{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,5]],"date-time":"2026-09-05T02:54:23Z","timestamp":1788576863454,"version":"build-2803163510"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2018,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>Several devices are available to take care of difficult airway, but C-MAC D-Blade has scant evidence of its use in nasotracheal intubation in a difficult airway scenario.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aims and Objectives:<\/jats:title>\n                    <jats:p>\n                      We compared the C-MAC D-Blade videolaryngoscope\n                      <jats:sup>\u2122<\/jats:sup>\n                      , and the standard Macintosh laryngoscope for nasal intubation in patients with difficult airways selected by El-Ganzouri risk index using parameters of time and attempts required for intubation, glottic view in terms of Cormack\u2013Lehane grade, ease of intubation, success rate, use of accessory maneuvers, incidence of complications, and hemodynamic changes.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>One hundred American Society of Anesthesiologists (ASA) I\u2013III patients aged 20\u201370 years with EGRI score 1\u2013\u22647 scheduled for head and neck surgery requiring nasal intubation. ASA IV patients, patients with mouth opening &lt;2.5 cm, patients difficult to mask ventilate, and patients with hyperkalemia and history of malignant hyperthermia were excluded from the study. Primary outcome was time taken to intubation, and secondary outcomes were a number of attempts, glottic view in terms of C\/L grade, use of accessory maneuvers, success rate, incidence of trauma, ease of intubation, and hemodynamic changes before and after intubation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Time required for intubation was less (39.56 \u00b1 15.65 s) in Group C than in Group M (50.34 \u00b1 15.65 s). Cormack\u2013Lehane Grade I and II view were more in C-MAC D-Blade group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). Success rate and ease of intubation were found to be more in C-MAC D-Blade group than in Macintosh group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). A number of attempts and incidence of complications such as trauma, bleeding, and failed intubation were greater in Macintosh group than in C-MAC D-Blade group. Hemodynamic changes were observed to be comparable in both the groups.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      C-MAC D-Blade videolaryngoscope\n                      <jats:sup>\u2122<\/jats:sup>\n                      is a better tool in anesthetic management of difficult airway for nasal intubation compared to conventional Macintosh laryngoscope.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/sja.sja_239_17","type":"journal-article","created":{"date-parts":[[2018,1,8]],"date-time":"2018-01-08T01:07:11Z","timestamp":1515373631000},"page":"35-41","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":33,"title":["A randomized controlled trial comparing C Mac D Blade and Macintosh laryngoscope for nasotracheal intubation in patients undergoing surgeries for head and neck cancer"],"prefix":"10.4103","volume":"12","author":[{"given":"Hrishikesh","family":"Hazarika","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Rajiv Gandhi Cancer Institute and Research Centre, Sector V, Rohini, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anudeep","family":"Saxena","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Rajiv Gandhi Cancer Institute and Research Centre, Sector V, Rohini, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pradeep","family":"Meshram","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Rajiv Gandhi Cancer Institute and Research Centre, Sector V, Rohini, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ajay","family":"Kumar Bhargava","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Rajiv Gandhi Cancer Institute and Research Centre, Sector V, Rohini, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250920","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1046\/j.1365-2044.2003.03034.x","article-title":"Nasotracheal intubation for head and neck surgery","volume":"58","author":"Hall","year":"2003","journal-title":"Anaesthesia"},{"key":"R2-20250920","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","article-title":"Difficult tracheal intubation in obstetrics","volume":"39","author":"Cormack","year":"1984","journal-title":"Anaesthesia"},{"key":"R4-20250920","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1111\/j.1399-6576.2010.02285.x","article-title":"Video-laryngoscopes in the adult airway management: A topical review of the literature","volume":"54","author":"Niforopoulou","year":"2010","journal-title":"Acta Anaesthesiol Scand"},{"key":"R5-20250920","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1093\/bja\/aes333","article-title":"Clinical evaluation of the C-MAC D-Blade videolaryngoscope in severely obese patients: A pilot study","volume":"109","author":"Cattano","year":"2012","journal-title":"Br J Anaesth"},{"key":"R6-20250920","doi-asserted-by":"crossref","first-page":"314","DOI":"10.4097\/kjae.2010.59.5.314","article-title":"Comparison of the laryngeal view during intubation using Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization and mouth opening limitation","volume":"59","author":"Koh","year":"2010","journal-title":"Korean J Anesthesiol"},{"key":"R7-20250920","doi-asserted-by":"crossref","first-page":"R103","DOI":"10.1186\/cc11384","article-title":"Endotracheal intubation using the C-MAC\u00ae video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU","volume":"16","author":"Noppens","year":"2012","journal-title":"Crit Care"},{"key":"R8-20250920","first-page":"962","article-title":"Nasal endotracheal intubation using GlideScope","volume":"56","author":"Hirabayashi","year":"2007","journal-title":"Masui"},{"key":"R9-20250920","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1111\/j.1365-2044.2011.06943.x","article-title":"Easy and difficult nasal intubation \u2013 a randomised comparison of Macintosh vs. Airtraq\u00ae laryngoscopes","volume":"67","author":"St. Mont","year":"2012","journal-title":"Anaesthesia"},{"key":"R10-20250920","doi-asserted-by":"crossref","first-page":"382","DOI":"10.1213\/ANE.0b013e31820553fb","article-title":"First clinical evaluation of the C-MAC D-Blade videolaryngoscope during routine and difficult intubation","volume":"112","author":"Cavus","year":"2011","journal-title":"Anesth Analg"},{"key":"R11-20250920","doi-asserted-by":"crossref","first-page":"422","DOI":"10.4103\/0019-5049.100840","article-title":"Facilitated nasotracheal intubation in patient with restricted mouth opening aided by D-blade of C-Mac videolaryngoscope and Schroeder's directional stylet","volume":"56","author":"Al-Jadidi","year":"2012","journal-title":"Indian J Anaesth"},{"key":"R12-20250920","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1016\/j.annemergmed.2010.05.035","article-title":"The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices","volume":"57","author":"Levitan","year":"2011","journal-title":"Ann Emerg Med"},{"key":"R13-20250920","first-page":"1197","article-title":"Preoperative airway assessment: Predictive value of a multivariate risk index","volume":"82","author":"el-Ganzouri","year":"1996","journal-title":"Anesth Analg"},{"key":"R14-20250920","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1093\/bja\/aem297","article-title":"Predictive value of the El-Ganzouri multivariate risk index for difficult tracheal intubation: A comparison of GlideScope videolaryngoscopy and conventional Macintosh laryngoscopy","volume":"99","author":"Cortellazzi","year":"2007","journal-title":"Br J Anaesth"},{"key":"R15-20250920","first-page":"1011","article-title":"A new difficult airway management algorithm based upon the El Ganzouri risk index and GlideScope\u00ae videolaryngoscope: A new look for intubation?","volume":"77","author":"Caldiroli","year":"2011","journal-title":"Minerva Anestesiol"},{"key":"R16-20250920","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1213\/ane.0b013e31816d15c9","article-title":"A comparison of GlideScope videolaryngoscopy to direct laryngoscopy for nasotracheal intubation","volume":"107","author":"Jones","year":"2008","journal-title":"Anesth Analg"},{"key":"R17-20250920","first-page":"1318","article-title":"Nasotracheal intubation using GlideScope videolaryngoscope or Macintosh laryngoscope by novice laryngoscopists","volume":"59","author":"Shimada","year":"2010","journal-title":"Masui"},{"key":"R18-20250920","first-page":"201","article-title":"GlideScope versus direct laryngoscope for nasotracheal intubation in oral and maxillofacial surgery patients with anticipated difficult airways","volume":"5","author":"Ahmed","year":"2012","journal-title":"Ain Shams J Anesthesiol"},{"key":"R19-20250920","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/ANA.0b013e31829a0491","article-title":"A comparison of the GlideScope with the Macintosh laryngoscope for nasotracheal intubation in patients with ankylosing spondylitis","volume":"26","author":"Lili","year":"2014","journal-title":"J Neurosurg Anesthesiol"},{"key":"R20-20250920","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/1471-2253-11-6","article-title":"A randomised, controlled crossover comparison of the C-MAC videolaryngoscope with direct laryngoscopy in 150 patients during routine induction of anaesthesia","volume":"11","author":"Cavus","year":"2011","journal-title":"BMC Anesthesiol"},{"key":"R21-20250920","doi-asserted-by":"crossref","first-page":"182","DOI":"10.5152\/TJAR.2014.59672","article-title":"Comparison of the C-MAC D-Blade, conventional C-MAC, and Macintosh laryngoscopes in simulated easy and difficult airways","volume":"42","author":"Kili\u00e7aslan","year":"2014","journal-title":"Turk J Anaesthesiol Reanim"},{"key":"R22-20250920","first-page":"121","article-title":"Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: A randomized, controlled comparison in patients with suspected difficult airways","volume":"79","author":"Serocki","year":"2013","journal-title":"Minerva Anestesiol"},{"key":"R23-20250920","doi-asserted-by":"crossref","first-page":"376","DOI":"10.4103\/1658-354X.87266","article-title":"Use of Airtraq, C-Mac and GlideScope laryngoscope is better than Macintosh in novice medical students\u2019 hands: A manikin study","volume":"5","author":"Abdullah","year":"2011","journal-title":"Saudi J Anaesth"}],"container-title":["Saudi Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01437113-201812010-00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:52:33Z","timestamp":1787838753000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01437113-201812010-00007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.4103\/sja.sja_239_17","relation":{},"ISSN":["1658-354X","0975-3125"],"issn-type":[{"value":"1658-354X","type":"print"},{"value":"0975-3125","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,1]]}}}