{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T20:24:53Z","timestamp":1790799893855,"version":"4.1.0"},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T00:00:00Z","timestamp":1746057600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,5]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Implantable collamer lens (ICL) implantation has gained popularity as a surgical option for the correction of high myopia. This study aimed to evaluate the visual outcomes, patient satisfaction, and safety of ICL implantation by combining objective and subjective parameters for a comprehensive assessment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>This prospective, interventional study included 67 eyes from 37 patients who underwent ICL implantation. Visual acuity, refractive outcomes, anterior chamber depth, ICL vault, endothelial cell density, intraocular pressure, and patient satisfaction using the Visual Function Questionnaire-25 (VFQ-25) were assessed preoperatively and at various postoperative time points up to 12 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      At 12 months postoperatively, the mean uncorrected distance visual acuity improved to 0.10 \u00b1 0.08 LogMAR, and the mean corrected distance visual acuity improved to 0.04 \u00b1 0.05 LogMAR. The mean spherical equivalent decreased from \u221210.57 \u00b1 2.22 D preoperatively to \u22120.10 \u00b1 0.25 D, with 95.5% of eyes within \u00b10.50 D of the target refraction. The mean ICL vault was stable at 625 \u00b1 80 \u03bcm, and no significant endothelial cell loss or complications were observed. The mean composite VFQ-25 score improved significantly from 72.87 \u00b1 11.23 preoperatively to 93.39 \u00b1 4.68 at 12 months postoperatively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>This study demonstrates that ICL implantation is a safe, effective, and predictable option for the correction of high myopia, providing excellent visual outcomes, refractive stability, and significant improvements in patient satisfaction and quality of life. The combination of objective and subjective parameters provides a comprehensive assessment of surgical success and patient-reported outcomes.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/ojo.ojo_171_24","type":"journal-article","created":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T07:00:38Z","timestamp":1750748438000},"page":"187-192","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Objective and subjective outcomes following implantable collamer lens (ICL) implantation for the correction of myopia"],"prefix":"10.4103","volume":"18","author":[{"given":"Gaurav","family":"Kapoor","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Armed Forces Medical College, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vijay Kumar","family":"Sharma","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Armed Forces Medical College, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prabhjot","family":"Singh","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Armed Forces Medical College, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepti","family":"Sahran","sequence":"additional","affiliation":[{"name":"Department of Hospital Administration, Armed Forces Medical College, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sankalp","family":"Seth","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Command Hospital Southern Command, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vikas","family":"Ambiya","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Armed Forces Medical College, Pune, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nidhi","family":"Kalra","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, 151 Base Hospital, Guwahati, Assam, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Avinash","family":"Mishra","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Military Hospital, Jalandhar, Punjab, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,6,24]]},"reference":[{"key":"R1-20250628","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1016\/j.ophtha.2016.01.006","article-title":"Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050","volume":"123","author":"Holden","year":"2016","journal-title":"Ophthalmology"},{"key":"R2-20250628","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1111\/j.1475-1313.2005.00298.x","article-title":"Myopia and associated pathological complications","volume":"25","author":"Saw","year":"2005","journal-title":"Ophthalmic Physiol Opt"},{"key":"R3-20250628","doi-asserted-by":"crossref","first-page":"2347","DOI":"10.1097\/IAE.0000000000001489","article-title":"Overview of the complications of high myopia","volume":"37","author":"Ikuno","year":"2017","journal-title":"Retina"},{"key":"R4-20250628","doi-asserted-by":"crossref","first-page":"169","DOI":"10.3928\/1081597X-20190118-01","article-title":"Five-year follow-up of correction of myopia: Posterior chamber phakic intraocular lens with a central port design","volume":"35","author":"Alfonso","year":"2019","journal-title":"J Refract Surg"},{"key":"R5-20250628","doi-asserted-by":"crossref","first-page":"2427","DOI":"10.2147\/OPTH.S188785","article-title":"The implantable collamer lens with a central port: Review of the literature","volume":"12","author":"Packer","year":"2018","journal-title":"Clin Ophthalmol"},{"key":"R6-20250628","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1136\/bjophthalmol-2017-310164","article-title":"Posterior chamber phakic intraocular lens implantation: Comparative, multicentre study in 351 eyes with low-to-moderate or high myopia","volume":"102","author":"Kamiya","year":"2018","journal-title":"Br J Ophthalmol"},{"key":"R7-20250628","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/j.ajo.2013.11.006","article-title":"Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia","volume":"157","author":"Igarashi","year":"2014","journal-title":"Am J Ophthalmol"},{"key":"R8-20250628","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1001\/archopht.119.7.1050","article-title":"Development of the 25-item national eye institute visual function questionnaire","volume":"119","author":"Mangione","year":"2001","journal-title":"Arch Ophthalmol"},{"key":"R9-20250628","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1001\/archopht.116.11.1496","article-title":"Psychometric properties of the National Eye Institute Visual Function Questionnaire (NEI-VFQ). NEI-VFQ field test investigators","volume":"116","author":"Mangione","year":"1998","journal-title":"Arch Ophthalmol"},{"key":"R10-20250628","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1016\/j.jcrs.2008.11.038","article-title":"Catquest-9SF patient outcomes questionnaire: Nine-item short-form rasch-scaled revision of the catquest questionnaire","volume":"35","author":"Lundstr\u00f6m","year":"2009","journal-title":"J Cataract Refract Surg"},{"key":"R11-20250628","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1016\/j.ajo.2005.07.075","article-title":"Evaluation of quality of life for patients with glaucoma","volume":"141","author":"Spaeth","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R12-20250628","doi-asserted-by":"crossref","first-page":"1102","DOI":"10.1097\/OPX.0000000000001143","article-title":"Patient-reported outcomes for assessment of quality of life in refractive error: A systematic review","volume":"94","author":"Kandel","year":"2017","journal-title":"Optom Vis Sci"},{"key":"R13-20250628","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1016\/j.jcrs.2004.12.059","article-title":"Changes in quality of life after laser in situ keratomileusis for myopia","volume":"31","author":"Garamendi","year":"2005","journal-title":"J Cataract Refract Surg"},{"key":"R14-20250628","doi-asserted-by":"crossref","first-page":"2295","DOI":"10.1016\/j.ophtha.2010.03.055","article-title":"Quality of life in high myopia before and after implantable Collamer lens implantation","volume":"117","author":"Ieong","year":"2010","journal-title":"Ophthalmology"},{"key":"R15-20250628","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1186\/s12886-018-0805-3","article-title":"Refractive outcomes and optical quality after implantation of posterior chamber phakic implantable collamer lens with a central hole (ICL V4c)","volume":"18","author":"Miao","year":"2018","journal-title":"BMC Ophthalmol"},{"key":"R16-20250628","doi-asserted-by":"crossref","first-page":"e288","DOI":"10.1111\/aos.14599","article-title":"Posterior-chamber phakic implantable collamer lenses with a central port: A review","volume":"99","author":"Mont\u00e9s-Mic\u00f3","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"R17-20250628","doi-asserted-by":"crossref","first-page":"e3270","DOI":"10.1097\/MD.0000000000003270","article-title":"Long-term comparison of posterior chamber phakic intraocular lens with and without a central hole (Hole ICL and Conventional ICL) implantation for moderate to high myopia and myopic astigmatism: Consort-compliant article","volume":"95","author":"Shimizu","year":"2016","journal-title":"Medicine (Baltimore)"}],"container-title":["Oman Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/ojo.ojo_171_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:35:32Z","timestamp":1787067332000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/ojo.ojo_171_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5]]},"references-count":17,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/ojo.ojo_171_24","relation":{},"ISSN":["0974-620X","0974-7842"],"issn-type":[{"value":"0974-620X","type":"print"},{"value":"0974-7842","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5]]},"assertion":[{"value":"2024-06-11","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-05-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}