{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:31:34Z","timestamp":1787031094415,"version":"build-2736575974"},"reference-count":15,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2014,11,25]],"date-time":"2014-11-25T00:00:00Z","timestamp":1416873600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respir Care"],"published-print":{"date-parts":[[2015,3]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>\n                      Portable oxygen devices simplify and facilitate patient therapy. This study was designed to compare S\n                      <jats:sub>\n                        pO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      and patient satisfaction with a portable oxygen concentrator or a combined system consisting of a fixed device with continuous-flow oxygen dispensation and a portable device with pulse dispensation for ambulation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      This crossover trial assessed 25 subjects with COPD (92% men, mean age of 72.2 \u00b1 7.4 y, mean FEV\n                      <jats:sub>1<\/jats:sub>\n                      of 34.14 \u00b1 12.51% of predicted) at 4 hospitals in Madrid. All subjects had previously used the combined system, consisting of a fixed oxygenation system and a portable system for ambulation, with 16 (64%) using stationary and portable concentrators and 9 (36%) using a stationary reservoir and portable liquid oxygen bag. Oxygenation settings at rest and while walking were determined at baseline. Subjects were maintained on the previous combined system for 1 week and then switched to the portable oxygen concentrator for 1 week. Mean S\n                      <jats:sub>\n                        pO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      over 24 h was calculated using the software in the oximeter, and compliance was monitored (Visionox).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Low S\n                      <jats:sub>\n                        pO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      (&lt; 90%) was significantly more frequent during use of the portable concentrator alone than with the combined system (37.1% vs 18.4%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .05). The portable system alone was preferred by 43% of subjects, and the combined system was preferred by 36%, whereas 21% were not sure.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Subjects preferred using a single portable oxygenation system both at home and during ambulation. Portable systems alone, however, did not supply the same levels of oxygenation as the combination of fixed and portable systems. Before the widespread adoption of portable systems as a single device, additional studies are needed to determine best-practice protocols for adjustment of daytime and nighttime oxygenation settings. (ClinicalTrials.gov registration NCT02079753)<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4187\/respcare.03470","type":"journal-article","created":{"date-parts":[[2014,11,25]],"date-time":"2014-11-25T21:59:21Z","timestamp":1416952761000},"page":"382-387","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":15,"title":["Oxygenation With a Single Portable Pulse-Dose Oxygen-Conserving Device and Combined Stationary and Portable Oxygen Delivery Devices in Subjects With COPD"],"prefix":"10.1177","volume":"60","author":[{"given":"Aina M","family":"Y\u00e1\u00f1ez","sequence":"first","affiliation":[{"name":"Instituto de Investigaci\u00f3n Sanitaria de Palma (IdISPa), Palma de Mallorca, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jose P","family":"Prat","sequence":"additional","affiliation":[{"name":"Linde Healthcare (Linde M\u00e9dica), Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 L","family":"\u00c1lvarez-Sala","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital Cl\u00ednico de San Carlos, Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myriam","family":"Calle","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital Cl\u00ednico de San Carlos, Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salvador","family":"D\u00edaz Lobato","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital Universitario Ram\u00f3n y Cajal, Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 L Garc\u00eda","family":"Gonzalez","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital Universitario Ram\u00f3n y Cajal, Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 M Rodr\u00edguez","family":"Gonzalez-Moro","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital General Universitario Gregorio Mara\u00f1\u00f3n, Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raul","family":"Galera-Mart\u00ednez","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital Universitario La Paz, Instituto de Investigaci\u00f3n Hospital Universitario La Paz (IdiPAZ), Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carlos","family":"Villasante","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital Universitario La Paz, Instituto de Investigaci\u00f3n Hospital Universitario La Paz (IdiPAZ), Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Inmaculada","family":"Ramos","sequence":"additional","affiliation":[{"name":"Linde Healthcare (Linde M\u00e9dica), Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mercedes","family":"Franco-Gay","sequence":"additional","affiliation":[{"name":"Linde Healthcare (Linde M\u00e9dica), Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pilar","family":"de Lucas","sequence":"additional","affiliation":[{"name":"Servicio de Neumolog\u00eda, Hospital General Universitario Gregorio Mara\u00f1\u00f3n, Madrid, Spain."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2014,11,25]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rmed.2003.10.008"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-93-3-391"},{"issue":"8222","key":"e_1_3_2_4_2","first-page":"681","article-title":"Long-term domiciliary oxygen therapy in chronic hypoxic cor pulmonale complicating chronic bronchitis and emphysema","volume":"1","author":"Medical Research Council Working Party","year":"1981","unstructured":"Medical Research Council Working Party. Long-term domiciliary oxygen therapy in chronic hypoxic cor pulmonale complicating chronic bronchitis and emphysema. Lancet, 1981; 1(8222):681\u2013686.","journal-title":"Lancet"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.02.00284202"},{"issue":"4","key":"e_1_3_2_6_2","first-page":"CD004356","article-title":"Short-term ambulatory oxygen for chronic obstructive pulmonary disease","author":"Bradley JM","year":"2005","unstructured":"Bradley JM, , O'Neill B. Short-term ambulatory oxygen for chronic obstructive pulmonary disease. Cochrane Database Syst Rev, 2005;(4):CD004356.","journal-title":"Cochrane Database Syst Rev"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0954-6111(99)90314-1"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.arbr.2011.12.001"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.94.1.77"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.06510252"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200910-1638OC"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1157\/13097000"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200703-456SO"},{"key":"e_1_3_2_14_2","first-page":"97","article-title":"Monitor de cumplimiento de oxigenoterapia domiciliaria Visionox. Evaluaci\u00f3n de eficacia y fiabilidad","volume":"45","author":"P\u00e9rez de Alejo R","year":"2009","unstructured":"P\u00e9rez de Alejo R, , Esteban R, , Sacrist\u00e1n JC, , Peces-Barba G. Monitor de cumplimiento de oxigenoterapia domiciliaria Visionox. Evaluaci\u00f3n de eficacia y fiabilidad. Arch Bronconeumol, 2009; 45(Esp Congr):97.","journal-title":"Arch Bronconeumol"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.51.8.831"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.09540344"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.4187\/respcare.03470","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.03470","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.03470","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T06:12:35Z","timestamp":1777615955000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.4187\/respcare.03470"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,11,25]]},"references-count":15,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2015,3]]}},"alternative-id":["10.4187\/respcare.03470"],"URL":"https:\/\/doi.org\/10.4187\/respcare.03470","relation":{},"ISSN":["0020-1324"],"issn-type":[{"value":"0020-1324","type":"print"}],"subject":[],"published":{"date-parts":[[2014,11,25]]}}}