{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T10:50:10Z","timestamp":1777891810748,"version":"3.51.4"},"reference-count":19,"publisher":"SAGE Publications","issue":"7","license":[{"start":{"date-parts":[[2015,7,1]],"date-time":"2015-07-01T00:00:00Z","timestamp":1435708800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respir Care"],"published-print":{"date-parts":[[2015,7]]},"abstract":"<jats:p>The incidence of pneumothoraces with automated cardiopulmonary resuscitation (CPR) is unknown. Herein, we present 4 cases of pneumothoraces occurring in the setting of automated mechanical CPR (AM-CPR) in a 2-month period since incorporating mechanical devices into our resuscitation program. Two of the cases were in-hospital cardiac arrests, whereas the other 2 were out-of-hospital cardiac arrests. The Life-Stat 1008 device was utilized for AM-CPR in all cases. All cases demonstrated confirmed pneumothoraces on post-resuscitation imaging. Several factors may have contributed to the observed pneumothoraces. Two of the cases presented with obstructive lung disease, whereas the other 2 had underlying malignancy. Suboptimal positioning and failure to secure the included shoulder straps could have led to migration of the piston over the ribs. Further study is needed to determine the incidence of complications for all FDA-approved AM-CPR devices compared with manual chest compressions.<\/jats:p>","DOI":"10.4187\/respcare.03334","type":"journal-article","created":{"date-parts":[[2015,1,14]],"date-time":"2015-01-14T02:26:19Z","timestamp":1421202379000},"update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":5,"title":["Pneumothoraces Post Mechanical Cardiopulmonary Resuscitation: A Case Series"],"prefix":"10.1177","volume":"60","author":[{"given":"Sean","family":"Dooley","sequence":"first","affiliation":[{"name":"Division of Internal Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed Mohsen","family":"Mansour","sequence":"additional","affiliation":[{"name":"Division of Pulmonary and Critical Care, Department of Medicine, Stony Brook University Hospital, Stony Brook, New York."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2015,7,1]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.110.970988"},{"issue":"3","key":"e_1_3_2_3_2","first-page":"219","article-title":"Mechanical devices for cardiopulmonary resuscitation","volume":"11","author":"Wigginton JG","year":"2005","unstructured":"Wigginton JG, , Miller AH, , Benitez FL, , Pepe PE. Mechanical devices for cardiopulmonary resuscitation. Curr Opin Crit Care, 2005; 11(3):219\u2013223.","journal-title":"Curr Opin Crit Care"},{"key":"e_1_3_2_4_2","unstructured":"ZOLL AutoPulse resuscitation system model 100 user guide. http:\/\/www.zoll.com\/WorkArea\/DownloadAsset.aspx?id=21383. Accessed December 26 2014."},{"key":"e_1_3_2_5_2","first-page":"381798","article-title":"Successful prolonged mechanical CPR in a severely poisoned hypothermic patient: a case report","volume":"2012","author":"Piacentini A","year":"2012","unstructured":"Piacentini A, , Volonte M, , Rigamonti M, , Guastella E, , Landriscina M. Successful prolonged mechanical CPR in a severely poisoned hypothermic patient: a case report. Case Rep Emerg Med, 2012; 2012:381798.","journal-title":"Case Rep Emerg Med"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2005.05.024"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2004.01.025"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2004.12.006"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e31828a24e3"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1186\/1471-227X-12-8"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/1757-7241-20-39"},{"issue":"1","key":"e_1_3_2_12_2","first-page":"CD007260","article-title":"Mechanical versus manual chest compressions for cardiac arrest","author":"Brooks SC","year":"2011","unstructured":"Brooks SC, , Bigham BL, , Morrison LJ. Mechanical versus manual chest compressions for cardiac arrest. Cochrane Database Syst Rev, 2011(1):CD007260.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2009.06.010"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/1556-4029.12146"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-0644(85)80795-2"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1007\/s004140050123"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0300-9572(99)00033-7"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resuscitation.2004.05.019"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1136\/emj.2006.035725"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e31825d924d"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.4187\/respcare.03334","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.03334","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.03334","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T06:11:57Z","timestamp":1777615917000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.4187\/respcare.03334"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,7]]},"references-count":19,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2015,7]]}},"alternative-id":["10.4187\/respcare.03334"],"URL":"https:\/\/doi.org\/10.4187\/respcare.03334","relation":{},"ISSN":["0020-1324"],"issn-type":[{"value":"0020-1324","type":"print"}],"subject":[],"published":{"date-parts":[[2015,7]]}}}