{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T02:00:36Z","timestamp":1787623236831,"version":"build-2736575974"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Hybrid-abutment crowns and screwmentable crowns offer a fusion of the benefits from both screw and cement-retained restorations, potentially enhancing the overall performance of the restoration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aim:<\/jats:title>\n                    <jats:p>This study aimed to evaluate the screw loosening and fracture strength of hybrid-abutment crowns and screwmentable crowns made with two different materials.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      Forty single-crown were made on titanium implants and divided into four groups (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 10) [SM-Ti: Screwmentable titanium-porcelain crowns on stock titanium abutment; SM-Zr: Screwmentable zirconia-porcelain crowns on stock zirconia abutment; AC-Ti: Titanium-porcelain abutment crowns; AC-Zr: Zirconia-porcelain abutment crowns.] Specimens were torqued with 30 NCm and thermocycled between 5\u2103 and 55\u2103 in 20-second cycles for 5000 cycles. Removal torque values (RTV) were measured. Following the RTV measurement, the screws were changed with fresh screws and torqued again. Afterwards, specimens were loaded to fracture and fracture strengths were recorded, failure modes were examined.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis Used:<\/jats:title>\n                    <jats:p>Analysis of variance and Bonferroni test was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The AC-Ti group displayed the highest mean torque loss (%20.09 \u00b1 6.49) and the SM-Ti group displayed the lowest (%9.59 \u00b1 8.84). Only the difference between AC-Ti and SM-Ti groups was found statistically significant, there are no significant differences between other groups. The fracture strengths are 385.84 \u00b1 27.68 N, 313.18 \u00b1 39.97 N, 272.69 \u00b1 35.03 N, and 156.71 \u00b1 19.83 N for AC-Ti, AC-Zr, SM-Ti, and SM-Zr groups, respectively and all differences were found to be statistically significant. Failures occurred as deformation in titanium components, whereas fractures were observed in zirconia components.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Screw loosening was observed only in the AC-Ti group. No significant difference was observed among the torque loss values in the remaining groups. Titanium and zirconia materials do not exert any influence on screw loosening after thermal aging for hybrid-abutment crowns. Moreover, when assessing fracture strength, hybrid-abutment crowns exhibit superior strength and durability compared to screwmentable crowns.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/njcp.njcp_772_23","type":"journal-article","created":{"date-parts":[[2025,4,27]],"date-time":"2025-04-27T23:00:09Z","timestamp":1745794809000},"page":"461-470","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["In-Vitro Comparison of Screw Loosening, Fracture Strength and Failure Mode of Implant-Supported Hybrid-Abutment Crowns and Screwmentable Crowns Manufactured with Different Materials"],"prefix":"10.4103","volume":"28","author":[{"given":"\u0130","family":"\u00c7\u00f6tert","sequence":"first","affiliation":[{"name":"Private Practice, \u0130zmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M","family":"Ulusoy","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Bornova, Ege University, \u0130zmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"AG","family":"T\u00fcrk","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics Bornova, Ege University, \u0130zmir, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,26]]},"reference":[{"key":"R1-20260423","first-page":"S59","article-title":"Single implant and crown versus fixed partial denture: A cost-benefit, patient-centred analysis","volume":"9","author":"Goodacre","year":"2016","journal-title":"Eur J Oral Implantol"},{"key":"R2-20260423","first-page":"14","article-title":"Guidelines for implant abutment selection for partially edentulous patients","volume":"31","author":"Drago","year":"2010","journal-title":"Compend Contin Educ Dent"},{"key":"R4-20260423","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1600-0501.2009.01787.x","article-title":"A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions","volume":"20","author":"Sailer","year":"2009","journal-title":"Clin Oral Impl Res"},{"key":"R5-20260423","first-page":"46","article-title":"Biomedical applications of titanium and its alloys","volume":"60","author":"Elias","year":"2008","journal-title":"Biol Mater Sci"},{"key":"R6-20260423","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1111\/jerd.12031","article-title":"Clinical outcomes of implant abutments in the anterior region: A systematic review","volume":"25","author":"Bidra","year":"2013","journal-title":"J Esthet Restor Dent"},{"key":"R7-20260423","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1111\/j.1600-0501.2009.01785.x","article-title":"Are ceramic implants a viable alternative to titanium implants? A systematic literature review","volume":"20","author":"Andreiotelli","year":"2009","journal-title":"Clin Oral Implants Res"},{"key":"R8-20260423","first-page":"139","article-title":"Performance of CAD\/CAM monolithic ceramic implant-supported restorations bonded to titanium inserts: A systematic review","volume":"10","author":"Conejo","year":"2017","journal-title":"Eur J Oral Implantol"},{"key":"R9-20260423","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1186\/s40729-020-00220-y","article-title":"Hybrid-abutment-restoration: Effect of material type on torque maintenance and fracture resistance after thermal aging","volume":"6","author":"Al-Zordk","year":"2020","journal-title":"Int J Implant Dent"},{"key":"R10-20260423","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1111\/jopr.12278","article-title":"Fracture strength of implant-supported ceramic crowns with customized zirconia abutments: Screw retained vs. cement retained","volume":"25","author":"Nogueira","year":"2016","journal-title":"J Prosthodont"},{"key":"R11-20260423","first-page":"46","article-title":"Considerations for fabrication of CAD-CAM abutments: Part 1. Selection of titanium block and fabrication process","volume":"23","author":"Ko","year":"2019","journal-title":"Implantol"},{"key":"R12-20260423","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1016\/j.joms.2005.05.158","article-title":"Virtual-designed and computer-milled implant abutments","volume":"63","author":"Priest","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"R13-20260423","doi-asserted-by":"crossref","first-page":"522","DOI":"10.11607\/ijp.4307","article-title":"Prefabricated versus customized abutments: A retrospective analysis of loosening of cement-retained fixed implant-supported reconstructions","volume":"28","author":"Korsch","year":"2015","journal-title":"Int J Prosthodont"},{"key":"R14-20260423","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1111\/clr.13395","article-title":"Mechanical behavior of posterior all-ceramic hybrid-abutment-crowns versus hybrid-abutments with separate crowns-A laboratory study","volume":"30","author":"Nouh","year":"2019","journal-title":"Clin Oral Implants Res"},{"key":"R15-20260423","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1111\/prd.12168","article-title":"Screw retained vs. cement retained implant-supported fixed dental prosthesis","volume":"73","author":"Wittneben","year":"2017","journal-title":"Periodontol 2000"},{"key":"R16-20260423","doi-asserted-by":"crossref","first-page":"127","DOI":"10.11607\/ijp.3947","article-title":"Screw-versus cement-retained implant prostheses: A systematic review of prosthodontic maintenance and complications","volume":"28","author":"Ma","year":"2015","journal-title":"Int J Prosthodont"},{"key":"R17-20260423","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1111\/j.1600-0501.2012.02538.x","article-title":"Cemented and screw-retained implant reconstructions: A systematic review of the survival and complication rates","volume":"23","author":"Sailer","year":"2012","journal-title":"Clin Oral Implants Res"},{"key":"R18-20260423","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1111\/jopr.12765","article-title":"Fracture resistance of titanium-based lithium disilicate and zirconia implant restorations","volume":"27","author":"Roberts","year":"2018","journal-title":"J Prosthodont"},{"key":"R19-20260423","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1016\/j.prosdent.2016.06.018","article-title":"Comparison of fracture strength and failure mode of different ceramic implant abutments","volume":"117","author":"Elsayed","year":"2017","journal-title":"J Prosthet Dent"},{"key":"R20-20260423","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1111\/clr.13034","article-title":"Effect of fatigue loading on the fracture strength and failure mode of lithium disilicate and zirconia implant abutments","volume":"29","author":"Elsayed","year":"2018","journal-title":"Clin Oral Implants Res"},{"key":"R21-20260423","doi-asserted-by":"crossref","first-page":"149","DOI":"10.15171\/joddd.2017.027","article-title":"Stress distribution pattern of screw-retained restorations with segmented vs. non-segmented abutments: A finite element analysis","volume":"11","author":"Aalaei","year":"2017","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"key":"R22-20260423","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1111\/j.1708-8208.2008.00120.x","article-title":"Cemented CeraOne and porcelain fused to TiAdapt abutment single-implant crown restorations: A 10-year comparative follow-up study","volume":"11","author":"Jemt","year":"2009","journal-title":"Clin Implant Dent Relat Res"},{"key":"R23-20260423","first-page":"312","article-title":"Customized titanium single-implant abutments: 2-year follow-up pilot study","volume":"11","author":"Jemt","year":"1998","journal-title":"Int J Prosthodont"},{"key":"R24-20260423","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/j.prosdent.2013.06.004","article-title":"Comparison of fracture resistance of pressable metal ceramic custom implant abutment with a commercially fabricated CAD\/CAM zirconia implant abutment","volume":"110","author":"Protopapadaki","year":"2013","journal-title":"J Prosthet Dent"},{"key":"R25-20260423","doi-asserted-by":"crossref","first-page":"188","DOI":"10.11607\/jomi.5929","article-title":"Clinical performance of one-piece, screw-retained implant crowns based on hand-veneered CAD\/CAM zirconia abutments after a mean follow-up period of 2.3 years","volume":"33","author":"Schnider","year":"2018","journal-title":"Int J Oral Maxillofac Implants"},{"key":"R26-20260423","doi-asserted-by":"crossref","first-page":"1308","DOI":"10.1111\/j.1600-0501.2010.02114.x","article-title":"Zirconia abutments for single-tooth implant restorations: A retrospective and clinical follow-up study","volume":"22","author":"Ekfeldt","year":"2011","journal-title":"Clin Oral Implants Res"},{"key":"R27-20260423","first-page":"626","article-title":"Evaluation of custom-made procera ceramic abutments for single-implant tooth replacement: A prospective 1-year follow-up study","volume":"16","author":"Henriksson","year":"2003","journal-title":"Int J Prosthodont"},{"key":"R28-20260423","first-page":"260","article-title":"Metal-free implant-supported single-tooth restorations. Part II: Hybrid abutment crowns and material selection","volume":"50","author":"Edelhoff","year":"2019","journal-title":"Quintessence Int"},{"key":"R29-20260423","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.jmbbm.2016.05.011","article-title":"Fracture strength of implant abutments after fatigue testing: A systematic review and meta-analysis","volume":"62","author":"Coray","year":"2016","journal-title":"J Mech Behav Biomed Mater"},{"key":"R30-20260423","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1016\/j.prosdent.2016.07.024","article-title":"Effect of internal hexagonal index on removal torque and tensile removal force of different Morse taper connection abutments","volume":"117","author":"Oliveira Silva","year":"2017","journal-title":"J Prosthet Dent"},{"key":"R31-20260423","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/jopr.12467","article-title":"Measurements of repeated tightening and loosening torque of seven different implant\/abutment connection design and their modifications: An in vitro study","volume":"27","author":"Butkevica","year":"2018","journal-title":"J Prosthodont"},{"key":"R32-20260423","doi-asserted-by":"crossref","first-page":"6137","DOI":"10.12659\/MSM.907840","article-title":"Clinical evaluation of complications in implant- supported dentures: A 4-year retrospective study","volume":"23","author":"\u00dclk\u00fc","year":"2017","journal-title":"Med Sci Monit"},{"key":"R33-20260423","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1111\/jerd.12494","article-title":"Mechanism of and factors associated with the loosening of the implant abutment screw: A review","volume":"31","author":"Huang","year":"2019","journal-title":"J Esthet Restor Dent"},{"key":"R34-20260423","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1111\/j.1600-0501.2007.01453.x","article-title":"A systematic review of the 5-year survival and complication rates of implant-supported single crowns","volume":"19","author":"Jung","year":"2008","journal-title":"Clin Oral Implants Res"},{"key":"R35-20260423","doi-asserted-by":"crossref","first-page":"21","DOI":"10.4047\/jap.2013.5.1.21","article-title":"Influence of the implant abutment types and the dynamic loading on initial screw loosening","volume":"5","author":"Kim","year":"2013","journal-title":"J Adv Prosthodont"},{"key":"R36-20260423","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1111\/j.1600-0501.2011.02165.x","article-title":"Torque removal evaluation of prosthetic screws after tightening and loosening cycles: An in vitro study","volume":"23","author":"Cardoso","year":"2012","journal-title":"Clin Oral Implants Res"},{"key":"R37-20260423","doi-asserted-by":"crossref","first-page":"317185","DOI":"10.1155\/2013\/317185","article-title":"The impact of thermocycling process on the dislodgement force of different endodontic cements","volume":"2013","author":"Saghiri","year":"2013","journal-title":"Biomed Res Int"},{"key":"R38-20260423","doi-asserted-by":"crossref","first-page":"e342","DOI":"10.1111\/jopr.12791","article-title":"An in vitro evaluation of the effect of various adhesives and surface treatments on bond strength of resin cement to polyetheretherketone","volume":"28","author":"Caglar","year":"2019","journal-title":"J Prosthodont"},{"key":"R39-20260423","doi-asserted-by":"crossref","first-page":"3931","DOI":"10.3390\/ijerph17113931","article-title":"Risk factors related to late failure of dental \u0131mplant-A systematic review of recent studies","volume":"17","author":"Do","year":"2020","journal-title":"Int J Environ Res Public Health"},{"key":"R41-20260423","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1016\/S0300-5712(98)00037-2","article-title":"Thermal cycling procedures for laboratory testing of dental restorations","volume":"27","author":"Gale","year":"1999","journal-title":"J Dent"},{"key":"R42-20260423","doi-asserted-by":"crossref","first-page":"128","DOI":"10.4047\/jkap.2012.50.2.128","article-title":"Evaluation of reverse torque value of abutment screws on CAD\/CAM custom-made implant abutments","volume":"50","author":"Lee","year":"2012","journal-title":"J Korean Acad Prosthodont"},{"key":"R43-20260423","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1097\/01.id.0000187902.68436.e4","article-title":"Analysis of changes in implant screws subject to occlusal loading: A preliminary analysis","volume":"14","author":"Yousef","year":"2005","journal-title":"Implant Dent"},{"key":"R44-20260423","doi-asserted-by":"crossref","first-page":"622","DOI":"10.11607\/jomi.7036","article-title":"Fracture resistance of titanium, zirconia, and ceramic-reinforced polyetheretherketone implant abutments supporting CAD\/CAM monolithic lithium disilicate ceramic crowns after aging","volume":"34","author":"Ats\u00fc","year":"2019","journal-title":"Int J Oral Maxillofac Implants"},{"key":"R46-20260423","doi-asserted-by":"crossref","first-page":"304","DOI":"10.1016\/S0022-3913(13)60306-6","article-title":"Fracture resistance of titanium and zirconia abutments: An in vitro study","volume":"109","author":"Foong","year":"2013","journal-title":"J Prosthet Dent"},{"key":"R47-20260423","first-page":"13","article-title":"Dental ceramics: Part I-An overview of composition, structure and properties","volume":"3","author":"Babu","year":"2015","journal-title":"Am J Mater Eng Technol"},{"key":"R48-20260423","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1055\/s-0040-1702260","article-title":"In vitro comparison of modes of failures among titanium and one- and two-piece zirconia abutment under static load","volume":"14","author":"Alqahtani","year":"2020","journal-title":"Eur J Dent"}],"container-title":["Nigerian Journal of Clinical Practice"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_772_23","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:58:09Z","timestamp":1786647489000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/njcp.njcp_772_23"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":45,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/njcp.njcp_772_23","relation":{},"ISSN":["1119-3077","2229-7731"],"issn-type":[{"value":"1119-3077","type":"print"},{"value":"2229-7731","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2023-11-03","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}