{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T17:23:21Z","timestamp":1787765001033,"version":"build-2784847793"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To evaluate the corneal topography and aberrometry and their changes following ptosis surgery in patients suffering from unilateral congenital blepharoptosis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      The study included 15 eyes of 15 patients with unilateral congenital blepharoptosis who underwent surgical correction through anterior levator resection. Shack-Hartmann wavefront sensor was employed to assess Zernike coefficients and root-mean-square. Computerized corneal topography, Orbscan and aberrometry were measured pre-and 3 months post-surgery in the healthy and ptotic eyes. Aberrometric changes were compared between patients with more than one diopter of astigmatism and subjects with less amount of astigmatism. Data were analyzed using the SPSS version 16.\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05 was considered as significance level.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Following anterior levator resection, the amount of astigmatism decreased. However, the difference was not statistically significant. Changes in topographic indices were not statistically significant. Regarding tomographic indices, the change in minimum keratometry was significant. The amount of change in total higher-order aberrations (HOAs) was not statistically significant. However, there was a decrease in the amount of third-order aberrations (vertical coma and vertical trefoil) which was statistically significant for vertical coma (\u22120.002 \u00b1 0.001 vs. \u22120.08 \u00b1 0.02 \u00b5m,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.02). Comparing aberrometric changes in patients with more than 1 diopter astigmatism and less, there was a significant difference in the amount of HOA w\/o Z400.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Surgical correction of ptosis could reduce the ocular aberrations, despite no significant change in astigmatism. Nonaxial high-order aberrations are mostly affected probably due to the meridional effect of ptosis on the cornea.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/sjopt.sjopt_220_22","type":"journal-article","created":{"date-parts":[[2023,12,10]],"date-time":"2023-12-10T23:15:57Z","timestamp":1702250157000},"page":"233-236","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["The effect of ptosis surgery on corneal topography and aberrometry"],"prefix":"10.4103","volume":"37","author":[{"given":"Mohammad","family":"Sharifi","sequence":"first","affiliation":[{"name":"Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Acieh","family":"Es\u2019haghi","sequence":"additional","affiliation":[{"name":"Eye Research Center, The Five Senses Health Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad Y.","family":"Kiarudi","sequence":"additional","affiliation":[{"name":"Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,7,24]]},"reference":[{"key":"R1-20240830","doi-asserted-by":"crossref","first-page":"453","DOI":"10.2147\/OPTH.S111118","article-title":"Clinical presentation and management of congenital ptosis","volume":"11","author":"Marenco","year":"2017","journal-title":"Clin Ophthalmol"},{"key":"R2-20240830","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1055\/s-0037-1598631","article-title":"Pediatric blepharoptosis","volume":"31","author":"Jubbal","year":"2017","journal-title":"Semin Plast Surg"},{"key":"R3-20240830","doi-asserted-by":"crossref","first-page":"2468","DOI":"10.1038\/s41433-021-01547-5","article-title":"A review of acquired blepharoptosis: Prevalence, diagnosis, and current treatment options","volume":"35","author":"Bacharach","year":"2021","journal-title":"Eye (Lond)"},{"key":"R4-20240830","first-page":"86","article-title":"Effect of unilateral congenital ptosis on ocular higher order aberrations in children","volume":"2","author":"Ashok Kumar","year":"2013","journal-title":"Med Hypothesis Discov Innov Ophthalmol"},{"key":"R5-20240830","first-page":"334","article-title":"Amblyopia in congenital ptosis","volume":"26","author":"Hornblass","year":"1995","journal-title":"Ophthalmic Surg"},{"key":"R6-20240830","first-page":"345","article-title":"Amblyopia, refractive errors and strabismus in congenital ptosis","volume":"93","author":"St\u00e4rk","year":"1996","journal-title":"Ophthalmologe"},{"issue":"Pt 4","key":"R7-20240830","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1038\/eye.1999.136","article-title":"Corneal topography in patients with congenital ptosis","volume":"13","author":"U\u011furba\u015f","year":"1999","journal-title":"Eye (Lond)"},{"key":"R8-20240830","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1111\/j.1442-9071.1995.tb00181.x","article-title":"Congenital ptosis: Results of surgical management","volume":"23","author":"Whitehouse","year":"1995","journal-title":"Aust N Z J Ophthalmol"},{"key":"R9-20240830","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1016\/j.survophthal.2014.01.005","article-title":"Congenital ptosis","volume":"59","author":"SooHoo","year":"2014","journal-title":"Surv Ophthalmol"},{"key":"R10-20240830","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1007\/s00266-003-0127-5","article-title":"Ptosis: Causes, presentation, and management","volume":"27","author":"Finsterer","year":"2003","journal-title":"Aesthetic Plast Surg"},{"key":"R11-20240830","first-page":"1","article-title":"Astigmatic changes following ptosis correction surgery in 30 consecutive children seen in a regional institute of ophthalmology","volume":"8","author":"Agrawal","year":"2016","journal-title":"Int J Curr Res Rev"},{"key":"R12-20240830","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1067\/mpa.2001.118215","article-title":"Change in refractive error after unilateral levator resection for congenital ptosis","volume":"5","author":"Klimek","year":"2001","journal-title":"J AAPOS"},{"key":"R13-20240830","doi-asserted-by":"crossref","first-page":"85","DOI":"10.3928\/0191-3913-19920301-06","article-title":"Changes in astigmatism after surgery for congenital ptosis","volume":"29","author":"Cadera","year":"1992","journal-title":"J Pediatr Ophthalmol Strabismus"},{"key":"R14-20240830","first-page":"689","article-title":"Astigmatic change following congenital ptosis surgery","volume":"61","author":"Kao","year":"1998","journal-title":"Zhonghua Yi Xue Za Zhi (Taipei)"},{"key":"R15-20240830","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/00002341-199805000-00001","article-title":"Changes in astigmatism after ptosis surgery measured by corneal topography","volume":"14","author":"Holck","year":"1998","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"R16-20240830","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1097\/ICO.0000000000000729","article-title":"Corneal topographic changes after eyelid ptosis surgery","volume":"35","author":"Savino","year":"2016","journal-title":"Cornea"},{"key":"R17-20240830","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.4103\/ijo.IJO_2650_20","article-title":"Effect of congenital ptosis correction on corneal topography \u2013 A prospective study","volume":"69","author":"Assadi","year":"2021","journal-title":"Indian J Ophthalmol"},{"key":"R18-20240830","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1097\/ICO.0000000000002429","article-title":"Assessment of Long-term anterior and posterior topographic changes in the cornea after ptosis surgery using Fourier harmonic analysis","volume":"40","author":"Yamamoto","year":"2021","journal-title":"Cornea"},{"key":"R19-20240830","doi-asserted-by":"crossref","first-page":"203","DOI":"10.3928\/1081-597X-20040501-03","article-title":"Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia","volume":"20","author":"Llorente","year":"2004","journal-title":"J Refract Surg"},{"key":"R20-20240830","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1167\/iovs.09-4090","article-title":"Eyelid pressure and contact with the ocular surface","volume":"51","author":"Shaw","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Saudi Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/sjopt.sjopt_220_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:53:15Z","timestamp":1787763195000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/sjopt.sjopt_220_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/sjopt.sjopt_220_22","relation":{},"ISSN":["1319-4534","2542-6680"],"issn-type":[{"value":"1319-4534","type":"print"},{"value":"2542-6680","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7]]},"assertion":[{"value":"2022-12-17","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}