{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T11:57:55Z","timestamp":1775476675251,"version":"3.50.1"},"reference-count":33,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[2017,12,12]],"date-time":"2017-12-12T00:00:00Z","timestamp":1513036800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respir Care"],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:sec>\n                    <jats:title>INTRODUCTION:<\/jats:title>\n                    <jats:p>The incremental shuttle walk test was initially developed to be carried out in a hallway (ISWT-H) but has been modified to be performed on a treadmill (ISWT-T). However, it is still unknown whether performance on ISWT-H and ISWT-T are similar in patients with bronchiectasis. In this study, we compared the performance, physiological responses, and perception of effort between the ISWT-T with a handrail and ISWT-H for subjects with bronchiectasis. We also sought to estimate and compare the prescription for training intensity with both tests.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      This was a cross-sectional study in which 24 subjects with bronchiectasis were evaluated on 2 different days (24 h apart). Distance walked (m) was compared between the ISWT-H and ISWT-T. A training session was held on a treadmill at 75% of the speed obtained from both tests. The walking distance, oxygen uptake (V\u0307\n                      <jats:sub>\n                        O\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      ), carbon dioxide production (V\u0307\n                      <jats:sub>\n                        CO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      ), heart rate, and ventilation (V\u0307\n                      <jats:sub>E<\/jats:sub>\n                      ) were measured.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      There was a difference in the walking distance between the ISWT-T and ISWT-H, but physiological responses for V\u0307\n                      <jats:sub>\n                        O\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      , V\u0307\n                      <jats:sub>\n                        CO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      , heart rate, and V\u0307\n                      <jats:sub>E<\/jats:sub>\n                      were similar. However, the speed estimated for training was different, as were the V\u0307\n                      <jats:sub>\n                        O\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      , V\u0307\n                      <jats:sub>\n                        CO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      , and heart rate.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>The ISWT-T with handrail and the ISWT-H are not interchangeable in subjects with bronchiectasis. A slower speed of training intensity may occur when the test is performed in a hallway, as originally described, and this may underestimate responses to aerobic training<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4187\/respcare.05735","type":"journal-article","created":{"date-parts":[[2017,12,12]],"date-time":"2017-12-12T20:25:18Z","timestamp":1513110318000},"page":"311-318","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":2,"title":["Incremental Shuttle Walk Test to Assess and Prescribe Exercise for Subjects With Bronchiectasis: Hallway Versus Treadmill"],"prefix":"10.1177","volume":"63","author":[{"given":"Cristiane S","family":"Oliveira","sequence":"first","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anderson","family":"Jos\u00e9","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Crislaine O","family":"Santos","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cristiane H Y","family":"de Oliveira","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thiago C O","family":"Carvalho","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rejane A S","family":"de Castro","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessyca P R","family":"Selman","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anderson A","family":"de Camargo","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simone","family":"Dal Corso","sequence":"additional","affiliation":[{"name":"Rehabilitation Sciences, Universidade Nove de Julho, S\u00e3o Paulo\/SP, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2017,12,12]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.47.12.1019"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1186\/1465-9921-15-44"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1183\/20734735.021314"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.160.5.9808139"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.09541712"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1093\/ptj\/70.7.439"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.40.6.459"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1053\/rmed.2003.1501"},{"issue":"9","key":"e_1_3_2_10_2","first-page":"e005216","article-title":"Pilot investigation of the oxygen demands and metabolic cost of incremental shuttle walking and treadmill walking in patients with cardiovascular disease","volume":"4","author":"Almodhy M","year":"2014","unstructured":"Almodhy M, , Beneke R, , Cardoso F, , Taylor MJ, , Sandercock GR. Pilot investigation of the oxygen demands and metabolic cost of incremental shuttle walking and treadmill walking in patients with cardiovascular disease. BMJ, 2014; 4(9):e005216.","journal-title":"BMJ"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.01380.2006"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.gaitpost.2009.06.017"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2008.06.039"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2008.05.024"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00150314"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00005768-199606000-00014"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.70252\/ECYF1853"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/00008483-200611000-00009"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1152\/japplphysiol.00554.2011"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/00008483-199107000-00008"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201309-1634ST"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.2010.136119"},{"key":"e_1_3_2_23_2","first-page":"1","article-title":"Physical status: the use and interpretation of anthropometry","volume":"854","author":"WHO Expert Committee","year":"1995","unstructured":"WHO Expert Committee. Physical status: the use and interpretation of anthropometry. World Health Organ Tech Rep Ser, 1995; 854:1\u2013452.","journal-title":"World Health Organ Tech Rep Ser"},{"key":"e_1_3_2_24_2","first-page":"S44","article-title":"Diretrizes para testes da fun\u00e7\u00e3o pulmonar","volume":"28","author":"Sociedade Brasileira de Pneumologia","year":"2002","unstructured":"Sociedade Brasileira de Pneumologia. Diretrizes para testes da fun\u00e7\u00e3o pulmonar. J Pneumol, 2002; 28(Suppl 3):S44\u2013S58.","journal-title":"J Pneumol"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1590\/S1806-37132007000400008"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1590\/S1806-37132008001200005"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1249\/00005768-198205000-00012"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rmed.2011.07.023"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1249\/MSS.0b013e318213fefb"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm\/143.1.9"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1098-240X(200002)23:1<35::AID-NUR5>3.0.CO;2-I"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.13-2071"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.54.3.213"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rmed.2012.08.011"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.4187\/respcare.05735","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.05735","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.05735","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T11:08:46Z","timestamp":1775473726000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.4187\/respcare.05735"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12,12]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018,3]]}},"alternative-id":["10.4187\/respcare.05735"],"URL":"https:\/\/doi.org\/10.4187\/respcare.05735","relation":{},"ISSN":["0020-1324"],"issn-type":[{"value":"0020-1324","type":"print"}],"subject":[],"published":{"date-parts":[[2017,12,12]]}}}