{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T16:46:44Z","timestamp":1792169204697,"version":"4.4.0"},"reference-count":40,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2022,10,11]],"date-time":"2022-10-11T00:00:00Z","timestamp":1665446400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Respir Care"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Noninvasive ventilation (NIV) is the reference standard treatment for most situations of chronic respiratory failure. NIV settings must be titrated to both preserve upper-airway patency and control hypoventilation. Automatic adjustment of pressure support (PS) and expiratory positive airway pressure (EPAP) may facilitate the initiation and follow-up of domiciliary NIV. However, whether the automatic-adjustment algorithms embedded into current devices accurately detect, respond to, and score common sleep-related respiratory events remains unclear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>A bench was set up to simulate central hypopnea (CH), central apnea (CA), obstructive hypopnea (OH), and obstructive apnea (OA). Four home ventilators were evaluated, with their dedicated modes for automatic PS and EPAP adjustment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>All 4 devices increased PS during CH, CA, and OH. However, PS adjustment varied widely in magnitude, with tidal volumes within 100 \u00b1 20% of the target being provided by only 3 devices for CH, one for CA, and one for OH. Two devices increased EPAP for OH and 3 for OA, including one that also increased EPAP for CA. Only 2 devices scored residual hypopnea after simulated CA, and only one scored a residual event after OH. One device scored no event.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>Current NIV devices differed markedly in their responses to, and reporting of, standardized sleep-related respiratory events. Further improvements in embedded NIV algorithms are needed to allow more widespread out-of-laboratory initiation and follow-up of NIV.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4187\/respcare.09807","type":"journal-article","created":{"date-parts":[[2022,10,11]],"date-time":"2022-10-11T08:45:11Z","timestamp":1665477911000},"page":"18-30","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":12,"title":["Noninvasive Ventilation Automated Technologies: A Bench Evaluation of Device Responses to Sleep-Related Respiratory Events"],"prefix":"10.1177","volume":"68","author":[{"given":"Mathieu","family":"Delorme","sequence":"first","affiliation":[{"name":"Universit\u00e9 Paris-Saclay, UVSQ, ERPHAN, Versailles, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl","family":"Leroux","sequence":"additional","affiliation":[{"name":"ASV Sant\u00e9, Gennevilliers, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antoine","family":"Leotard","sequence":"additional","affiliation":[{"name":"Service de physiologie - explorations fonctionnelles, Unit\u00e9 des pathologies du sommeil, AP-HP, H\u00f4pital Raymond Poincar\u00e9, Garches, France; and Universit\u00e9 Paris-Saclay, UVSQ, INSERM U1179, Equipe 3, Versailles, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ghilas","family":"Boussaid","sequence":"additional","affiliation":[{"name":"Universit\u00e9 Paris-Saclay, UVSQ, ERPHAN, Versailles, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Helene","family":"Prigent","sequence":"additional","affiliation":[{"name":"Service de physiologie - explorations fonctionnelles, Unit\u00e9 des pathologies du sommeil, AP-HP, H\u00f4pital Raymond Poincar\u00e9, Garches, France; and Universit\u00e9 Paris-Saclay, UVSQ, INSERM U1179, Equipe 3, Versailles, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruno","family":"Louis","sequence":"additional","affiliation":[{"name":"INSERM, U955, Universit\u00e9 Paris Est Cr\u00e9teil, Facult\u00e9 de M\u00e9decine, CNRS ERL 7000, Cr\u00e9teil, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frederic","family":"Lofaso","sequence":"additional","affiliation":[{"name":"Universit\u00e9 Paris-Saclay, UVSQ, ERPHAN, Versailles, France; and Service de physiologie - explorations fonctionnelles, Unit\u00e9 des pathologies du sommeil, AP-HP, H\u00f4pital Raymond Poincar\u00e9, Garches, France."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2022,10,11]]},"reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2017.4451"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2016-208501"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.53.11.949"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1474-4422(05)70326-4"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2019-214204"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(94)93058-9"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2020.02.064"},{"issue":"63","key":"e_1_3_2_9_2","article-title":"The prevalence of chronic respiratory failure treated with home mechanical ventilation in Helsinki, Finland","volume":"54","author":"Kotanen P","year":"2019","unstructured":"Kotanen P, , Kreivi H-R, , Kainu A, , Brander P. The prevalence of chronic respiratory failure treated with home mechanical ventilation in Helsinki, Finland. Eur Respir J, 2019; 54(suppl 63). [Internet][cited 2021 Mar 5] Available from: https:\/\/erj.ersjournals.com\/content\/54\/suppl_63\/PA2311.","journal-title":"Eur Respir J"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.01003-2019"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1164\/rccm.201905-1071ST"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1177\/0883073807305788"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.116.2.521"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rmed.2017.10.025"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.chest.2017.06.036"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/resp.13631"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.27941"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1136\/thoraxjnl-2018-213022"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/resp.13497"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1183\/13993003.01721-2015"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1136\/thx.2010.139782"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00170508"},{"key":"e_1_3_2_23_2","first-page":"40","article-title":"Prognostic value of initial assessment of residual hypoventilation using nocturnal capnography in mechanically ventilated neuromuscular Patients: a 5-year follow-up study","volume":"3","author":"Ogna A","year":"2016","unstructured":"Ogna A, , Nardi J, , Prigent H, , Quera Salva M-A, , Chaffaut C, , Lamothe L, et al. Prognostic value of initial assessment of residual hypoventilation using nocturnal capnography in mechanically ventilated neuromuscular Patients: a 5-year follow-up study. Front Med (Lausanne), 2016; 3:40.","journal-title":"Front Med (Lausanne)"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0012-3692(15)51841-2"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.03633"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.07213"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.resp.2008.03.014"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.2982"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1183\/09031936.00144807"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1440-1843.2009.01691.x"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1378\/chest.11-0485"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.rmed.2013.03.013"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.03413"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.27133"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.2172"},{"issue":"3","key":"e_1_3_2_36_2","first-page":"500","article-title":"Upper-airway patency in the human infant: influence of airway pressure and posture","volume":"48","author":"Wilson SL","year":"1980","unstructured":"Wilson SL, , Thach BT, , Brouillette RT, , Abu-Osba YK. Upper-airway patency in the human infant: influence of airway pressure and posture. J Appl Physiol Respir Environ Exerc Physiol, 1980; 48(3):500-504.","journal-title":"J Appl Physiol Respir Environ Exerc Physiol"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm\/137.6.1379"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1164\/ajrccm.158.5.9711106"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1111\/resp.13784"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1111\/resp.13546"},{"key":"e_1_3_2_41_2","doi-asserted-by":"publisher","DOI":"10.5664\/jcsm.7640"}],"container-title":["Respiratory Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.4187\/respcare.09807","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.09807","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.4187\/respcare.09807","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T10:30:05Z","timestamp":1787135405000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.4187\/respcare.09807"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,11]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"alternative-id":["10.4187\/respcare.09807"],"URL":"https:\/\/doi.org\/10.4187\/respcare.09807","relation":{},"ISSN":["0020-1324"],"issn-type":[{"value":"0020-1324","type":"print"}],"subject":[],"published":{"date-parts":[[2022,10,11]]}}}