{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T05:12:18Z","timestamp":1774674738671,"version":"3.50.1"},"reference-count":42,"publisher":"Europa Digital & Publishing","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["EuroIntervention"],"published-print":{"date-parts":[[2009,3]]},"DOI":"10.4244\/eijv4i5a111","type":"journal-article","created":{"date-parts":[[2010,8,24]],"date-time":"2010-08-24T18:02:11Z","timestamp":1282672931000},"page":"669-675","source":"Crossref","is-referenced-by-count":11,"title":["The use of self-expanding stents in coronary bifurcations and beyond: a paradigm revisited"],"prefix":"10.4244","volume":"4","author":[{"given":"Hasan","family":"Jilaihawi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruno","family":"Farah","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jean-Claude","family":"Laborde","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2774","reference":[{"key":"key-201082213158-0","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1002\/(SICI)1522-726X(200003)49:3<274::AID-CCD11>3.0.CO;2-N","article-title":"Stenting of bifurcation lesions: classification, treatments, and results.","volume":"49","author":"Lef\u00e8vre T","year":"2000","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-1","doi-asserted-by":"crossref","first-page":"1244","DOI":"10.1161\/01.CIR.0000118474.71662.E3","article-title":"Randomized study to evaluate sirolimus-eluting stents implanted at coronary bifurcation lesions.","volume":"109","author":"Colombo A","year":"2004","journal-title":"Circulation"},{"key":"key-201082213158-2","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1136\/hrt.2005.061531","article-title":"Treatment of bifurcation lesions with two stents: one year angiographic and clinical follow up of crush versus T stenting.","volume":"92","author":"Ge L","year":"2006","journal-title":"Heart"},{"key":"key-201082213158-3","doi-asserted-by":"crossref","first-page":"1949","DOI":"10.1016\/j.jacc.2005.11.083","article-title":"Long-term outcomes after stenting of bifurcation lesions with the \"crush\" technique: predictors of an adverse outcome.","volume":"47","author":"Hoye A","year":"2006","journal-title":"J Am Coll Cardiol."},{"key":"key-201082213158-4","doi-asserted-by":"crossref","first-page":"1214","DOI":"10.1016\/j.amjcard.2006.05.051","article-title":"Acute and long-term results of bifurcation stenting (from the Coroflex Registry).","volume":"98","author":"Rux S","year":"2006","journal-title":"Am J Cardiol."},{"key":"key-201082213158-5","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1002\/ccd.20556","article-title":"Acute and long-term outcomes of the novel side access (SLK-View) stent for bifurcation coronary lesions: a multicenter nonrandomized feasibility study.","volume":"67","author":"Ikeno F","year":"2006","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-6","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1016\/j.jacc.2005.05.033","article-title":"The Frontier stent registry: safety and feasibility of a novel dedicated stent for the treatment of bifurcation coronary artery lesions.","volume":"46","author":"Lef\u00e8vre T","year":"2005","journal-title":"J Am Coll Cardiol."},{"key":"key-201082213158-7","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1002\/ccd.21206","article-title":"The AST petal dedicated bifurcation stent: first-in-human experience.","volume":"70","author":"Ormiston J","year":"2007","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-8","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.1161\/CIRCULATIONAHA.106.664920","article-title":"Randomized study on simple versus complex stenting of coronary artery bifurcation lesions: the Nordic bifurcation study.","volume":"114","author":"Steigen TK","year":"2006","journal-title":"Circulation"},{"key":"key-201082213158-9","article-title":"Eight months angiographic follow-up in patients randomized to crush or culotte bifurcation stenting: the Nordic Stent Technique Study.","author":"Gunnes P","year":"2008","journal-title":"American College of Cardiology"},{"key":"key-201082213158-10","doi-asserted-by":"crossref","first-page":"546","DOI":"10.4244\/EIJV3I5A99","article-title":"Tryton I, First-In-Man (FIM) study: six month clinical and angiographic outcome, analysis with new quantitative coronary angiography dedicated for bifurcation lesions.","volume":"3","author":"Onuma Y","year":"2008","journal-title":"EuroIntervention"},{"key":"key-201082213158-11","article-title":"Minvasys-Nile PAX: the true dedicated bifurcation abluminal polymer free drug-eluting stent.","author":"Martin I.","year":"2008","journal-title":"EuroPCR"},{"key":"key-201082213158-12","first-page":"604","article-title":"Conformity of carotid stents with vascular anatomy: evaluation in carotid models.","volume":"25","author":"Tanaka N","year":"2004","journal-title":"AJNR Am J Neuroradiol."},{"key":"key-201082213158-13","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1007\/s00270-005-0137-6","article-title":"Long-term histopathologic and IVUS evaluations of a novel coiled sheet stent in porcine carotid arteries.","volume":"29","author":"Kaneda H","year":"2006","journal-title":"Cardiovasc Intervent Radiol."},{"key":"key-201082213158-14","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1002\/ccd.21269","article-title":"Analysis of bifurcation lesions treated with novel drug-eluting dedicated bifurcation stent system: intravascular ultrasound results of the AXXESS PLUS trial.","volume":"70","author":"Miyazawa A","year":"2007","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-15","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1002\/ccd.21096","article-title":"Bifurcation stenting with a dedicated biolimus-eluting stent: X-ray visual enhancement of the final angiographic result with \"StentBoost Subtract\".","volume":"70","author":"Agostoni P","year":"2007","journal-title":"Cathet Cardiovasc Intervent"},{"key":"key-201082213158-16","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1016\/j.amjcard.2007.01.043","article-title":"Six-month clinical and angiographic results of a dedicated drug-eluting stent for thetreatment of coronary bifurcation narrowings.","volume":"99","author":"Grube E","year":"2007","journal-title":"Am J Cardiol."},{"key":"key-201082213158-17","journal-title":"http:\/\/www.tctmd.com\/txshow.aspx?tid=2628&id=70670&trid=292"},{"key":"key-201082213158-18","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1002\/ccd.21765","article-title":"Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial.","volume":"73","author":"Hasegawa T","year":"2009","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-19","first-page":"162","article-title":"Stentys coronary bifurcation stent.","volume":"3","author":"Laborde JC","year":"2007","journal-title":"EuroIntervention"},{"key":"key-201082213158-20","article-title":"Novel self-expanding stent system for enhanced provisional bifurcation stenting: examination by StentBoost and intravascular ultrasound.","volume":"Epub AOP","author":"Agostoni P","year":"2008","journal-title":"Cathet Cardiovasc Intervent"},{"key":"key-201082213158-21","author":"Grube E.","year":"2007","journal-title":"Cardiovascular Revascularisation Therapies Meeting, Washington DC"},{"key":"key-201082213158-22","first-page":"26","article-title":"The Sideguard(tm) Ostium Protection Device: The next generation in bifurcation stenting","volume":"14","author":"Paquin M.","year":"2006","journal-title":"Cath Lab Digest"},{"key":"key-201082213158-23","author":"Mauri L.","year":"2007","journal-title":"Cardiovascular Revascularisation Therapies Meeting, Washington DC"},{"key":"key-201082213158-24","first-page":"154","article-title":"\"The CardioMind coronary stent delivery system: stent delivery on a 0.014\"\" wire.\"","volume":"3","author":"Abizaid A","year":"2007","journal-title":"EuroIntervention"},{"key":"key-201082213158-25","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1002\/ccd.21562","article-title":"Novel guidewire-based stent delivery system: Examination by intravascular ultrasound.","volume":"72","author":"Yamasaki M","year":"2008","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-26","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1002\/ccd.21817","article-title":"Step-by-step StentBoost-guided small vessel stenting using the self-expandable sparrow stent-in-wire.","volume":"73","author":"Agostoni P","year":"2009","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-27","author":"Granada J","year":"2007","journal-title":"Transcatheter Cardiovascular Therapeutics Meeting, Washington DC"},{"key":"key-201082213158-28","doi-asserted-by":"crossref","first-page":"416","DOI":"10.4244\/EIJV3I3A73","article-title":"vProtectTM luminal shield system.","volume":"3","author":"Granada J","year":"2007","journal-title":"EuroIntervention"},{"key":"key-201082213158-29","doi-asserted-by":"crossref","first-page":"635","DOI":"10.4244\/EIJV3I5A113","article-title":"The vPredictTM Optical Catheter System: Intravascular Raman Spectroscopy.","volume":"3","author":"Brennan J","year":"2008","journal-title":"EuroIntervention"},{"key":"key-201082213158-30","doi-asserted-by":"crossref","first-page":"235","DOI":"10.3109\/13645700009169654","article-title":"An overview of superelastic stent design.","volume":"9","author":"T.W. Duerig T","year":"2000","journal-title":"Min Invas Ther & Allied Technol"},{"key":"key-201082213158-31","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1038\/scientificamerican1179-74","article-title":"Shape-memory alloys.","volume":"241","author":"Schotky LM.","year":"1979","journal-title":"Sci Am."},{"key":"key-201082213158-32","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1148\/radiology.156.1.3159043","article-title":"Expandable intraluminal graft: a preliminary study: work in progress.","volume":"156","author":"Palmaz JC","year":"1985","journal-title":"Radiology"},{"key":"key-201082213158-33","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1161\/01.CIR.76.2.450","article-title":"Balloon-expandable intracoronary stents in the adult dog.","volume":"76","author":"Schatz RA","year":"1987","journal-title":"Circulation"},{"key":"key-201082213158-34","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1056\/NEJMra051091","article-title":"Coronary-artery stents.","volume":"354","author":"Serruys PW","year":"2006","journal-title":"N Engl J Med."},{"key":"key-201082213158-35","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1056\/NEJM198703193161201","article-title":"Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty.","volume":"316","author":"Sigwart U","year":"1987","journal-title":"N Engl J Med"},{"key":"key-201082213158-36","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1056\/NEJM199101033240103","article-title":"Angiographic follow-up after placement of a self-expanding coronary-artery stent.","volume":"324","author":"Serruys PW","year":"1991","journal-title":"N Engl J Med."},{"key":"key-201082213158-37","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1002\/(SICI)1522-726X(200004)49:4<401::AID-CCD11>3.0.CO;2-4","article-title":"Angiographic and clinical outcome of a new self-expanding intracoronary stent (RADIUS): results from multicenter experience in Japan.","volume":"49","author":"Hirayama A","year":"2000","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-201082213158-38","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1016\/S0002-9149(01)01636-8","article-title":"Comparison of self-expanding and balloon-expandable stents for the reduction of restenosis.","volume":"88","author":"Han RO","year":"2001","journal-title":"Am J Cardiol."},{"key":"key-201082213158-39","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1016\/S0735-1097(01)01162-7","article-title":"Long-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE Trial.A Stent vs. Stent Ultrasound Remodeling Evaluation.","volume":"37","author":"Kobayashi Y","year":"2001","journal-title":"J Am Coll Cardiol."},{"key":"key-201082213158-40","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00380-007-1000-2","article-title":"Prospective randomized trial comparing a nitinol self-expanding coronary stent with low-pressure dilatation and a high-pressure balloon expandable bare metal stent.","volume":"23","author":"Tanaka S","year":"2008","journal-title":"Heart Vessels"},{"key":"key-201082213158-41","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1002\/ccd.10249","article-title":"Stent design-related coronary artery remodeling and patterns of neointima formation following self-expanding and balloon-expandable stent implantation.","volume":"56","author":"Konig A","year":"2002","journal-title":"Catheter Cardiovasc Interv."}],"container-title":["EuroIntervention"],"original-title":[],"deposited":{"date-parts":[[2024,3,29]],"date-time":"2024-03-29T21:24:24Z","timestamp":1711747464000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.pcronline.com\/eurointervention\/18th_issue\/111"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,3]]},"references-count":42,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2009,3]]}},"alternative-id":["EIJV4I5A111"],"URL":"https:\/\/doi.org\/10.4244\/eijv4i5a111","relation":{},"ISSN":["1774-024X"],"issn-type":[{"value":"1774-024X","type":"print"}],"subject":[],"published":{"date-parts":[[2009,3]]}}}