{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T05:50:45Z","timestamp":1776837045815,"version":"3.51.2"},"reference-count":21,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2018,9,25]],"date-time":"2018-09-25T00:00:00Z","timestamp":1537833600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respir Care"],"published-print":{"date-parts":[[2019,2]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>\n                      Widespread use of transcutaneous P\n                      <jats:sub>\n                        CO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      (P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      ) monitoring is currently limited by concerns many practitioners have regarding accuracy. We compared the accuracy of P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      with that of P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      measurements in critically ill children, and we investigated whether clinical conditions associated with low cardiac output or increased subcutaneous tissue affect this accuracy.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>We performed a single-center prospective study of critically ill children placed on transcutaneous monitoring.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      There were 184 children enrolled with paired P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      and P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      values. Subjects had a median age of 31.8 mo (interquartile range 3.5\u2013123.3 mo). Most children were mechanically ventilated (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 161, 87.5%), and many had cardiac disease (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 76, 41.3%). The median P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      was 44 mm Hg (interquartile range 39\u201351 mm Hg). The mean bias between P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      and P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      was 0.6 mm Hg with 95% limits of agreement from \u221213.6 to 14.7 mm Hg. The P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      and P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      were within \u00b15 mm Hg in 126 (68.5%) measurements. In multivariable modeling, cyanotic heart disease (odds ratio 3.5, 95% CI 1.2\u201310,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .02) and monitor number 2 (odds ratio 3.8 95% CI 1.3\u201310.5,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .01) remained associated with P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      \u2265 5 mm Hg higher than P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      . Serum lactate, fluid balance, renal failure, obesity, vasoactive-inotrope score, and acyanotic heart disease were not associated with high or low P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      values. In 130 children with a second paired P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      and P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      measurement, predicting the second measured P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      by subtracting the initial observed difference between the P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      and P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      from the subsequent measured P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      decreased the mean bias between observed and predicted P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      to 0.2 mm Hg and the 95% limits of agreement to \u22129.4 to 9.7 mm Hg.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>\n                      P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      provides an acceptable estimate of P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      in many critically ill children, including those with clinical conditions that may be associated with low cardiac output or increased subcutaneous tissue, although it does not perform as well in children with cyanotic heart disease. P\n                      <jats:sub>\n                        tcCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      may be a useful adjunct monitoring method, but it cannot reliably replace P\n                      <jats:sub>\n                        aCO\n                        <jats:sub>2<\/jats:sub>\n                      <\/jats:sub>\n                      measurement.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4187\/respcare.06209","type":"journal-article","created":{"date-parts":[[2018,9,25]],"date-time":"2018-09-25T14:35:18Z","timestamp":1537886118000},"page":"201-208","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":13,"title":["Accuracy of Transcutaneous Carbon Dioxide Levels in Comparison to Arterial Carbon Dioxide Levels in Critically Ill Children"],"prefix":"10.1177","volume":"64","author":[{"given":"Anoopindar K","family":"Bhalla","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, Los Angeles, California."},{"name":"Keck School of Medicine, University of Southern California, Los Angeles, California."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robinder G","family":"Khemani","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, Los Angeles, California."},{"name":"Keck School of Medicine, University of Southern California, Los Angeles, California."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Justin C","family":"Hotz","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, Los Angeles, California."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rica P","family":"Morzov","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, Los Angeles, California."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher JL","family":"Newth","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Critical Care Medicine, Children's Hospital Los Angeles, Los Angeles, California."},{"name":"Keck School of Medicine, University of Southern California, Los Angeles, California."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2018,9,25]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1002\/ppul.1950120305"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1213\/01.ane.0000278642.16117.f8"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.05243"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003246-200205000-00011"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1002\/ppul.21203"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2009.02930.x"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2007.04987.x"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.3109\/00365510903450106"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.4103\/1817-1737.84776"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.08531042"},{"issue":"3","key":"e_1_3_2_12_2","first-page":"531","article-title":"Transcutaneous monitoring of carbon dioxide tension after cardiothoracic surgery in infants and children","volume":"88","author":"Tobias JD","year":"1999","unstructured":"Tobias JD, , Wilson WRJr, , Meyer DJ. Transcutaneous monitoring of carbon dioxide tension after cardiothoracic surgery in infants and children. Anesth Analg, 1999; 88(3):531\u2013534.","journal-title":"Anesth Analg"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-016-9903-z"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/PCC.0b013e3182192c42"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/CCM.0000000000001199"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-198902000-00007"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/PCC.0000000000000434"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-011-2367-1"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.clinbiochem.2015.12.015"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/PCC.0000000000000660"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.2013-1760"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.3109\/00365513.2011.590601"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.4187\/respcare.06209","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.06209","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.06209","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,8]],"date-time":"2026-04-08T05:27:48Z","timestamp":1775626068000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.4187\/respcare.06209"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,25]]},"references-count":21,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["10.4187\/respcare.06209"],"URL":"https:\/\/doi.org\/10.4187\/respcare.06209","relation":{},"ISSN":["0020-1324"],"issn-type":[{"value":"0020-1324","type":"print"}],"subject":[],"published":{"date-parts":[[2018,9,25]]}}}