{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T20:06:38Z","timestamp":1787169998773,"version":"build-2736575974"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>The objective of this study was to evaluate the thyroid glands' radiation dose and the risk of thyroid cancer induction from head or neck computed tomography (CT) examinations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      In a prospective study, we evaluated all participants of all ages and sex referred for Head or Neck CT Scan at the University College Hospital, Ibadan and Me Cure Healthcare Limited, Ibadan, Oyo State, Nigeria. Thyroid radiation dose was estimated with impact scan calculator, and real-time dose measurement with thermoluminescent badge dosimeters (TLDs). Data were analysed and\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05 was considered statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      One hundred and sixty-three participants (128 adults and 35 children) participated in the study. In most participants (74%), the tube voltage was 120 kVp. The estimated median thyroid gland dose by the imPACT scan calculator was 4.95 mGy (range = 1.20\u201330.0 mGy) and 4.40 mGy (range = 3.0\u20135.10 mGy), while the real-time dose measured by the TLD was 4.79 mGy (range = 1.73\u201396.7 mGy) and 2.33 mGy (range = 1.20\u20133.73 mGy) at Centre A and B, respectively. The estimated median thyroid cancer risk was 2.88 \u00d7 10\n                      <jats:sup>\u22126<\/jats:sup>\n                      (maximum range of 52 \u00d7 10\n                      <jats:sup>\u22126<\/jats:sup>\n                      ) at centre A and a median value of 3.20 \u00d7 10\n                      <jats:sup>\u22126<\/jats:sup>\n                      with a cancer risk estimate that may reach 17.9 \u00d7 10\n                      <jats:sup>\u22126<\/jats:sup>\n                      recorded at centre B, compared to a cumulative thyroid cancer risk of 0.12 \u00d7 10\n                      <jats:sup>\u22125<\/jats:sup>\n                      among the general Nigerian population.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Scanner specifications and technique may significantly contribute to variations seen in thyroid radiation doses. There may be a need to optimise centre protocols and apply dose reference levels for head and neck CT examinations to reduce thyroid cancer risk in Nigeria.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/npmj.npmj_611_21","type":"journal-article","created":{"date-parts":[[2021,11,29]],"date-time":"2021-11-29T09:51:31Z","timestamp":1638179491000},"page":"278-284","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Thyroid Dose and Cancer Risk from Head and Neck Computed Tomography at Two Selected Centres in Nigeria"],"prefix":"10.4103","volume":"28","author":[{"given":"Olufisayo Olalekan","family":"Awe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel Ibhade","family":"Obed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ademola Joseph","family":"Adekanmi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Godwin I.","family":"Ogbole","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alaba Tolulope","family":"Agbele","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-8-20240908","doi-asserted-by":"crossref","first-page":"2078","DOI":"10.1001\/archinternmed.2009.427","article-title":"Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer","volume":"169","author":"Smith-Bindman","year":"2009","journal-title":"Arch Intern Med"},{"key":"R2-8-20240908","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1259\/bjr.71.841.9534691","article-title":"CT scanner dosimetry","volume":"71","author":"Shrimpton","year":"1998","journal-title":"Br J Radiol"},{"key":"R3-8-20240908","doi-asserted-by":"crossref","first-page":"303","DOI":"10.2214\/ajr.176.2.1760303","article-title":"Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large Children's Hospital","volume":"176","author":"Donnelly","year":"2001","journal-title":"AJR Am J Roentgenol"},{"key":"R4-8-20240908","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","article-title":"Estimated risks of radiation","volume":"176","author":"Brenner","year":"2001","journal-title":"Am Roentgen Ray Soc"},{"key":"R5-8-20240908","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1118\/1.3544658","article-title":"Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations","volume":"38","author":"Lee","year":"2011","journal-title":"Med Phys"},{"key":"R8-8-20240908","doi-asserted-by":"crossref","first-page":"2530","DOI":"10.18203\/2320-6012.ijrms20192877","article-title":"Evaluation of scatter radiation to the thyroid gland attributable to brain computed tomography scan in Port Harcourt, Nigeria","volume":"7","author":"Robinson","year":"2019","journal-title":"Int J Res Med Sci"},{"key":"R9-8-20240908","first-page":"165","article-title":"Computed tomography organ dose determination using ImPACT simulation software: Our findings in South-West Nigeria","volume":"2","author":"Akpochafor","year":"2017","journal-title":"Eurasian J Med Oncol"},{"key":"R10-8-20240908","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1088\/1361-6498\/aaaaf8","article-title":"Diagnostic reference levels for common computed tomography (CT) examinations: Results from the first Nigerian nationwide dose survey","volume":"38","author":"Ekpo","year":"2018","journal-title":"J Radiol Prot"},{"key":"R11-8-20240908","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1093\/rpd\/ncv188","article-title":"Computed tomography dose index for head CT in Northern Nigeria","volume":"165","author":"Garba","year":"2015","journal-title":"Radiat Prot Dosimetry"},{"key":"R12-8-20240908","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4103\/1115-1474.128072","article-title":"Radiation doses in computed tomography: Need for optimization and application of dose reference levels in Nigeria","volume":"21","author":"Ogbole","year":"2014","journal-title":"West Afr J Radiol"},{"key":"R14-8-20240908","doi-asserted-by":"crossref","first-page":"e323","DOI":"10.1016\/S2214-109X(14)70227-X","article-title":"Global causes of maternal death: A WHO systematic analysis","volume":"2","author":"Say","year":"2014","journal-title":"Lancet Glob Health"},{"key":"R16-8-20240908","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/S0969-8043(98)00024-4","article-title":"Dosimetry for optimisation of patient protection in computed tomography","volume":"50","author":"Jessen","year":"1999","journal-title":"Appl Radiat Isot"},{"key":"R17-8-20240908","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1093\/rpd\/ncv127","article-title":"Russian practical guidance on radiological support for justification of X-ray and nuclear medicine examinations","volume":"165","author":"Balonov","year":"2015","journal-title":"Radiat Prot Dosimetry"},{"key":"R18-8-20240908","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.icrp.2012.06.002","article-title":"Effective dose and risks from medical X-ray procedures","volume":"41","author":"Balonov","year":"2012","journal-title":"Ann ICRP"},{"key":"R19-8-20240908","doi-asserted-by":"crossref","first-page":"902","DOI":"10.4329\/wjr.v8.i12.902","article-title":"Computed tomography and patient risk: Facts, perceptions and uncertainties","volume":"8","author":"Power","year":"2016","journal-title":"World J Radiol"},{"key":"R20-8-20240908","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1259\/bjr\/93277434","article-title":"National survey of doses from CT in the UK: 2003","volume":"79","author":"Shrimpton","year":"2006","journal-title":"Br J Radiol"},{"key":"R21-8-20240908","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.jacr.2013.05.032","article-title":"CT scan parameters and radiation dose: Practical advice for radiologists","volume":"10","author":"Raman","year":"2013","journal-title":"J Am Coll Radiol"},{"key":"R23-8-20240908","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1093\/rpd\/nct090","article-title":"Computation of thyroid doses and carcinogenic radiation risks to patients undergoing neck CT examinations","volume":"156","author":"Huda","year":"2013","journal-title":"Radiat Prot Dosimetry"},{"key":"R24-8-20240908","doi-asserted-by":"crossref","first-page":"9475","DOI":"10.1038\/s41598-020-66366-2","article-title":"Individual calculation of effective dose and risk of malignancy based on monte carlo simulations after whole body computed tomography","volume":"10","author":"Kopp","year":"2020","journal-title":"Sci Rep"},{"key":"R26-8-20240908","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.2214\/AJR.14.13102","article-title":"Thyroid doses and risks to adult patients undergoing neck CT examinations","volume":"204","author":"Tipnis","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"R27-8-20240908","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1002\/mp.12012","article-title":"Advocating for use of the ALARA principle in the context of medical imaging fails to recognize that the risk is hypothetical and so serves to reinforce patients' fears of radiation","volume":"44","author":"Siegel","year":"2017","journal-title":"Med Phys"}],"container-title":["Nigerian Postgraduate Medical Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/npmj.npmj_611_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:16:20Z","timestamp":1787166980000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/npmj.npmj_611_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/npmj.npmj_611_21","relation":{},"ISSN":["1117-1936"],"issn-type":[{"value":"1117-1936","type":"print"}],"subject":[],"published":{"date-parts":[[2021,10]]}}}