{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:29:37Z","timestamp":1787758177308,"version":"build-2784847793"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>To study the visual outcomes and higher order aberrations in eyes implanted with Hybrid EDOF IOL, particularly in Indian eyes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>MATERIALS AND METHODS:<\/jats:title>\n                    <jats:p>This is retrospective case series where subjects aged between 40-65 years and were implanted with LUCIDIS IOL by single surgeon were included. Subjects with Pre surgery corneal astigmatism &gt; 1.50 D, corneal guttae, IOP &gt;22mmHg, any ocular Co morbidities, Intra or post operative complication were excluded. At 1 month follow up, uncorrected visual acuities at distance (UCDVA), intermediate (UCIVA) and near (UCNVA), refraction were recorded. Internal Higher order aberrations and strehl ratio for a fixed pupil of 4mm and 6mm were calculated using NIDEK OPD Scan. Monocular defocus curve was obtained at 4 meter logMAR chart.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>Total of 55 eyes of 35 patients with mean\u00b1SD age of 58.50\u00b17.49 years were evaluated. 89.09% of the eyes achieved visual acuity of 6\/6. 49.09% could read N10 font at intermediate distance without any correction and 85.45% of the eyes had uncorrected near visual acuity of N6. Around 67% of the eyes did not require any refractive correction whereas around 26% of the eyes required correction upto \u00b10.25D. The defocus curve showed that visual acuity also ranges from 0.05 logMAR to 0.2 logMAR for Plano to -3.00D respectively. Mean\u00b1SD Strehl ratio at 4 and 6 mm pupil size was 0.06\u00b10.04 and 0.02\u00b10.02 respectively.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Hybrid EDOF IOL such as LUCIDIS provides excellent vision at all distances. This could be attributed to IOL design which is spherical aberration neutral lens.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/tjo.tjo_16_22","type":"journal-article","created":{"date-parts":[[2022,8,22]],"date-time":"2022-08-22T03:22:44Z","timestamp":1661138564000},"page":"341-345","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens"],"prefix":"10.4103","volume":"13","author":[{"given":"Vaishal P.","family":"Kenia","sequence":"first","affiliation":[{"name":"Department of Cataract and Refractive Surgery, Kenia Eye Hospital, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raj V.","family":"Kenia","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kenia Foundation, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laxmi","family":"Mudaliya","sequence":"additional","affiliation":[{"name":"Department of Cataract and Refractive Surgery, Kenia Eye Hospital, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Onkar H.","family":"Pirdankar","sequence":"additional","affiliation":[{"name":"Department of Clinical Research, Kenia Medical and Research Foundation, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,8,22]]},"reference":[{"key":"R1-20240830","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1097\/00132578-200104000-00016","article-title":"Contrast sensitivity and glare disability after lens implantation","volume":"2","author":"Schmitz","year":"2001","journal-title":"Evid Based Eye Care"},{"key":"R2-20240830","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1186\/s12886-017-0462-y","article-title":"Short term visual outcomes of a new trifocal intraocular lens","volume":"17","author":"Garc\u00eda-P\u00e9rez","year":"2017","journal-title":"BMC Ophthalmol"},{"key":"R3-20240830","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1097\/APO.0000000000000296","article-title":"Extended depth-of-field intraocular lenses:An update","volume":"9","author":"Kanclerz","year":"2020","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"R4-20240830","doi-asserted-by":"crossref","first-page":"1625","DOI":"10.1016\/j.jcrs.2019.07.014","article-title":"Defocus curves of 4 presbyopia-correcting IOL designs:Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus","volume":"45","author":"B\u00f6hm","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R5-20240830","doi-asserted-by":"crossref","first-page":"9283021","DOI":"10.1155\/2020\/9283021","article-title":"Comparative analysis of visual performance and astigmatism tolerance with monofocal, bifocal, and extended depth-of-focus intraocular lenses targeting slight myopia","volume":"2020","author":"Xu","year":"2020","journal-title":"J Ophthalmol"},{"key":"R6-20240830","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1080\/02713683.2020.1833347","article-title":"A comparative evaluation of diffractive trifocal and new refractive\/extended depth of focus intraocular lenses for refractive lens exchange","volume":"46","author":"Ozulken","year":"2021","journal-title":"Curr Eye Res"},{"key":"R7-20240830","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1055\/a-0799-9700","article-title":"Visual performance, subjective satisfaction and quality of life effect of a new refractive intraocular lens with central extended depth of focus","volume":"236","author":"Gillmann","year":"2019","journal-title":"Klin Monbl Augenheilkd"},{"key":"R8-20240830","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.jcrs.2019.02.023","article-title":"Clinical and aberrometric evaluation of a new extended depth-of-focus intraocular lens based on spherical aberration","volume":"45","author":"Bellucci","year":"2019","journal-title":"J Cataract Refract Surg"},{"key":"R9-20240830","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.jcrs.2011.08.029","article-title":"Modulation transfer function and optical quality after bilateral implantation of a+3.00 D versus a+4.00 D multifocal intraocular lens","volume":"38","author":"Santhiago","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R10-20240830","doi-asserted-by":"crossref","first-page":"1413","DOI":"10.3349\/ymj.2014.55.5.1413","article-title":"Evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes","volume":"55","author":"Lee","year":"2014","journal-title":"Yonsei Med J"},{"key":"R11-20240830","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1186\/s12886-019-1162-6","article-title":"Objective optical quality in eyes with customized selection of aspheric intraocular lens implantation","volume":"19","author":"Tan","year":"2019","journal-title":"BMC Ophthalmol"},{"key":"R12-20240830","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/j.jcrs.2008.04.031","article-title":"Optimizing measurement of subjective amplitude of accommodation with defocus curves","volume":"34","author":"Gupta","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R13-20240830","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1038\/eye.2015.12","article-title":"Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology","volume":"29","author":"Ouchi","year":"2015","journal-title":"Eye (Lond)"},{"key":"R14-20240830","first-page":"1","article-title":"Extended depth of focus imaging:A review","volume":"1","author":"Zalevsky","year":"2010","journal-title":"SPIE Rev"},{"key":"R15-20240830","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1016\/j.jcrs.2007.12.038","article-title":"Optical performance of monofocal and multifocal intraocular lenses in the human eye","volume":"34","author":"Ortiz","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R16-20240830","doi-asserted-by":"crossref","first-page":"2048","DOI":"10.1016\/j.jcrs.2010.07.021","article-title":"Double-pass system analysis of the visual outcomes and optical performance of an apodized diffractive multifocal intraocular lens","volume":"36","author":"Moreno","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R17-20240830","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.jcrs.2011.08.034","article-title":"Visual function comparison of 2 aspheric multifocal intraocular lenses","volume":"38","author":"Alfonso","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R18-20240830","doi-asserted-by":"crossref","first-page":"S556","DOI":"10.3928\/1081-597X-20020901-12","article-title":"Are all aberrations equal?","volume":"18","author":"Applegate","year":"2002","journal-title":"J Refract Surg"},{"key":"R19-20240830","first-page":"8","article-title":"Clinical and aberrometric evaluation of a new refractive intraocular lens with central extended depth-of-focus (Lucidis\u00a9)","volume":"1","author":"Aref","year":"2019","journal-title":"J Clin Ophthalmol Vis"},{"key":"R20-20240830","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12886-019-1204-0","article-title":"Efficacy and safety of extended depth of focus intraocular lenses in cataract surgery:A systematic review and meta-analysis","volume":"19","author":"Liu","year":"2019","journal-title":"BMC Ophthalmol"}],"container-title":["Taiwan Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/tjo.tjo_16_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:09:06Z","timestamp":1787756946000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/tjo.tjo_16_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,22]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/tjo.tjo_16_22","relation":{},"ISSN":["2211-5056","2211-5072"],"issn-type":[{"value":"2211-5056","type":"print"},{"value":"2211-5072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,22]]},"assertion":[{"value":"2021-12-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-02-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}