{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T00:41:03Z","timestamp":1792629663062,"version":"4.5.0"},"reference-count":26,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2017,10,31]],"date-time":"2017-10-31T00:00:00Z","timestamp":1509408000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respir Care"],"published-print":{"date-parts":[[2018,2]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Esophageal balloon inflation volume may affect the accuracy of transpulmo-nary pressure estimates in adults, but the effect is unknown in pediatrics. Using a combination bench and human study, we sought to determine a range of optimal filling volumes for esophageal balloon catheters and to derive a technique to inflate catheters to yield the most accurate estimates of pleural pressure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>In the laboratory study, we evaluated 4 pediatric and adult esophageal balloon catheters, a liquid-filled catheter, and a micro-tip catheter, both with and without a model esophagus. We compared the measured esophageal pressure for each type of catheter within a pressurized chamber. Esophageal balloon catheters were also tested by manipulating the esophageal balloon inflation volume, and we attempted to derive a filling-volume technique that would assure accuracy. We then tested the feasibility of this technique in 5 mechanically ventilated pediatric subjects with ARDS.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      In the laboratory study, smaller inflation volumes underestimated the chamber pressure at higher chamber pressures, and larger inflation volumes overestimated the chamber pressure at lower chamber pressures. Using an optimal filling-volume technique resulted in a mean total error that ranged from \u22120.53 to \u22120.10 cm H\n                      <jats:sub>2<\/jats:sub>\n                      O. The optimal filling-volume values for the pediatric catheters were 0.2\u20130.6 mL, and 0.4\u20130.8 mL for the adult catheters. When correctly positioned and calibrated, the micro-tip transducer and liquid-filled catheters were within \u00b1 1 cm H\n                      <jats:sub>2<\/jats:sub>\n                      O of chamber pressure for all ranges of pressure. In the clinical study, high variability in measured esophageal pressure and subsequent transpulmonary pressure during exhalation and during inhalation was observed within the manufacturer's recommended esophageal balloon inflation ranges.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Manufacturer-recommended esophageal balloon inflation ranges do not assure accuracy. Individual titration of esophageal balloon volume may improve accuracy. Better esophageal catheters are needed to provide reliable esophageal pressure measurements in children.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4187\/respcare.05685","type":"journal-article","created":{"date-parts":[[2017,10,31]],"date-time":"2017-10-31T20:10:31Z","timestamp":1509480631000},"page":"177-186","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":34,"title":["Measurements Obtained From Esophageal Balloon Catheters Are Affected by the Esophageal Balloon Filling Volume in Children With ARDS"],"prefix":"10.1177","volume":"63","author":[{"given":"Justin C","family":"Hotz","sequence":"first","affiliation":[{"name":"Department of Respiratory Care, Children's Hospital Los Angeles, CA."},{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cary T","family":"Sodetani","sequence":"additional","affiliation":[{"name":"Department of Respiratory Care, Children's Hospital Los Angeles, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey","family":"Van Steenbergen","sequence":"additional","affiliation":[{"name":"Department of Respiratory Care, Children's Hospital Los Angeles, CA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robinder G","family":"Khemani","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, CA."},{"name":"Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy W","family":"Deakers","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, CA."},{"name":"Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J","family":"Newth","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, CA."},{"name":"Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2017,10,31]]},"reference":[{"key":"e_1_3_3_2_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201512-2448CP"},{"issue":"1","key":"e_1_3_3_3_2","first-page":"1","article-title":"The promises and problems of transpulmonary pressure measurements in acute respiratory distress syndrome","volume":"22","author":"Sahetya SK","year":"2016","unstructured":"Sahetya SK, , Brower RG. The promises and problems of transpulmonary pressure measurements in acute respiratory distress syndrome. Curr Opin Crit Care, 2016; 22(1):1\u201313.","journal-title":"Curr Opin Crit Care"},{"key":"e_1_3_3_4_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa0708638"},{"key":"e_1_3_3_5_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-014-3415-4"},{"key":"e_1_3_3_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e3182a05bb8"},{"key":"e_1_3_3_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-012-2490-7"},{"key":"e_1_3_3_8_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.200710-1589OC"},{"key":"e_1_3_3_9_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201312-2193CI"},{"key":"e_1_3_3_10_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.164.1.2007011"},{"key":"e_1_3_3_11_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1992.72.1.383"},{"issue":"8","key":"e_1_3_3_12_2","first-page":"855","article-title":"Esophageal pressure measurements under different conditions of intrathoracic pressure: An in vitro study of second generation balloon catheters","volume":"81","author":"Mojoli F","year":"2015","unstructured":"Mojoli F, , Chiumello D, , Pozzi M, , Algieri I, , Bianzina S, , Luoni S, et al. Esophageal pressure measurements under different conditions of intrathoracic pressure: An in vitro study of second generation balloon catheters. Minerva Anestesiol, 2015; 81(8):855\u2013864.","journal-title":"Minerva Anestesiol"},{"key":"e_1_3_3_13_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.02974"},{"key":"e_1_3_3_14_2","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-016-1278-5"},{"issue":"3","key":"e_1_3_3_15_2","first-page":"261","article-title":"Evaluation of instrument error and method agreement","volume":"64","author":"Chatburn RL","year":"1996","unstructured":"Chatburn RL. Evaluation of instrument error and method agreement. AANA J, 1996; 64(3):261\u2013268.","journal-title":"AANA J"},{"key":"e_1_3_3_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0b013e31823bc61b"},{"key":"e_1_3_3_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/PCC.0000000000000350"},{"issue":"8","key":"e_1_3_3_18_2","first-page":"959","article-title":"Esophageal pressure: benefit and limitations","volume":"78","author":"Hedenstierna G","year":"2012","unstructured":"Hedenstierna G. Esophageal pressure: benefit and limitations. Minerva Anestesiol, 2012; 78(8):959\u2013966.","journal-title":"Minerva Anestesiol"},{"key":"e_1_3_3_19_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.01883"},{"key":"e_1_3_3_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.CCM.0000215515.49001.A2"},{"key":"e_1_3_3_21_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1955.7.5.491"},{"key":"e_1_3_3_22_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1958.13.3.481"},{"key":"e_1_3_3_23_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1959.14.4.535"},{"key":"e_1_3_3_24_2","doi-asserted-by":"publisher","DOI":"10.1152\/jappl.1989.67.2.889"},{"key":"e_1_3_3_25_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0103057"},{"key":"e_1_3_3_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-011-2372-4"},{"issue":"5","key":"e_1_3_3_27_2","first-page":"1158","article-title":"The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies","volume":"49","author":"Piper I","year":"2001","unstructured":"Piper I, , Barnes A, , Smith D, , Dunn L. The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies. Neurosurgery, 2001; 49(5):1158\u20131165.","journal-title":"Neurosurgery"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.4187\/respcare.05685","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.05685","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.05685","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T09:26:42Z","timestamp":1775467602000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.4187\/respcare.05685"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10,31]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018,2]]}},"alternative-id":["10.4187\/respcare.05685"],"URL":"https:\/\/doi.org\/10.4187\/respcare.05685","relation":{},"ISSN":["0020-1324"],"issn-type":[{"value":"0020-1324","type":"print"}],"subject":[],"published":{"date-parts":[[2017,10,31]]}}}