{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T10:50:55Z","timestamp":1789555855948,"version":"build-2803163510"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,7]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The objective was to compare the efficiency and assess postoperative complications of 2.00 mm unicortical locking plates and three-dimensional (3D) plates in surgical correction of uncomplicated mandibular fracture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A prospective cohort study of twenty patients of uncomplicated mandibular fractures, who were operated either by noncompression unicortical 2-mm locking mini-plate or by noncompression unicortical 2-mm 3D mini-plate, were enrolled and followed up for the study outcomes such as operative time, postoperative infection, and postoperative occlusion.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Majority of the patients (90%) were male who had road traffic accident. In 80% of cases, mandibular fracture site was parasymphysis. The mean operating time for 3D plates (43.20 min) was significantly lower than that for locking plates (54.82 min),\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001. All cases operated by 3D plates compared to 60% by locking mini-plates did not need intermaxillary fixation,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.025. The 80% of cases operated by 3D plates did not require postoperative occlusion correction compared to 30% in another group,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.01. For other parameters such as postoperative sensory disturbance, postoperative infection, incidence tooth damage, vertical displacement of mandible, feeling of plate after platting, and chewing efficiency after 1 week, there were no statistical significant differences between the two groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The outcome of 2.0mm 3D mini-plate is better in terms of operating time required, post-operative need of intermaxillary fixation and occlusal correction. While the outcome is similar to the use of non-compression unicortical 2.00mm locking miniplate in parameters like infection rate and incidence of tooth damage etc.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/njms.njms_53_19","type":"journal-article","created":{"date-parts":[[2020,12,17]],"date-time":"2020-12-17T08:40:48Z","timestamp":1608194448000},"page":"263-269","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Comparative study of outcomes between locking plates and three-dimensional plates in mandibular fractures"],"prefix":"10.4103","volume":"11","author":[{"given":"Shaikh","family":"Amjad","sequence":"first","affiliation":[{"name":"Department of Dentistry, Indian Institute of Medical Sciences and Research, Jalna, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"MD","family":"Kalim Ansari","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Aligarh Muslim University, Aligarh, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Syed S.","family":"Ahmad","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Aligarh Muslim University, Aligarh, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tabishur","family":"Rahman","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Aligarh Muslim University, Aligarh, Uttar Pradesh, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,12,16]]},"reference":[{"key":"R1-20250920","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1001\/jamafacial.2018.1836","article-title":"Risk factors associated with complications after treatment of mandible fractures","volume":"21","author":"Hsieh","year":"2019","journal-title":"JAMA Facial Plast Surg"},{"key":"R2-20250920","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s10006-017-0642-1","article-title":"Comparison of 3D plate and locking plate in treatment of mandibular fracture \u2013 A clinical study","volume":"21","author":"Aggarwal","year":"2017","journal-title":"Oral Maxillofac Surg"},{"key":"R4-20250920","first-page":"9","article-title":"Airway management of the patient with maxillofacial trauma: Review of the literature and suggested clinical approach","author":"Barak","year":"2015","journal-title":"Biomed Res Int"},{"key":"R5-20250920","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1055\/s-0029-1202591","article-title":"Choice of internal rigid fixation materials in the treatment of facial fractures","volume":"2","author":"Gilardino","year":"2009","journal-title":"Craniomaxillofac Trauma Reconstr"},{"key":"R7-20250920","first-page":"20","article-title":"Efficacy of 3-dimensional plates over Champy's miniplates in mandibular anterior fractures","volume":"6","author":"Barde","year":"2014","journal-title":"J Int Oral Health"},{"key":"R8-20250920","doi-asserted-by":"crossref","first-page":"972","DOI":"10.1007\/s12663-015-0764-7","article-title":"Bite force evaluation of conventional plating system versus locking plating system for mandibular fracture","volume":"14","author":"Giri","year":"2015","journal-title":"J Maxillofac Oral Surg"},{"key":"R9-20250920","first-page":"353","article-title":"The value of 3-dimensional plates in maxillofacial surgery","volume":"93","author":"Farmand","year":"1992","journal-title":"Rev Stomatol Chir Maxillofac"},{"key":"R10-20250920","doi-asserted-by":"crossref","first-page":"42e","DOI":"10.1097\/01.prs.0000177687.83247.27","article-title":"Two hundred ninety-four consecutive facial fractures in an urban trauma center: Lessons learned","volume":"116","author":"Kelley","year":"2005","journal-title":"Plast Reconstr Surg"},{"key":"R11-20250920","doi-asserted-by":"crossref","first-page":"154","DOI":"10.4103\/2231-0746.119231","article-title":"Conventional 2.0 mm miniplates versus 3-D plates in mandibular fractures","volume":"3","author":"Sadhwani","year":"2013","journal-title":"Ann Maxillofac Surg"},{"key":"R12-20250920","doi-asserted-by":"crossref","first-page":"1319","DOI":"10.1053\/joms.2002.35732","article-title":"Does plate adaptation affect stability. A biomechanical comparison of locking and nonlocking plates?","volume":"60","author":"Haug","year":"2002","journal-title":"J Oral Maxillofac Surg"},{"key":"R13-20250920","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1016\/j.joms.2008.09.022","article-title":"Five-year retrospective study of mandibular fractures in Freiburg, Germany: Incidence, etiology, treatment, and complications","volume":"67","author":"Bormann","year":"2009","journal-title":"J Oral Maxillofac Surg"},{"key":"R14-20250920","doi-asserted-by":"crossref","first-page":"241","DOI":"10.13005\/bpj\/480","article-title":"Three dimensional titanium mini plates in management of mandibular fractures","volume":"7","author":"Balakrishnan","year":"2014","journal-title":"Biomed Pharmacol J"},{"key":"R15-20250920","doi-asserted-by":"crossref","first-page":"1711","DOI":"10.1097\/01.PRS.0000142477.77232.F7","article-title":"Treatment of mandibular angle fractures with a matrix miniplate: A preliminary report","volume":"114","author":"Feledy","year":"2004","journal-title":"Plast Reconstr Surg"},{"key":"R16-20250920","doi-asserted-by":"crossref","first-page":"1758","DOI":"10.1016\/j.joms.2007.03.013","article-title":"Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle","volume":"65","author":"Zix","year":"2007","journal-title":"J Oral Maxillofac Surg"},{"key":"R17-20250920","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1007\/s12663-011-0267-0","article-title":"Three dimensional titanium mini plates in oral and maxillofacial surgery: A prospective clinical trial","volume":"11","author":"Mittal","year":"2012","journal-title":"J Maxillofac Oral Surg"},{"key":"R18-20250920","first-page":"1006","article-title":"Titanium three dimensional miniplate versus conventional titanium miniplate in fixation of anterior mandibular fractures","volume":"9","author":"Khalifa","year":"2012","journal-title":"LSJ"},{"key":"R19-20250920","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1016\/S0278-2391(03)00731-6","article-title":"Mandibulotomy fixation: A laboratory analysis","volume":"61","author":"Engroff","year":"2003","journal-title":"J Oral Maxillofac Surg"},{"key":"R20-20250920","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1053\/joms.2002.33110","article-title":"Use of a 2.0-mm locking plate\/screw system for mandibular fracture surgery","volume":"60","author":"Ellis","year":"2002","journal-title":"J Oral Maxillofac Surg"},{"key":"R21-20250920","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.joms.2004.03.018","article-title":"Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate","volume":"63","author":"Guimond","year":"2005","journal-title":"J Oral Maxillofac Surg"},{"key":"R22-20250920","first-page":"284","article-title":"Versatility of titanium 3D plate in comparison with conventional miniplate fixation for the management of mandibular fracture","volume":"11","author":"Malhotra","year":"2012","journal-title":"JMOS"},{"key":"R23-20250920","first-page":"1613","article-title":"Small and large titanium plates are equally effective for treating mandible fractures","volume":"70","author":"Bouloux","year":"2012","journal-title":"JOMS"},{"key":"R24-20250920","first-page":"21","article-title":"Titanium miniplate osteosynthesis of mandibular fractures","volume":"1","author":"Kumar","year":"2012","journal-title":"IJDS"},{"key":"R25-20250920","first-page":"14","article-title":"Three dimensional miniplate rigid fixation in fracture mandible","volume":"6","author":"Parmar","year":"2007","journal-title":"J Maxillofac Oral Surg"}],"container-title":["National Journal of Maxillofacial Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/njms.NJMS_53_19","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:44:31Z","timestamp":1787773471000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/njms.NJMS_53_19"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.4103\/njms.njms_53_19","relation":{},"ISSN":["0975-5950","2229-3418"],"issn-type":[{"value":"0975-5950","type":"print"},{"value":"2229-3418","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7]]},"assertion":[{"value":"2019-08-30","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-05-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}