{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T13:19:24Z","timestamp":1787750364824,"version":"build-2784847793"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T00:00:00Z","timestamp":1777593600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,5]]},"abstract":"<jats:title>Abstract:<\/jats:title>\n                  <jats:sec>\n                    <jats:title>CONTEXT:<\/jats:title>\n                    <jats:p>Uncorrected refractive errors are the most common cause of visual impairment and global blindness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>AIMS:<\/jats:title>\n                    <jats:p>This study aims to assess the accuracy of refractive error measurements using streak retinoscopy and autorefraction, both with and without administering cycloplegics, in children aged 4\u201310 years.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>SETTINGS AND DESIGN:<\/jats:title>\n                    <jats:p>This study is an analytical observational research with a cross-sectional design.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>SUBJECTS AND METHODS:<\/jats:title>\n                    <jats:p>This study was conducted at an eye clinic from January 2020 to August 2020, with 90 subjects. The examination utilized 1% cyclopentolate cycloplegia administered twice within 1 h, along with retinoscopy and autorefractors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>STATISTICAL ANALYSIS USED:<\/jats:title>\n                    <jats:p>The data were analyzed using the Wilcoxon signed-rank test.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      The study results indicate that (1) there was no significant difference in the mean spherical equivalent (SE) before cycloplegia between the two instruments (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.630); (2) a significant difference in mean SE after cycloplegia was observed for both instruments (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001); (3) significant differences in mean SE after cycloplegia were noted for both instruments in cases of compound myopic astigmatism (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001), compound hyperopic astigmatism (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.007), and mixed astigmatism (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.001); and (4) examination of all subjects showed undercorrection of autorefractometry results compared to those of retinoscopy.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Retinoscopy and autorefractors yield different results for refractive error correction after cycloplegia. Therefore, autorefractor examination with cycloplegia cannot be considered a substitute for retinoscopy with cycloplegia.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ojo.ojo_100_25","type":"journal-article","created":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T02:00:09Z","timestamp":1782266409000},"page":"232-238","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of refractive examination results in children with and without cycloplegia using retinoscopy and autorefractors"],"prefix":"10.4103","volume":"19","author":[{"given":"Delvi Indera","family":"Mayasari","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulfah","family":"Rimayanti","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Hasanuddin University, Makassar, Indonesia"},{"name":"School of Medicine, Universitas Islam Negeri Alauddin Makassar, Makassar, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marlyanti Nur","family":"Rahmah","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Universitas Muslim Indonesia, Makassar, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Purnamanita","family":"Syawal","sequence":"additional","affiliation":[{"name":"Makassar Eye Hospital, Makassar, Indonesia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,6,24]]},"reference":[{"key":"R2-20260624","first-page":"170","article-title":"An overview of refractive errors in pediatric patients aged 6-12 years at the Refraction and Contact Lens Division of the Eye Clinic, Sanglah General Hospital in 2014","volume":"6","author":"Mihartari","year":"2017","journal-title":"E J Med"},{"key":"R4-20260624","doi-asserted-by":"crossref","first-page":"40","DOI":"10.36351\/pjo.v41i1.1897","article-title":"Visual acuity and refractive errors in toddlers","volume":"41","author":"Rimayanti","year":"2025","journal-title":"Pak J Ophthalmol"},{"key":"R5-20260624","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/S1888-4296(11)70041-3","article-title":"Refractive errors among school children in Jhapa, Nepal","volume":"4","author":"Shrestha","year":"2011","journal-title":"J Optom"},{"key":"R6-20260624","doi-asserted-by":"crossref","first-page":"221","DOI":"10.4103\/2008-322X.170360","article-title":"Accuracy and repeatability of refractive error measurements by photorefractometry","volume":"10","author":"Rajavi","year":"2015","journal-title":"J Ophthalmic Vis Res"},{"key":"R7-20260624","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1111\/cxo.12375","article-title":"A comparison of cycloplegic autorefraction and retinoscopy in Indian children","volume":"100","author":"Guha","year":"2017","journal-title":"Clin Exp Optom"},{"key":"R8-20260624","first-page":"249","article-title":"Difference of refraction values between standard autorefractometry and plusoptix","volume":"60","author":"Bogd\u0103nici","year":"2016","journal-title":"Rom J Ophthalmol"},{"key":"R9-20260624","first-page":"806","article-title":"Accuracy of noncycloplegic refraction in primary school children in Southern Thailand","volume":"92","author":"Funarunart","year":"2009","journal-title":"J Med Assoc Thai"},{"key":"R12-20260624","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/S2221-6189(13)60096-7","article-title":"Incidence of refractive errors in children 3 to 9 years of age in the city of Tetovo, Macedonia","volume":"2","author":"Mahmudi","year":"2013","journal-title":"J. Acute Dis"},{"key":"R13-20260624","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1111\/cxo.12829","article-title":"Effect of cycloplegia on the measurement of refractive error in Chinese children","volume":"102","author":"Li","year":"2019","journal-title":"Clin Exp Optom"},{"key":"R14-20260624","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1097\/OPX.0000000000000339","article-title":"Short-term refractive change and ocular parameter changes after cycloplegia","volume":"91","author":"Cheng","year":"2014","journal-title":"Optom Vis Sci"},{"key":"R15-20260624","doi-asserted-by":"crossref","first-page":"101","DOI":"10.4103\/jovr.jovr_196_17","article-title":"Effect of cycloplegia on corneal biometrics and refractive state","volume":"13","author":"Bagheri","year":"2018","journal-title":"J Ophthalmic Vis Res"},{"key":"R16-20260624","doi-asserted-by":"crossref","first-page":"4730","DOI":"10.3390\/ijerph16234730","article-title":"Distribution of refractive errors among healthy infants and young children between the age of 6 to 36 months in Kuala Lumpur, Malaysia-a pilot study","volume":"16","author":"Yahya","year":"2019","journal-title":"Int J Environ Res Public Health"},{"key":"R17-20260624","article-title":"The effect of cycloplegics on refraction results in children under 10 years old [Thesis]","author":"Novianti","year":"2020","journal-title":"Hasanuddin University, Makassar, Indonesia"},{"key":"R18-20260624","first-page":"740","article-title":"Comparison of autorefractometer, retinoscope and subjective method in myopic and hypermetropic patients","volume":"4","author":"Ganger","year":"2017","journal-title":"IJCMR"},{"key":"R19-20260624","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1136\/bjophthalmol-2017-311594","article-title":"Overestimation of hyperopia with autorefraction compared with retinoscopy under cycloplegia in school-age children","volume":"102","author":"Hashemi","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"R20-20260624","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1111\/aos.12642","article-title":"Cycloplegic refraction is the gold standard for epidemiological studies","volume":"93","author":"Morgan","year":"2015","journal-title":"Acta Ophthalmol"},{"key":"R21-20260624","doi-asserted-by":"crossref","first-page":"129","DOI":"10.2147\/OPTO.S303286","article-title":"Agreement between retinoscopy, autorefractometry and subjective refraction for determining refractive errors in Congolese children","volume":"13","author":"Mukash","year":"2021","journal-title":"Clin Optom (Auckl)"},{"key":"R22-20260624","first-page":"612728","article-title":"Responses of the ocular anterior segment and refraction to 0.5% tropicamide in Chinese school-aged children of Myopia, Emmetropia, and hyperopia","author":"Yuan","year":"2015","journal-title":"J Ophthalmol 2015"},{"key":"R23-20260624","article-title":"Cycloplegic refraction by 1% cyclopentolate in young adults: Is it the gold standard?The Anyang university students eye study (AUSES)","author":"Sun","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"R24-20260624","first-page":"NC09","article-title":"A study of proportion of pseudomyopia in hyperopia","volume":"14","author":"Shetty","year":"2020","journal-title":"JOVR"},{"key":"R25-20260624","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.optom.2017.09.001","article-title":"Comparison of cyclopentolate versus tropicamide cycloplegia: A systematic review and meta-analysis","volume":"11","author":"Yazdani","year":"2018","journal-title":"J Optom"}],"container-title":["Oman Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ojo.ojo_100_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T12:27:31Z","timestamp":1787747251000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ojo.ojo_100_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/ojo.ojo_100_25","relation":{},"ISSN":["0974-620X","0974-7842"],"issn-type":[{"value":"0974-620X","type":"print"},{"value":"0974-7842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5]]},"assertion":[{"value":"2025-03-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}