{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T20:28:04Z","timestamp":1786739284052,"version":"build-2736575974"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,10]]},"abstract":"<jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>\n                      To compare and evaluate improvement in corrected distant visual acuity (CDVA) between myopia and hyperopia after laser\n                      <jats:italic toggle=\"yes\">in situ<\/jats:italic>\n                      keratomileusis (LASIK) in adult patients with anisometropic amblyopia.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>MATERIALS AND METHODS:<\/jats:title>\n                    <jats:p>This prospective clinical study included 103 amblyopic eyes (103 patients), which underwent LASIK correction of refractive error from January 2013 to January 2018. Uncorrected distance visual acuity (UDVA), CDVA, spherical equivalent (SE), postoperative astigmatism, and intraocular pressure were evaluated at time points of 1, 6, and 12 months.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Patients were divided into two groups according to refractive error. Group 1: Forty-six patients with myopia and Group 2: Fifty-seven patients with hyperopia. Mean CDVA (logarithm of the minimum angle of resolution [logMAR]) preoperatively was 0.23 \u00b1 0.16 in Group 1 and 0.40 \u00b1 0.19 in Group 2. Postoperative CDVA (logMAR) was 0.17 \u00b1 0.13 in Group 1 and 0.32 \u00b1 0.17 in Group 2. There was statistically significant increase in UDVA (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.0001) postoperatively and no change during the follow-up period of 12 months in both groups. Group 1 showed more expectable results, 95% of variability SE achieved was dependent on SE intended (\n                      <jats:italic toggle=\"yes\">R2 =<\/jats:italic>\n                      0.95), while in Group 2, the percentage was slightly lower of expected 87% (\n                      <jats:italic toggle=\"yes\">R2 =<\/jats:italic>\n                      0.87). There was statistical significance in respect of CDVA change postoperatively and preoperatively in both groups. Correlation factors are low, in Group 1\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = \u22120.53 and in Group 2\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = \u22120.39.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>LASIK can improve CDVA in a considerable portion of amblyopic eyes, both myopic and hyperopic. Eyes with better initial CDVA and those with myopia were associated with greater improvement in postoperative CDVA.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/tjo.tjo_22_21","type":"journal-article","created":{"date-parts":[[2021,7,14]],"date-time":"2021-07-14T10:46:17Z","timestamp":1626259577000},"page":"452-456","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Laser keratomileusis in treatment of anisometropic amblyopia in adults"],"prefix":"10.4103","volume":"12","author":[{"given":"Pidro","family":"Ajla","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmedegovi\u0107-Pjano","family":"Melisa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mravi\u010di\u0107","family":"Ivana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gri\u0161evi\u0107","family":"Senad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bi\u0161\u010devi\u0107","family":"Alma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pidro","family":"Aida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-10-20240830","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1111\/j.1444-0938.2005.tb05102.x","article-title":"Amblyopia: Prevalence, natural history, functional effects and treatment","volume":"88","author":"Webber","year":"2005","journal-title":"Clin Exp Optom"},{"key":"R3-10-20240830","doi-asserted-by":"crossref","first-page":"123","DOI":"10.4103\/2090-0686.127344","article-title":"The visual outcome of anisometropic amblyopia after laser-assisted in-situ keratomileusis surgery","volume":"106","author":"El-Nahas","year":"2013","journal-title":"J Egypt Ophthalmol Soc"},{"key":"R4-10-20240830","first-page":"17","article-title":"LASIK for anisometropia results in good patient satisfaction","volume":"5","author":"Chan","year":"2001","journal-title":"Ocul Surg News Eur Asia Ed"},{"key":"R5-10-20240830","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1111\/j.1475-1313.2012.00939.x","article-title":"The differing impact of induced astigmatic blur on crowded and uncrowded paediatric visual acuity chart results","volume":"32","author":"Little","year":"2012","journal-title":"Ophthalmic Physiol Opt"},{"key":"R6-10-20240830","doi-asserted-by":"crossref","first-page":"2517","DOI":"10.1016\/j.jcrs.2004.06.026","article-title":"Improvement in best corrected visual acuity in amblyopic adult eyes after laser in situ keratomileusis","volume":"30","author":"Sakatani","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R7-10-20240830","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1177\/112067210601600204","article-title":"Visual outcome after excimer laser refractive surgery in adult patients with amblyopia","volume":"16","author":"Roszkowska","year":"2006","journal-title":"Eur J Ophthalmol"},{"key":"R8-10-20240830","doi-asserted-by":"crossref","first-page":"2167","DOI":"10.1016\/j.jcrs.2011.06.026","article-title":"Photorefractive keratectomy in treatment of refractive amblyopia in the adult population","volume":"37","author":"Cagil","year":"2011","journal-title":"J Cataract Refract Surg"},{"key":"R9-10-20240830","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1016\/j.jcrs.2016.12.029","article-title":"Visual outcomes of laser vision correction in eyes with preoperative amblyopia","volume":"43","author":"Sorkin","year":"2017","journal-title":"J Cataract Refract Surg"},{"key":"R10-10-20240830","doi-asserted-by":"crossref","first-page":"2654170","DOI":"10.1155\/2019\/2654170","article-title":"Threshold values of myopic anisometropia causing loss of stereopsis","volume":"2019","author":"Gaw\u0119cki","year":"2019","journal-title":"J Ophthalmol"},{"key":"R11-10-20240830","first-page":"1870","article-title":"Posterior chamber phakic intraocular lens for the correction of high myopic anisometropic amblyopia in adults","volume":"11","author":"Zhang","year":"2018","journal-title":"Int J Ophthalmol"},{"key":"R12-10-20240830","first-page":"362","article-title":"Laser in situ keratomileusis in adult patients with anisometropic amblyopia","volume":"6","author":"Agca","year":"2013","journal-title":"Int J Ophthalmol"},{"key":"R13-10-20240830","doi-asserted-by":"crossref","first-page":"264","DOI":"10.3928\/1081-597X-20000302-15","article-title":"Laser keratomileusis for anisometropic amblyopia","volume":"16","author":"Dedhia","year":"2000","journal-title":"J Refract Surg"},{"key":"R14-10-20240830","doi-asserted-by":"crossref","first-page":"25","DOI":"10.3928\/1081-597X-20040101-05","article-title":"Laser in situ keratomileusis improves visual acuity in some adult eyes with amblyopia","volume":"20","author":"Barequet","year":"2004","journal-title":"J Refract Surg"},{"key":"R15-10-20240830","doi-asserted-by":"crossref","first-page":"447","DOI":"10.3928\/1081-597X-20070501-05","article-title":"Improvement of visual acuity following refractive surgery for myopia and myopic anisometropia","volume":"23","author":"Vuori","year":"2007","journal-title":"J Refract Surg"},{"key":"R16-10-20240830","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1098\/rstb.2008.0203","article-title":"Improving the performance of the amblyopic visual system","volume":"364","author":"Levi","year":"2009","journal-title":"Philos Trans R Soc Lond B Biol Sci"},{"key":"R17-10-20240830","doi-asserted-by":"crossref","first-page":"674","DOI":"10.3928\/1081597X-20150928-06","article-title":"Three-year follow-up of hyperopic LASIK using a 500-Hz excimer laser system","volume":"31","author":"Plaza-Puche","year":"2015","journal-title":"J Refract Surg"},{"key":"R18-10-20240830","doi-asserted-by":"crossref","first-page":"548","DOI":"10.3928\/1081-597X-20030901-09","article-title":"Laser in situ keratomileusis for hyperopia and hyperopic and mixed astigmatism with LADARVision using 7 to 10-mm ablation diameters","volume":"19","author":"Carones","year":"2003","journal-title":"J Refract Surg"},{"key":"R19-10-20240830","doi-asserted-by":"crossref","first-page":"6830","DOI":"10.1073\/pnas.93.13.6830","article-title":"Neural plasticity in adults with amblyopia","volume":"93","author":"Levi","year":"1996","journal-title":"Proc Natl Acad Sci U S A"},{"key":"R20-10-20240830","first-page":"1493","article-title":"Improvement in Vernier acuity in adults with amblyopia. Practice makes better","volume":"38","author":"Levi","year":"1997","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R21-10-20240830","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/0042-6989(92)90021-A","article-title":"Rapid reorganization of cortical maps in adult cats following restricted deafferentation in retina","volume":"32","author":"Chino","year":"1992","journal-title":"Vision Res"},{"key":"R22-10-20240830","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1136\/bjo.84.9.952","article-title":"Amblyopia: Is visual loss permanent?","volume":"84","author":"El Mallah","year":"2000","journal-title":"Br J Ophthalmol"}],"container-title":["Taiwan Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/tjo.tjo_22_21","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:27:34Z","timestamp":1786735654000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/tjo.tjo_22_21"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/tjo.tjo_22_21","relation":{},"ISSN":["2211-5056"],"issn-type":[{"value":"2211-5056","type":"print"}],"subject":[],"published":{"date-parts":[[2022,10]]}}}