{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T09:54:53Z","timestamp":1775469293260,"version":"3.50.1"},"reference-count":37,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2020,8,25]],"date-time":"2020-08-25T00:00:00Z","timestamp":1598313600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respir Care"],"published-print":{"date-parts":[[2021,2]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Inhaled nitric oxide (NO) is most frequently delivered to mechanically ventilated patients in critical care, but it can also be administered noninvasively. The delivered dose and efficiency of continuous flow NO supplied through a nasal cannula has yet to be established. This study aimed to determine the influence of nasal cannula type, supply flow, and breathing pattern on delivered NO using a realistic adult airway replica and lung simulator.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      Simulated breathing patterns were selected to represent rest, sleep, and light exercise, and were varied to investigate the effects of tidal volume and breathing frequency independently. Supplied gas flows targeted tracheal concentrations at rest of 5 or 20 ppm NO and were supplied with 2 L\/min O\n                      <jats:sub>2<\/jats:sub>\n                      . Three different cannulas were tested. Tracheal NO concentrations and NO mass flow past the trachea were evaluated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      Cannula type had a minor influence on delivered dose. Tracheal NO concentrations differed significantly based on breathing pattern (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.01); for a target NO concentration of 20 ppm at rest, average inhaled NO concentrations were 23.3 \u00b1 0.5 ppm, 36.5 \u00b1 1.4 ppm, and 17.2 \u00b1 0.3 ppm for the rest, sleep, and light exercise breathing patterns, respectively. For the same test conditions, mass flow of NO past the trachea was less sensitive to breathing pattern: 20.3 \u00b1 0.5 mg\/h, 19.9 \u00b1 0.8 mg\/h, and 24.3 \u00b1 0.4 mg\/h for the rest, sleep, and light exercise breathing patterns, respectively. Mass flow and delivery efficiency increased when minute volume increased.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>These results indicate that inhaled NO concentration is strongly influenced by breathing pattern, whereas inhaled NO mass flow is not. NO mass flow may therefore be a useful dose metric for continuous flow delivery via nasal cannula.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4187\/respcare.07737","type":"journal-article","created":{"date-parts":[[2020,8,25]],"date-time":"2020-08-25T17:15:17Z","timestamp":1598375717000},"page":"228-239","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["Inhaled Nitric Oxide: In Vitro Analysis of Continuous Flow Noninvasive Delivery via Nasal Cannula"],"prefix":"10.1177","volume":"66","author":[{"given":"Kineshta","family":"Pillay","sequence":"first","affiliation":[{"name":"Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John Z","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Warren H","family":"Finlay","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrew R","family":"Martin","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2020,8,25]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.83.6.2038"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1542\/peds.106.2.344"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-012-0172-4"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1532\/HSF98.20041136"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1186\/cc7734"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMra051884"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-016-0227-5"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.niox.2015.08.007"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2018.08.004"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1399-6576.1997.tb04794.x"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-199703000-00021"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/79.3.398"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(00)03548-0"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-38664-0_11"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.4103\/2045-8932.97589"},{"key":"e_1_3_2_17_2","unstructured":"Quinn D. on behalf of Bellerophon Pulse Technologies. Clinical study of pulsed inhaled nitric oxide versus placebo in symptomatic subjects with PAH (INOvation-1). Aug 6 2019. Available at: https:\/\/clinicaltrials.gov\/ct2\/show\/study\/NCT02725372. Accessed September 5 2019."},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/1479972308090691"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1186\/2045-9912-4-1"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.2147\/COPD.S106480"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1097\/INF.0000000000001780"},{"key":"e_1_3_2_22_2","article-title":"Protocol for a randomized controlled trial testing inhaled nitric oxide therapy in spontaneously breathing patients with COVID-19","author":"Berra L","year":"2020","unstructured":"Berra L, , Lei C, , Su B, , Dong H, , Fakhr BS, , Grassi LG, et al. Protocol for a randomized controlled trial testing inhaled nitric oxide therapy in spontaneously breathing patients with COVID-19. medRxiv, 2020 [Epub ahead of print].","journal-title":"medRxiv"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.2147\/COPD.S141976"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.06359"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12931-019-1104-0"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.06243"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaerosci.2011.04.002"},{"key":"e_1_3_2_28_2","unstructured":"US Food and Drug Administration. Guidance document for premarket notification submissions for nitric oxide delivery apparatus nitric oxide analyzer and nitrogen dioxide analyzer. 2000. Available at: https:\/\/www.fda.gov\/regulatory-information\/search-fda-guidance-documents\/guidance-document-premarket-notification-submissions-nitric-oxide-delivery-apparatus-nitric-oxide. Accessed August 4 2020."},{"key":"e_1_3_2_29_2","volume-title":"The mechanics of inhaled pharmaceutical aerosols: an introduction","author":"Finlay WH","year":"2001","unstructured":"Finlay WH. The mechanics of inhaled pharmaceutical aerosols: an introduction. San Diego: Academic Press; 2001."},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.126.4.1108"},{"issue":"3","key":"e_1_3_2_31_2","first-page":"669","article-title":"Contribution of hypoventilation to sleep oxygen desaturation in chronic obstructive pulmonary disease","volume":"55","author":"Hudgel DW","year":"1983","unstructured":"Hudgel DW, , Martin RJ, , Capehart M, , Johnson B, , Hill P. Contribution of hypoventilation to sleep oxygen desaturation in chronic obstructive pulmonary disease. J Appl Physiol Respir Environ Exerc Physiol, 1983; 55(3):669-677.","journal-title":"J Appl Physiol Respir Environ Exerc Physiol"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1469-8986.1985.tb01560.x"},{"key":"e_1_3_2_33_2","first-page":"327","volume-title":"An introduction to error analysis: the study of uncertainties in physical measurements","author":"Taylor JR","year":"1997","unstructured":"Taylor JR. An introduction to error analysis: the study of uncertainties in physical measurements. Sausalito, CA: University Science Books; 1997:327."},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2018.10.008"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.03278"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1006\/niox.1999.0232"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaerosci.2017.12.004"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1111\/resp.12268"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.4187\/respcare.07737","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.07737","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.07737","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T08:56:12Z","timestamp":1775465772000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.4187\/respcare.07737"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,25]]},"references-count":37,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["10.4187\/respcare.07737"],"URL":"https:\/\/doi.org\/10.4187\/respcare.07737","relation":{},"ISSN":["0020-1324"],"issn-type":[{"value":"0020-1324","type":"print"}],"subject":[],"published":{"date-parts":[[2020,8,25]]}}}