{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,4]],"date-time":"2025-12-04T18:39:04Z","timestamp":1764873544546},"reference-count":24,"publisher":"Europa Digital & Publishing","issue":"11","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["EuroIntervention"],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.4244\/eij-d-17-00355","type":"journal-article","created":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T07:23:22Z","timestamp":1513841002000},"page":"1288-1295","source":"Crossref","is-referenced-by-count":14,"title":["A novel synchronised diastolic injection method to reduce contrast volume during aortography for aortic regurgitation assessment: in vitro experiment of a transcatheter heart valve model"],"prefix":"10.4244","volume":"13","author":[{"given":"Yosuke","family":"Miyazaki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad","family":"Abdelghani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ellen","family":"de Boer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Paul","family":"Aben","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Math","family":"van Sloun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Todd","family":"Suchecki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcel","family":"van 't Veer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlos","family":"Collet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taku","family":"Asano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuki","family":"Katagiri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erhan","family":"Tenekecioglu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osama","family":"Soliman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshinobu","family":"Onuma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robbert","family":"de Winter","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pim","family":"Tonino","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frans","family":"van de Vosse","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcel","family":"Rutten","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick","family":"Serruys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2774","reference":[{"key":"key-20171220194044-0","doi-asserted-by":"publisher","first-page":"1686","DOI":"10.1056\/NEJMoa1200384","article-title":"Two-year outcomes after transcatheter or surgical aortic-valve replacement.","volume":"366","author":"Kodali SK.","year":"2012","journal-title":"N Engl J Med."},{"key":"key-20171220194044-1","doi-asserted-by":"publisher","first-page":"449","DOI":"10.1093\/eurheartj\/ehu384","article-title":"Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes.","volume":"36","author":"Kodali S.","year":"2015","journal-title":"Eur Heart J."},{"key":"key-20171220194044-2","doi-asserted-by":"publisher","first-page":"1585","DOI":"10.1016\/j.jacc.2013.01.047","article-title":"Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature.","volume":"61","author":"Athappan G.","year":"2013","journal-title":"J Am Coll Cardiol."},{"key":"key-20171220194044-3","doi-asserted-by":"publisher","first-page":"2627","DOI":"10.1093\/eurheartj\/ehw115","article-title":"Adjudicating paravalvular leaks of transcatheter aortic valves: a critical appraisal.","volume":"37","author":"Abdelghani M.","year":"2016","journal-title":"Eur Heart J."},{"key":"key-20171220194044-4","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1097\/01.rli.0000178434.43939.a4","article-title":"Use of iso-osmolar nonionic dimeric contrast media in multidetector row computed tomography angiography for patients with renal impairment.","volume":"40","author":"Becker CR.","year":"2005","journal-title":"Invest Radiol."},{"key":"key-20171220194044-5","doi-asserted-by":"publisher","first-page":"1274","DOI":"10.2215\/CJN.01260308","article-title":"Incidence and outcomes of contrast-induced AKI following computed tomography.","volume":"3","author":"Weisbord SD.","year":"2008","journal-title":"Clin J Am Soc Nephrol."},{"key":"key-20171220194044-6","doi-asserted-by":"publisher","first-page":"650","DOI":"10.1002\/ccd.26926","article-title":"Angiographic assessment of aortic regurgitation by video-densitometry in the setting of TAVI: Echocardiographic and clinical correlates.","volume":"90","author":"Abdelghani M.","year":"2017","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-20171220194044-7","doi-asserted-by":"publisher","first-page":"1409","DOI":"10.4244\/EIJV11I12A271","article-title":"Video densitometric assessment of aortic regurgitation after transcatheter aortic valve implantation: results from the Brazilian TAVI registry.","volume":"11","author":"Tateishi H.","year":"2016","journal-title":"EuroIntervention."},{"key":"key-20171220194044-8","doi-asserted-by":"publisher","first-page":"60","DOI":"10.4244\/EIJ-D-16-00647","article-title":"The interaction of de novo and pre-existing aortic regurgitation after TAVI: insights from a new quantitative aortographic technique.","volume":"13","author":"Tateishi H.","year":"2017","journal-title":"EuroIntervention."},{"key":"key-20171220194044-9","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1088\/0967-3334\/35\/4\/687","article-title":"A mock circulation model for cardiovascular device evaluation.","volume":"35","author":"Schampaert S.","year":"2014","journal-title":"Physiol Meas."},{"key":"key-20171220194044-10","doi-asserted-by":"publisher","first-page":"891","DOI":"10.1088\/0967-3334\/25\/4\/009","article-title":"A physiologically representative in vitro model of the coronary circulation.","volume":"25","author":"Geven MC.","year":"2004","journal-title":"Physiol Meas."},{"key":"key-20171220194044-11","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1038\/217086b0","article-title":"Mechanism of closure of the aortic valve.","volume":"217","author":"Bellhouse BJ.","year":"1968","journal-title":"Nature."},{"key":"key-20171220194044-12","article-title":"Standard I. Cardiovascular implants \u2014 Cardiac valve prostheses \u2014 Part 1: General requirements.","year":"https:\/\/www.iso.org\/obp\/ui\/#iso:std:iso:5840:-1:ed-1:v1:en","journal-title":"ISO Copyright Office 2015."},{"key":"key-20171220194044-13","doi-asserted-by":"publisher","first-page":"355","DOI":"10.4244\/EIJY14M05_06","article-title":"An objective and reproducible method for quantification of aortic regurgitation after TAVI.","volume":"10","author":"Schultz CJ.","year":"2014","journal-title":"EuroIntervention."},{"key":"key-20171220194044-14","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1111\/jebm.12208","article-title":"The effects of contrast media volume on acute kidney injury after transcatheter aortic valve replacement: a systematic review and meta-analysis.","volume":"9","author":"Thongprayoon C.","year":"2016","journal-title":"J Evid Based Med."},{"key":"key-20171220194044-15","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1007\/s00330-011-2233-0","article-title":"Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.","volume":"22","author":"Wuest W.","year":"2012","journal-title":"Eur Radiol."},{"key":"key-20171220194044-16","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1093\/ehjci\/jew182","article-title":"Feasibility of ultra-low contrast 64-slice computed tomography angiography before transcatheter aortic valve implantation: a real-world experience.","volume":"17","author":"Spagnolo P.","year":"2016","journal-title":"Eur Heart J Cardiovasc Imaging."},{"key":"key-20171220194044-17","doi-asserted-by":"publisher","first-page":"4497","DOI":"10.1007\/s00330-016-4320-8","article-title":"Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation.","volume":"26","author":"Bittner DO.","year":"2016","journal-title":"Eur Radiol."},{"key":"key-20171220194044-18","first-page":"459","article-title":"Radiation Exposure and Contrast Agent Reduction During Transcatheter Aortic Valve Implantation: An Ongoing Experience.","volume":"28","author":"Maccagni D.","year":"2016","journal-title":"J Invasive Cardiol."},{"key":"key-20171220194044-19","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.jcin.2013.02.007","article-title":"Renal function-based contrast dosing predicts acute kidney injury following transcatheter aortic valve implantation.","volume":"6","author":"Yamamoto M.","year":"2013","journal-title":"JACC Cardiovasc Interv."},{"key":"key-20171220194044-20","doi-asserted-by":"publisher","first-page":"1595","DOI":"10.1016\/j.jcin.2015.07.012","article-title":"Acute Kidney Injury With the RenalGuard System in Patients Undergoing Transcatheter Aortic Valve Replacement: The PROTECT-TAVI Trial (PROphylactic effecT of furosEmide-induCed diuresis with matched isotonic intravenous hydraTion in Transcatheter Aortic Valve Implantation).","volume":"8","author":"Barbanti M.","year":"2015","journal-title":"JACC Cardiovasc Interv."},{"key":"key-20171220194044-21","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1016\/j.carrev.2017.02.011","article-title":"The ratio of contrast volume to glomerular filtration rate predicts acute kidney injury and mortality after transcatheter aortic valve implantation.","volume":"18","author":"Giannini F.","year":"2017","journal-title":"Cardiovasc Revasc Med."},{"key":"key-20171220194044-22","doi-asserted-by":"publisher","first-page":"890","DOI":"10.4244\/EIJY16M06_01","article-title":"Current status of transcatheter valve therapy in Europe: results from an EAPCI survey.","volume":"12","author":"Petronio AS.","year":"2016","journal-title":"EuroIntervention."},{"key":"key-20171220194044-23","article-title":"How to plan an Overlap Free Projection on CTA or fluoroscopy to facilitate quantitative analysis.","volume":"Epub AOP","author":"Teng J.","year":"2017 June 13","journal-title":"EuroIntervention."}],"container-title":["EuroIntervention"],"original-title":[],"deposited":{"date-parts":[[2017,12,21]],"date-time":"2017-12-21T07:23:50Z","timestamp":1513841030000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.pcronline.com\/eurointervention\/126th_issue\/204"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,12]]},"references-count":24,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2017,12]]}},"alternative-id":["EIJ-D-17-00355"],"URL":"https:\/\/doi.org\/10.4244\/eij-d-17-00355","relation":{},"ISSN":["1774-024X"],"issn-type":[{"value":"1774-024X","type":"print"}],"subject":[],"published":{"date-parts":[[2017,12]]}}}