume":"44","author":"Nikolsky","year":"2004","journal-title":"J Am Coll Cardiol"}],"container-title":["Nigerian Journal of Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_37_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:07:08Z","timestamp":1787166428000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_37_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/njcp.njcp_37_21","relation":{},"ISSN":["1119-3077"],"issn-type":[{"value":"1119-3077","type":"print"}],"subject":[],"published":{"date-parts":[[2022,1]]}}}