{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T23:39:34Z","timestamp":1793144374211,"version":"4.5.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The pneumoperitoneum in laparoscopic surgeries elevates intracranial ICP because of the increased abdominal pressure, and ICP increases even further in the Trendelenburg position. A new noninvasive method to measure optic nerve sheath diameter (ONSD) via ultrasonography detects the raised ICP is reliable and inexpensive and can be repeated many times.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective observational study, 23 pediatric patients aged between 5 and 16 years, undergoing elective laparoscopic procedures under general anesthesia, were included. After endotracheal intubation with proper aseptic precautions, ocular ultrasound was performed to measure baseline ONSD in both eyes. Later, pneumoperitoneum was established by maintaining the intra-abdominal pressure (IAP) at 12 cmH2O. Again, ONSD was estimated at 15 minutes of pneumoperitoneum and observed for any variation from the previous readings. The cutoff considered for ONSD was 5 mm, above which the intracranial pressure (ICP) was regarded as increased.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      In our study, the mean age of subjects was 9.67 \u00b1 5.18 years. The majority were males (60.9%). The subjects showed an increase in ONSD at the 15\n                      <jats:sup>th<\/jats:sup>\n                      minute after inducing pneumoperitoneum using abdominal CO\n                      <jats:sub>2<\/jats:sub>\n                      insufflation, in comparison with the baseline values, in the left eye [4.67 \u00b1 0.48, P 0.016] and the right eye [4.63 \u00b1 0.43]. The readings of ONSD were observed to be &lt;5 mm, not statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>USG-guided ONSD measurements serve as a valuable tool in ensuring optimal intra-abdominal pressures and safe administration of anesthesia for patients undergoing laparoscopic surgery, particularly those vulnerable to an increase in ICP.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/sja.sja_408_24","type":"journal-article","created":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T01:54:04Z","timestamp":1735696444000},"page":"34-38","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Impact of laparoscopic surgeries on optic nerve sheath diameter (ONSD) in children"],"prefix":"10.4103","volume":"19","author":[{"given":"Mohsina","family":"Yasmeen","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Bangalore Medical College and Research Institute, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sumaiya","family":"Sabreen","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Bangalore Medical College and Research Institute, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akshay","family":"Bettanayaka","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Bangalore Medical College and Research Institute, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saraswathi","family":"Nagappa","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Bangalore Medical College and Research Institute, Bengaluru, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,1,1]]},"reference":[{"key":"R1-20260423","first-page":"481","article-title":"Comparison of effects of extubation in prone and supine positions in patients operated for lumbar disk herniation","volume":"32","author":"Gunenc","year":"2022","journal-title":"Turk Neurosurg"},{"key":"R2-20260423","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/ALN.0b013e3181c294e1","article-title":"Effects of prone and reverse Trendelenburg positioning on ocular parameters","volume":"112","author":"Grant","year":"2010","journal-title":"J Am Soc Anesthesiol"},{"key":"R3-20260423","doi-asserted-by":"crossref","first-page":"e111916.","DOI":"10.1371\/journal.pone.0111916","article-title":"Optic nerve sheath diameter remains constant during robot-assisted laparoscopic radical prostatectomy","volume":"9","author":"Verdonck","year":"2014","journal-title":"PLoS One"},{"key":"R4-20260423","first-page":"777","article-title":"Validation of optic nerve sheath response to changing cerebrospinal fluid pressure: Ultrasound findings during intrathecal infusion tests","volume":"87","author":"Hansen","year":"1997","journal-title":"J Nerosurg"},{"key":"R5-20260423","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1007\/s12028-009-9250-8","article-title":"Reliability of optic nerve ultrasound for the evaluation of patients with spontaneous intracranial hemorrhage","volume":"11","author":"Moretti","year":"2009","journal-title":"Nerocrit Care"},{"key":"R6-20260423","first-page":"342","article-title":"Intra and interobserver reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults","volume":"20","author":"Bauerle","year":"2010","journal-title":"J Neuroimaging"},{"key":"R7-20260423","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.annemergmed.2006.06.040","article-title":"Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased ICP in adult head injury patients","volume":"49","author":"Tyal","year":"2007","journal-title":"Ann Emerg Med"},{"key":"R8-20260423","doi-asserted-by":"crossref","first-page":"1075","DOI":"10.1007\/s00417-011-1878-3","article-title":"Intraocular pressure correlates with optic nerve sheath diameter in patients with normal tension glaucoma","volume":"250","author":"Abegao Pinto","year":"2012","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R9-20260423","first-page":"351","article-title":"The evolution of laparoscopy and the revolution in surgery in the decade of the 1990s","volume":"12","author":"Kelley","year":"2008","journal-title":"JSLS"},{"key":"R10-20260423","first-page":"1304","article-title":"IV Clonidine premedication in laparoscopic surgery","volume":"4","author":"Desai","year":"2016","journal-title":"JMSCR"},{"key":"R11-20260423","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1111\/j.1399-6576.2011.02432.x","article-title":"Ultrasonography of the optic nerve in neurocritically ill patients","volume":"55","author":"Moretti","year":"2011","journal-title":"Acta Anaesthesiol Scand"},{"key":"R12-20260423","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: A systematic review and meta-analysis","volume":"37","author":"Dubourg","year":"2011","journal-title":"Intensive Care Med"},{"key":"R13-20260423","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1007\/s12028-011-9606-8","article-title":"Optic nerve ultrasound for the detection of raised intracranial pressure","volume":"15","author":"Rajajee","year":"2011","journal-title":"Neurocrit Care"},{"key":"R14-20260423","doi-asserted-by":"crossref","first-page":"2062","DOI":"10.1007\/s00134-008-1149-x","article-title":"Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients","volume":"34","author":"Geeraerts","year":"2008","journal-title":"Intensive Care Med"},{"key":"R15-20260423","doi-asserted-by":"crossref","first-page":"1704","DOI":"10.1007\/s00134-007-0797-6","article-title":"Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury","volume":"33","author":"Geeraerts","year":"2007","journal-title":"Intensive Care Med"},{"key":"R16-20260423","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/j.annemergmed.2006.06.040","article-title":"Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients","volume":"49","author":"Tayal","year":"2007","journal-title":"Ann Emerg Med"},{"key":"R17-20260423","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.cnc.2015.10.005","article-title":"Optic nerve sheath diameter ultrasound and the diagnosis of increased intracranial pressure","volume":"28","author":"Hylkema","year":"2016","journal-title":"Crit Care Nurs Clin North Am"},{"key":"R18-20260423","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.jcjd.2015.07.007","article-title":"Optic nerve sheath diameter ultrasonography in pediatric with diabetic ketoacidosis","volume":"40","author":"Hansen","year":"2016","journal-title":"Can J Diabetes"},{"key":"R19-20260423","doi-asserted-by":"crossref","first-page":"2275","DOI":"10.1007\/s00381-013-2172-y","article-title":"Bedside optic nerve sheath diameter ultrasound for the evaluation of suspected pediatric ventriculoperitoneal shunt failure in the emergency department","volume":"29","author":"Hall","year":"2013","journal-title":"Childs Nerv Syst"},{"key":"R20-20260423","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s00381-008-0713-6","article-title":"Optic nerve sheath ultrasound in the assessment of paediatric hydrocephalus","volume":"25","author":"McAuley","year":"2009","journal-title":"Childs Nerv Syst"},{"key":"R21-20260423","doi-asserted-by":"crossref","first-page":"448e","DOI":"10.1097\/PRS.0b013e31825dc1f1","article-title":"Nocturnal ultrasound measurements of optic nerve sheath diameter correlate with intracranial pressure in children with craniosynostosis","volume":"130","author":"Driessen","year":"2012","journal-title":"Plast Reconstr Surg"},{"key":"R22-20260423","doi-asserted-by":"crossref","first-page":"e2018.00080.","DOI":"10.4293\/JSLS.2018.00080","article-title":"Abdominal compliance and laparoscopy: A review","volume":"23","author":"Ott","year":"2019","journal-title":"JSLS"},{"key":"R23-20260423","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.3906\/sag-2009-2","article-title":"The assessment of the effect of different intraabdominal pressures used for laparoscopic cholecystectomy surgery on optic nerve sheath diameter: A prospective observational cohort study","volume":"51","author":"Ert\u00fcrk","year":"2021","journal-title":"Turk J Med Sci"},{"key":"R24-20260423","doi-asserted-by":"crossref","first-page":"774","DOI":"10.5455\/medscience.2020.09.9226","article-title":"The effect of lower intra-abdominal pressure on intracranial pressure measured by optic nerve sheath diameter during laparoscopic surgery","volume":"9","author":"Kara","year":"2020","journal-title":"Med Sci"}],"container-title":["Saudi Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/sja.sja_408_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:37:54Z","timestamp":1787067474000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/sja.sja_408_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/sja.sja_408_24","relation":{},"ISSN":["1658-354X","0975-3125"],"issn-type":[{"value":"1658-354X","type":"print"},{"value":"0975-3125","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"2024-07-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-07-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}