{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T13:32:09Z","timestamp":1787923929985,"version":"build-2784847793"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,8]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Preeclampsia may be complicated by cerebral edema and elevated intracranial pressure (ICP), yet magnetic resonance imaging is not always feasible for urgent or serial assessment. Ultrasonographic optic nerve sheath diameter (ONSD) measurement is a bedside surrogate that may reflect ICP-related changes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>To compare ONSD values among nonpregnant healthy women, normotensive pregnant women, and women with preeclampsia (with and without severe features), and to evaluate the discriminative performance of ONSD for hypertensive disorders of pregnancy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      This single-center retrospective cohort study (January 2021\u2013January 2025) included 79 participants: nonpregnant healthy women (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 19), normotensive pregnant women (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 20), preeclampsia (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 20), and severe preeclampsia (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 20). Preeclampsia diagnosis\/severity followed the American College of Obstetricians and Gynecologists criteria. ONSD was measured by ocular ultrasonography (Voluson S8) 3 mm posterior to the globe in both eyes; the mean of both eyes was analyzed. Measurements were performed contemporaneously by four radiologists and recorded by consensus.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Groups were comparable regarding age, gravidity, parity, and gestational week at measurement (mean gestational age 34.20 \u00b1 0.70 weeks;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; 0.05). Mean ONSD increased stepwise across groups: 4.11 \u00b1 0.21 mm (nonpregnant controls), 4.62 \u00b1 0.19 mm (pregnant controls), 5.71 \u00b1 0.18 mm (preeclampsia), and 5.99 \u00b1 0.20 mm (severe preeclampsia) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). An ONSD cutoff of 5.15 mm distinguished preeclampsia\/severe preeclampsia from the control groups with excellent diagnostic performance (AUC = 1.000;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>ONSD is higher in preeclampsia, especially in severe cases. Ocular ultrasound may help with quick screening and follow-up, but confirmation in larger studies using imaging or invasive ICP standards is needed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/njcp.njcp_572_25","type":"journal-article","created":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T05:00:10Z","timestamp":1787720410000},"page":"890-896","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Optic Nerve Sheath Diameter as a Marker of Elevated Intracranial Pressure in Preeclampsia Compared to Controls"],"prefix":"10.4103","volume":"29","author":[{"given":"S","family":"\u015eim\u015fek","sequence":"first","affiliation":[{"name":"Department of Radiology, Gazi Ya\u015fargil Training and Research Hospital, Diyarbak\u0131r, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u0130","family":"Ba\u015fk\u0131r","sequence":"additional","affiliation":[{"name":"Department of Obstetrics and Gynecology, Ac\u0131badem Eski\u015fehir Hospital, Eski\u015fehir, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T","family":"Sa\u011flam","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gazi Ya\u015fargil Training and Research Hospital, Diyarbak\u0131r, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A","family":"O\u011fuz","sequence":"additional","affiliation":[{"name":"Department of Radiology, Gazi Ya\u015fargil Training and Research Hospital, Diyarbak\u0131r, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B","family":"\u00c7abuk","sequence":"additional","affiliation":[{"name":"Department of Radiology, Ac\u0131badem Eski\u015fehir Hospital, Eski\u015fehir, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,26]]},"reference":[{"key":"R1-20260828","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1055\/s-0037-1604471","article-title":"Preeclampsia","volume":"39","author":"Ramos","year":"2017","journal-title":"Rev Bras Ginecol Obstet"},{"key":"R2-20260828","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1067\/S0002-9378(03)00651-3","article-title":"Diffusion imaging may predict reversible brain lesions in eclampsia and severe preeclampsia: \u0130nitial experience","volume":"189","author":"Loureiro","year":"2003","journal-title":"Am J Obstet Gynecol"},{"key":"R3-20260828","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1080\/10641955.2020.1849275","article-title":"Correlation between cerebral biomarkers and optic nerve sheath diameter in patients with severe preeclampsia","volume":"40","author":"Brzan","year":"2021","journal-title":"Hypertens Pregnancy"},{"key":"R4-20260828","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/j.ijoa.2018.06.005","article-title":"Ocular ultrasonography for diagnosing increased intracranial pressure in patients with severe preeclampsia","volume":"36","author":"Brzan","year":"2018","journal-title":"Int J Obstet Anesth"},{"key":"R5-20260828","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.1097\/ALN.0b013e318246ea1a","article-title":"Optic nerve sheath diameter used as ultrasonographic assessment of the incidence of raised intracranial pressure in preeclampsia: A pilot study","volume":"116","author":"Dubost","year":"2012","journal-title":"Anesthesiology"},{"key":"R6-20260828","doi-asserted-by":"crossref","first-page":"5","DOI":"10.4274\/jtgga.galenos.2022.2022-3-3","article-title":"Optic nerve sheath diameter measurements using ultrasonography to diagnose raised intracranial pressure in preeclampsia: An observational study","volume":"24","author":"Biswas","year":"2023","journal-title":"J Turk Ger Gynecol Assoc"},{"key":"R7-20260828","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1213\/ANE.0000000000003759","article-title":"Point-of-care ultrasound abnormalities in late-onset severe preeclampsia: Prevalence and association with serum albumin and brain natriuretic peptide","volume":"128","author":"Ortner","year":"2019","journal-title":"Anesth Analg"},{"key":"R8-20260828","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.preghy.2019.11.011","article-title":"Evaluation of the clinical impact of the revised ISSHP and ACOG definitions on preeclampsia","volume":"19","author":"Bouter","year":"2020","journal-title":"Pregnancy Hypertens"},{"key":"R9-20260828","doi-asserted-by":"crossref","first-page":"366","DOI":"10.4103\/aer.aer_117_22","article-title":"Ultrasonographic changes in transorbital measurement of optic nerve sheath diameter in magnesium sulfate-treated severely preeclamptic patients: A prospective observational study","volume":"16","author":"Rani","year":"2022","journal-title":"Anesth Essays Res"},{"key":"R10-20260828","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1007\/BF01383384","article-title":"Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension II. Patient study","volume":"26","author":"Helmke","year":"1996","journal-title":"Pediatr Radiol"},{"key":"R11-20260828","doi-asserted-by":"crossref","first-page":"896","DOI":"10.7326\/M19-0812","article-title":"Bedside optic nerve ultrasonography for diagnosing increased intracranial pressure: A systematic review and meta-analysis","volume":"171","author":"Koziarz","year":"2019","journal-title":"Ann Intern Med"},{"key":"R12-20260828","doi-asserted-by":"crossref","first-page":"JC46","DOI":"10.7326\/ACPJ202004210-046","article-title":"Optic nerve ultrasonography has 94% sensitivity and 87% specificity for diagnosing increased intracranial pressure","volume":"172","author":"Messenger","year":"2020","journal-title":"Ann Intern Med"},{"key":"R13-20260828","doi-asserted-by":"crossref","first-page":"2187253","DOI":"10.1080\/14767058.2023.2187253","article-title":"Usefulness of optic nerve sheath diameter measurement in hypertensive patients during pregnancy and the puerperium","volume":"36","author":"Berty","year":"2023","journal-title":"J Matern Fetal Neonatal Med"},{"key":"R14-20260828","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1186\/s12884-024-06858-5","article-title":"The optic nerve sheath in hypertensive disorders of pregnancy and perinatal outcomes: A cohort study","volume":"24","author":"da Mota","year":"2024","journal-title":"BMC Pregnancy Childbirth"},{"key":"R15-20260828","doi-asserted-by":"crossref","first-page":"E237","DOI":"10.1097\/AOG.0000000000003891","article-title":"Gestational hypertension and preeclampsia: ACOG practice bulletin, number 222","volume":"135","year":"2020","journal-title":"Obstet Gynecol"},{"key":"R16-20260828","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/s40477-014-0144-z","article-title":"Intra- and interobserver reliability of transorbital sonographic assessment of the optic nerve sheath diameter and optic nerve diameter in healthy adults","volume":"19","author":"Lochner","year":"2014","journal-title":"J Ultrasound"},{"key":"R17-20260828","doi-asserted-by":"crossref","first-page":"42","DOI":"10.4103\/aer.AER_218_17","article-title":"Ultrasonographic optic nerve sheath diameter as a surrogate measure of raised intracranial pressure in severe pregnancy-induced hypertension patients","volume":"12","author":"Singh","year":"2018","journal-title":"Anesth Essays Res"},{"key":"R18-20260828","doi-asserted-by":"crossref","first-page":"865","DOI":"10.1007\/s13760-023-02454-0","article-title":"Monitoring of optic sheath diameter during acute migraine attack: An objective criteria for the severity of disease","volume":"124","author":"\u015eim\u015fek","year":"2024","journal-title":"Acta Neurol Belg"},{"key":"R19-20260828","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1080\/11101849.2020.1816153","article-title":"Optic nerve sheath diameter versus extra-vascular lung water detected by ultrasound in volume status prediction in severe preeclampsia","volume":"36","author":"Mowafy","year":"2020","journal-title":"Egypt J Anaesth"},{"key":"R20-20260828","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1177\/0284185118776501","article-title":"Ultrasonographic optic nerve sheath diameter to detect increased intracranial pressure in adults: A meta-analysis","volume":"60","author":"Kim","year":"2019","journal-title":"Acta Radiol"},{"key":"R21-20260828","doi-asserted-by":"crossref","first-page":"2062","DOI":"10.1007\/s00134-008-1149-x","article-title":"Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients","volume":"34","author":"Geeraerts","year":"2008","journal-title":"Intensive Care Med"},{"key":"R22-20260828","doi-asserted-by":"crossref","first-page":"1896","DOI":"10.18203\/2320-1770.ijrcog20221664","article-title":"Comparison of optic nerve sheath diameter in preeclampsia and normal pregnancy using ocular USG","volume":"11","author":"Jan","year":"2022","journal-title":"Int J Reprod Contracept Obstet Gynecol"},{"key":"R23-20260828","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1002\/jcu.22735","article-title":"Optic nerve sonography and ophthalmic artery Doppler velocimetry in healthy pregnant women: An Australian cohort study","volume":"47","author":"Kane","year":"2019","journal-title":"J Clin Ultrasound"},{"key":"R24-20260828","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.jcrc.2015.10.009","article-title":"Ultrasound assessment of optic nerve sheath diameter in healthy volunteers","volume":"31","author":"Goeres","year":"2016","journal-title":"J Crit Care"},{"key":"R25-20260828","doi-asserted-by":"crossref","first-page":"764","DOI":"10.3389\/fneur.2020.00764","article-title":"Effects of age and sex on optic nerve sheath diameter in healthy volunteers and patients with traumatic brain injury","volume":"11","author":"Cardim","year":"2020","journal-title":"Front Neurol"}],"container-title":["Nigerian Journal of Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_572_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T13:00:11Z","timestamp":1787922011000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_572_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":25,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/njcp.njcp_572_25","relation":{},"ISSN":["1119-3077","2229-7731"],"issn-type":[{"value":"1119-3077","type":"print"},{"value":"2229-7731","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"2025-08-23","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-07-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}