{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:32:00Z","timestamp":1787776320820,"version":"build-2784847793"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T00:00:00Z","timestamp":1747958400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract:<\/jats:title>\n                  <jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To evaluate the feasibility of virtual oculoplastic surgery using digital three-dimensional (3D) camera-based virtual-reality surgical magnification loupes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>A commercially available 3D video camera was used as an overhead binocular digital magnifying loupe, which projects a real-time 3D stereo image of the surgical field to a virtual-reality glasses worn by the surgeon and simultaneously records the surgical field. The surgeon used the digital binocular virtual surgical loupes (DBVSL) as the main source of visualization and magnification. The surgeon estimated the percentage of time he used the DBVSL as the sole method of visualization. The surgery was considered mainly performed using the DBVSL if it was estimated to be used for more than 50% of the procedure duration.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      A total of 15 oculoplastic surgical procedures were attempted by three oculoplastic surgeons using the described digital binocular surgical loupes. Surgical procedures included chalazion incision and curettage (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 4), eyelid mass excision with the closure of the wound by sutures (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 6), frontalis sling (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 2), levator tucking (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 1), external dacryocystorhinostomy (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 1), and eyelid splitting and anterior lamellar excision (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 1). Fourteen out of 15 procedures could be successfully performed using the described DBVSL as the main method of visualization and magnification. Only the external DCR could not be mainly performed using the virtual surgical loupe.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>DBVSL is a promising asset in oculoplastic surgery to provide sufficient surgical field magnification and surgical recording with the surgeon operating in a comfortable normally extended neck and back position. Further enhancements are required to improve the depth of focus, the stereoscopic depth clues and the ergonomics to make DBVSL versatile to different oculoplastic procedures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/sjopt.sjopt_62_25","type":"journal-article","created":{"date-parts":[[2025,5,24]],"date-time":"2025-05-24T03:04:18Z","timestamp":1748055858000},"page":"217-220","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Digital binocular surgical loupes for oculoplastic surgery using a three-dimensional digital camera and a virtual reality smart glasses: A pilot study"],"prefix":"10.4103","volume":"39","author":[{"given":"Omar","family":"Solyman","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Harvey and Bernice Jones Eye Institute, University of Arkansas for Medical Sciences, Little Rock, AR, USA"},{"name":"Department of Ophthalmology, Qassim University Medical City, Buraydah, Al-Qassim, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed M.","family":"Alaraj","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, College of Medicine, Qassim University, Buraydah, Al-Qassim, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed A.","family":"Youssef","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John D.","family":"Pemberton","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Harvey and Bernice Jones Eye Institute, University of Arkansas for Medical Sciences, Little Rock, AR, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kareem B.","family":"Elessawy","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Faculty of Medicine, Cairo University, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,5,23]]},"reference":[{"key":"R1-20251014","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.ajo.2004.06.091","article-title":"Symptoms of musculoskeletal disorders in ophthalmologists","volume":"139","author":"Dhimitri","year":"2005","journal-title":"Am J Ophthalmol"},{"key":"R2-20251014","doi-asserted-by":"crossref","first-page":"1555","DOI":"10.1097\/PRS.0b013e3181d62a94","article-title":"Occupational injury in plastic surgeons","volume":"125","author":"Capone","year":"2010","journal-title":"Plast Reconstr Surg"},{"key":"R3-20251014","doi-asserted-by":"crossref","first-page":"730","DOI":"10.5435\/JAAOS-D-19-00834","article-title":"Occupation-related cervical spine disease in orthopaedic surgeons","volume":"28","author":"Wyatt","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"key":"R4-20251014","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1016\/S0090-4295(00)00488-X","article-title":"Survey of neuromuscular injuries to the patient and surgeon during urologic laparoscopic surgery","volume":"55","author":"Wolf","year":"2000","journal-title":"Urology"},{"key":"R5-20251014","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1471-2474-5-16","article-title":"Prevalence of musculoskeletal disorders in dentists","volume":"5","author":"Alexopoulos","year":"2004","journal-title":"BMC Musculoskelet Disord"},{"key":"R6-20251014","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1177\/21925682221148685","article-title":"Epidemiology of Work-Related Neck Pain Among Spine Surgeons","volume":"14","author":"Abolfotouh","year":"2024","journal-title":"Global Spine J"},{"key":"R7-20251014","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/IOP.0b013e3181e99cc8","article-title":"A survey study of occupational pain and injury in ophthalmic plastic surgeons","volume":"27","author":"Sivak-Callcott","year":"2011","journal-title":"Ophthalmic Plast Reconstr Surg"},{"key":"R8-20251014","doi-asserted-by":"crossref","first-page":"e3196","DOI":"10.1097\/GOX.0000000000003196","article-title":"No longer a pain in the neck:Use of operating microscope for palatoplasty","volume":"8","author":"Tanaka","year":"2020","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R9-20251014","doi-asserted-by":"crossref","first-page":"e101","DOI":"10.1111\/aos.14518","article-title":"Clinical experience of using the NGENUITY three-dimensional surgery system in ophthalmic surgical procedures","volume":"99","author":"Liu","year":"2021","journal-title":"Acta Ophthalmol"},{"key":"R10-20251014","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.jcjo.2017.08.011","article-title":"Surgical loupe usage among oculoplastic surgeons in North America","volume":"53","author":"Wei","year":"2018","journal-title":"Can J Ophthalmol"},{"key":"R11-20251014","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1097\/IOP.0000000000001163","article-title":"Three-dimensional surgery in oculoplastics","volume":"34","author":"Garrido-Hermosilla","year":"2018","journal-title":"Ophthalmic Plast Reconstr Surg"}],"container-title":["Saudi Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/sjopt.sjopt_62_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:05:48Z","timestamp":1787774748000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/sjopt.sjopt_62_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,23]]},"references-count":11,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/sjopt.sjopt_62_25","relation":{},"ISSN":["1319-4534","2542-6680"],"issn-type":[{"value":"1319-4534","type":"print"},{"value":"2542-6680","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,23]]},"assertion":[{"value":"2025-02-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-04-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}