{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:19:47Z","timestamp":1787840387297,"version":"build-2784847793"},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2024,11,8]],"date-time":"2024-11-08T00:00:00Z","timestamp":1731024000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract:<\/jats:title>\n                  <jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>Optic disc size measurement is essential for determining landmarks, lesions, and distances of the retina. Due to the size variability in nature and when measured with different instruments, newer methods to compare sizes between different instruments are needed. We aimed to determine the comparability of slit lamp, fundus photography, and optical coherence tomography (OCT) measurements of optic disc size after correcting for both ocular and instrument magnification.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>MATERIALS AND METHODS:<\/jats:title>\n                    <jats:p>In this prospective, observational study, optic disc size was measured by slit-lamp biomicroscopy, fundus photography, and OCT. Instrument and ocular magnification was calculated, and the measured size was corrected for both using the Littman formula. The corrected values were analyzed using Bland\u2013Altman plots and intra-class correlation (ICC) for agreeability and correlation, respectively. Linear regression analysis was conducted to estimate the systematic errors and interconvertibility in cases of high correlation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Fifty-six eyes were included for the analysis. Uncorrected and corrected values for each method had excellent correlation and agreeability (ICC absolute agreement &gt;0.75,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01). Among magnification corrected values, slit lamp and OCT had excellent correlation and agreement (ICC consistency = 0.846, confidence interval 0.75\u20130.91,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01). This pair had\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.73 on linear regression (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01). Linear regression formulas for interconverting uncorrected and corrected values for the three methods had variable accuracy (\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      from 0.47 to 0.66).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Uncorrected values of different methods for disc size measurement cannot be compared directly; they need ocular and instrument magnification correction. Among the three methods compared, the best interconvertible pairs of measurement were magnification corrected slit lamp and OCT values.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/tjo.tjo-d-24-00058","type":"journal-article","created":{"date-parts":[[2024,11,9]],"date-time":"2024-11-09T01:00:10Z","timestamp":1731114010000},"page":"466-473","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of magnification corrected optic disc size by slit-lamp biomicroscopy, fundus photography, and optical coherence tomography"],"prefix":"10.4103","volume":"15","author":[{"given":"Linya","family":"Thomas","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chidanand","family":"Kulkarni","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Neetha I. R.","family":"Kuzhuppilly","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kasturba Medical College Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,11,8]]},"reference":[{"key":"R1-20250915","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1136\/bjo.2003.028548","article-title":"The effect of optic disc diameter on vertical cup to disc ratio percentiles in a population based cohort: The Blue Mountains eye study","volume":"88","author":"Crowston","year":"2004","journal-title":"Br J Ophthalmol"},{"key":"R2-20250915","first-page":"1764","article-title":"Ranking of optic disc variables for detection of glaucomatous optic nerve damage","volume":"41","author":"Jonas","year":"2000","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R3-20250915","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1016\/S0002-9394(02)02093-7","article-title":"Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy","volume":"135","author":"Schuman","year":"2003","journal-title":"Am J Ophthalmol"},{"key":"R4-20250915","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.survophthal.2006.10.002","article-title":"Optic disk size and glaucoma","volume":"52","author":"Hoffmann","year":"2007","journal-title":"Surv Ophthalmol"},{"key":"R5-20250915","doi-asserted-by":"crossref","first-page":"e193","DOI":"10.1111\/j.1755-3768.2010.01923.x","article-title":"Heritability of optic disc diameters: A twin study","volume":"89","author":"Drobnjak","year":"2011","journal-title":"Acta Ophthalmol"},{"key":"R6-20250915","doi-asserted-by":"crossref","first-page":"4475","DOI":"10.1167\/iovs.12-9682","article-title":"The effects of peripapillary atrophy on the diagnostic ability of stratus and cirrus OCT in the analysis of optic nerve head parameters and disc size","volume":"53","author":"Kim","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R7-20250915","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1046\/j.1475-1313.2001.00551.x","article-title":"How large is the optic disc? Systematic errors in fundus cameras and topographers","volume":"21","author":"Meyer","year":"2001","journal-title":"Ophthalmic Physiol Opt"},{"key":"R8-20250915","first-page":"2576","article-title":"Possible errors in the measurement of retinal lesions","volume":"34","author":"Arnold","year":"1993","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R9-20250915","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1055\/s-2008-1055068","article-title":"Zur Bestimmung der wahren Gr\u00f6sse eines Objektes auf dem Hintergrund des lebenden Auges [Determination of the real size of an object on the fundus of the living eye","volume":"180","author":"Littmann","year":"1982","journal-title":"Klin Monbl Augenheilkd"},{"key":"R10-20250915","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1007\/BF00175988","article-title":"Improvements on littmann's method of determining the size of retinal features by fundus photography","volume":"232","author":"Bennett","year":"1994","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"R11-20250915","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1136\/bjo.82.6.643","article-title":"Measurement of optic disc size: Equivalence of methods to correct for ocular magnification","volume":"82","author":"Garway-Heath","year":"1998","journal-title":"Br J Ophthalmol"},{"key":"R12-20250915","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1111\/j.1475-1313.2005.00339.x","article-title":"Comparison of optical coherence tomography and fundus photography for measuring the optic disc size","volume":"26","author":"Neubauer","year":"2006","journal-title":"Ophthalmic Physiol Opt"},{"key":"R13-20250915","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1055\/s-2008-1035137","article-title":"Ophthalmoscopic assessment of the size of the optic nerve papilla","volume":"211","author":"Papastathopoulos","year":"1997","journal-title":"Klin Monbl Augenheilkd"},{"key":"R14-20250915","doi-asserted-by":"crossref","first-page":"361","DOI":"10.4103\/0301-4738.55075","article-title":"Clinical measurement and categorization of optic disc in glaucoma patients","volume":"57","author":"Rao","year":"2009","journal-title":"Indian J Ophthalmol"},{"key":"R15-20250915","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1016\/j.ophtha.2010.12.008","article-title":"Comparison of automated analysis of Cirrus HD OCT spectral-domain optical coherence tomography with stereo photographs of the optic disc","volume":"118","author":"Sharma","year":"2011","journal-title":"Ophthalmology"},{"key":"R16-20250915","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1097\/00006324-200306000-00012","article-title":"Vertical cup-to-disc ratio: Agreement between direct ophthalmoscopic estimation, fundus biomicroscopic estimation, and scanning laser ophthalmoscopic measurement","volume":"80","author":"Watkins","year":"2003","journal-title":"Optom Vis Sci"},{"key":"R17-20250915","doi-asserted-by":"crossref","first-page":"4075","DOI":"10.1167\/iovs.09-4737","article-title":"Effect of myopia on the thickness of the retinal nerve fiber layer measured by Cirrus HD optical coherence tomography","volume":"51","author":"Kang","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R18-20250915","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1111\/opo.12009","article-title":"Statistical guidelines for the analysis of data obtained from one or both eyes","volume":"33","author":"Armstrong","year":"2013","journal-title":"Ophthalmic Physiol Opt"},{"key":"R19-20250915","doi-asserted-by":"crossref","first-page":"1570","DOI":"10.1001\/archopht.123.11.1570","article-title":"Asimplified severity scale for age-related macular degeneration: AREDS report no","volume":"123","author":"Ferris","year":"2005","journal-title":"18. Arch Ophthalmol"},{"key":"R20-20250915","first-page":"1817","article-title":"Magnification characteristic of a+90-diopter double-aspheric fundus examination lens","volume":"43","author":"Ansari-Shahrezaei","year":"2002","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R21-20250915","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"Koo","year":"2016","journal-title":"J Chiropr Med"},{"key":"R22-20250915","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: Uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol Bull"},{"key":"R23-20250915","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1136\/bjo.2010.196782","article-title":"The influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT","volume":"96","author":"Savini","year":"2012","journal-title":"Br J Ophthalmol"},{"key":"R24-20250915","doi-asserted-by":"crossref","first-page":"427","DOI":"10.4103\/0301-4738.159877","article-title":"Effect of ocular magnification on macular measurements made using spectral domain optical coherence tomography","volume":"63","author":"Parthasarathy","year":"2015","journal-title":"Indian J Ophthalmol"},{"key":"R25-20250915","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1111\/cxo.12052","article-title":"Retinal nerve fibre layer thickness and optic nerve head size measured in high myopes by optical coherence tomography","volume":"96","author":"Hsu","year":"2013","journal-title":"Clin Exp Optom"},{"key":"R26-20250915","doi-asserted-by":"crossref","first-page":"135","DOI":"10.4103\/ojo.OJO_234_2016","article-title":"Choroidal melanoma: A short review with an Indian perspective","volume":"10","author":"Pal","year":"2017","journal-title":"Oman J Ophthalmol"},{"key":"R27-20250915","doi-asserted-by":"crossref","first-page":"e0238072","DOI":"10.1371\/journal.pone.0238072","article-title":"Sensitivity and specificity of high-resolution wide field fundus imaging for detecting neovascular age-related macular degeneration","volume":"15","author":"Maruyama-Inoue","year":"2020","journal-title":"PLoS One"},{"key":"R28-20250915","doi-asserted-by":"crossref","first-page":"974","DOI":"10.1136\/bjophthalmol-2019-314706","article-title":"Comparison of a commercial spectral-domain OCT and swept-source OCT based on an angiography scan for measuring circumpapillary retinal nerve fibre layer thickness","volume":"104","author":"Tan","year":"2020","journal-title":"Br J Ophthalmol"},{"key":"R29-20250915","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1016\/S0161-6420(88)33177-5","article-title":"Intraobserver and interobserver agreement in measurement of optic disc characteristics","volume":"95","author":"Tielsch","year":"1988","journal-title":"Ophthalmology"},{"key":"R30-20250915","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1136\/bjo.2004.046169","article-title":"Digital imaging of the optic nerve head: Monoscopic and stereoscopic analysis","volume":"89","author":"Morgan","year":"2005","journal-title":"Br J Ophthalmol"},{"key":"R31-20250915","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1097\/IJG.0b013e31818153da","article-title":"Comparison of quantitative imaging devices and subjective optic nerve head assessment by general ophthalmologists to differentiate normal from glaucomatous eyes","volume":"18","author":"Vessani","year":"2009","journal-title":"J Glaucoma"},{"key":"R32-20250915","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.ophtha.2009.09.026","article-title":"Clinical assessment of stereoscopic optic disc photographs for glaucoma: The European optic disc assessment trial","volume":"117","author":"Reus","year":"2010","journal-title":"Ophthalmology"},{"key":"R33-20250915","doi-asserted-by":"crossref","first-page":"990611","DOI":"10.3389\/fmed.2022.990611","article-title":"Stereoscopic versus. monoscopic photographs on optic disc evaluation and glaucoma diagnosis among general ophthalmologists: A cloud-based real-world multicenter study","volume":"9","author":"Yang","year":"2022","journal-title":"Front Med (Lausanne)"}],"container-title":["Taiwan Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/tjo.TJO-D-24-00058","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:21:52Z","timestamp":1787836912000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/tjo.TJO-D-24-00058"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,8]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/tjo.tjo-d-24-00058","relation":{},"ISSN":["2211-5056","2211-5072"],"issn-type":[{"value":"2211-5056","type":"print"},{"value":"2211-5072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,8]]},"assertion":[{"value":"2024-05-14","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-09-10","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}