{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,30]],"date-time":"2026-08-30T01:42:59Z","timestamp":1788054179725,"version":"build-2784847793"},"reference-count":26,"publisher":"Europa Digital & Publishing","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["EuroIntervention"],"published-print":{"date-parts":[[2014,4]]},"DOI":"10.4244\/eijv9i12a237","type":"journal-article","created":{"date-parts":[[2014,4,23]],"date-time":"2014-04-23T08:22:56Z","timestamp":1398241376000},"page":"1398-1406","source":"Crossref","is-referenced-by-count":20,"title":["Incidence, predictive factors and haemodynamic consequences of acute stent recoil following transcatheter aortic valve implantation with a balloon-expandable valve"],"prefix":"10.4244","volume":"9","author":[{"given":"Luis","family":"Nombela-Franco","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henrique B.","family":"Ribeiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marina","family":"Urena","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergio","family":"Pasian","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ricardo","family":"Allende","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Doyle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"DeLarochelli\u00e8re","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hugo","family":"DeLarochelli\u00e8re","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Louis","family":"Laflamme","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jer\u00f4me","family":"Laflamme","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miguel","family":"Jerez-Valero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melanie","family":"C\u00f4t\u00e9","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Pibarot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Larose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric","family":"Dumont","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josep","family":"Rod\u00e9s-Cabau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2774","reference":[{"key":"key-2014416164324-0","doi-asserted-by":"publisher","first-page":"34B","DOI":"10.1016\/0735-1097(91)90936-4","article-title":"Regional differences in elastic recoil after percutaneous transluminal coronary angioplasty: a quantitative angiographic study.","volume":"17","author":"Rensing B","year":"1991","journal-title":"J Am Coll Cardiol."},{"key":"key-2014416164324-1","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1161\/01.CIR.98.2.112","article-title":"Mechanisms of residual lumen stenosis after high-pressure stent implantation: a quantitative coronary angiography and intravascular ultrasound study.","volume":"98","author":"Bermejo J","year":"1998","journal-title":"Circulation."},{"key":"key-2014416164324-2","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1016\/0002-9149(93)90856-8","article-title":"Clinical and angiographic predictors of immediate recoil after successful coronary angioplasty and relation to late restenosis.","volume":"72","author":"Rozenman Y","year":"1993","journal-title":"Am J Cardiol."},{"key":"key-2014416164324-3","doi-asserted-by":"publisher","first-page":"1428","DOI":"10.1016\/S0735-1097(97)00334-3","article-title":"Predictive factors of restenosis after coronary stent placement.","volume":"30","author":"Kastrati A","year":"1997","journal-title":"J Am Coll Cardiol."},{"key":"key-2014416164324-4","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1161\/01.CIR.100.7.756","article-title":"In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: differential outcome by stent design.","volume":"100","author":"Carrozza J","year":"1999","journal-title":"Circulation."},{"key":"key-2014416164324-5","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1002\/(SICI)1522-726X(199906)47:2<251::AID-CCD26>3.0.CO;2-M","article-title":"Effect of stent design on reduction of elastic recoil: a comparison via quantitative intravascular ultrasound.","volume":"47","author":"Yamamoto Y","year":"1999","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-2014416164324-6","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1038\/nrcardio.2011.164","article-title":"Transcatheter aortic valve implantation: current and future approaches.","volume":"9","author":"Rod\u00e9s-Cabau J.","year":"2011","journal-title":"Nat Rev Cardiol."},{"key":"key-2014416164324-7","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.1016\/j.jcmg.2011.06.021","article-title":"Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography.","volume":"4","author":"Clavel M","year":"2011","journal-title":"JACC Cardiovasc Imaging."},{"key":"key-2014416164324-8","first-page":"223","article-title":"European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1: aortic and pulmonary regurgitation (native valve disease).","volume":"11","author":"Lancelloti P","year":"2010","journal-title":"Eur Heart J."},{"key":"key-2014416164324-9","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1016\/j.echo.2009.07.013","article-title":"Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound.","volume":"22","author":"Zoghbi W","year":"2009","journal-title":"J Am Soc Echocardiogr."},{"key":"key-2014416164324-10","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1016\/0735-1097(90)90282-T","article-title":"Quantification of coronary artery calcium using ultrafast computed tomography.","volume":"15","author":"Agatston A","year":"1990","journal-title":"J Am Coll Cardiol."},{"key":"key-2014416164324-11","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.jcct.2012.11.002","article-title":"SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)\/transcatheter aortic valve replacement (TAVR).","volume":"6","author":"Achenbach S","year":"2012","journal-title":"J Cardiovasc Comput Tomogr."},{"key":"key-2014416164324-12","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1016\/j.jacc.2009.04.075","article-title":"Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis.","volume":"54","author":"Schultz C","year":"2009","journal-title":"J Am Coll Cardiol."},{"key":"key-2014416164324-13","doi-asserted-by":"publisher","first-page":"1830","DOI":"10.1016\/j.amjcard.2011.02.317","article-title":"Comparison of complete versus incomplete stent frame expansion after transcatheter aortic valve implantation with Medtronic CoreValve bioprosthesis.","volume":"107","author":"Jilaihawi H","year":"2011","journal-title":"Am J Cardiol."},{"key":"key-2014416164324-14","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.medengphy.2012.04.009","article-title":"Numerical analysis of the radial force produced by the Medtronic-CoreValve and Edwards-SAPIEN after transcatheter aortic valve implantation (TAVI).","volume":"35","author":"Tzamtzis S","year":"2013","journal-title":"Med Eng Phys."},{"key":"key-2014416164324-15","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.1136\/hrt.2006.107052","article-title":"Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size.","volume":"93","author":"Aziz S","year":"2007","journal-title":"Heart."},{"key":"key-2014416164324-16","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1002\/1522-726X(200102)52:2<147::AID-CCD1038>3.0.CO;2-B","article-title":"Acute stent recoil: in vivo evaluation of different stent designs.","volume":"52","author":"Danzi G","year":"2001","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-2014416164324-17","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1002\/(SICI)1522-726X(200005)50:1<112::AID-CCD25>3.0.CO;2-X","article-title":"Elastic recoil of coronary stents: a comparative analysis.","volume":"50","author":"Barragan P","year":"2000","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-2014416164324-18","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1161\/01.CIR.100.7.756","article-title":"In vivo assessment of stent expansion and recoil in normal porcine coronary arteries: differential outcome by stent design.","volume":"100","author":"Carrozza J","year":"1999","journal-title":"Circulation."},{"key":"key-2014416164324-19","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1007\/s12325-010-0022-9","article-title":"The platinum chromium element stent platform: from alloy, to design, to clinical practice.","volume":"27","author":"Menown I","year":"2010","journal-title":"Adv Ther."},{"key":"key-2014416164324-20","doi-asserted-by":"publisher","first-page":"3M","DOI":"10.1016\/j.amjcard.2007.08.016","article-title":"Design criteria for the ideal drug-eluting stent.","volume":"100","author":"Ako J","year":"2007","journal-title":"Am J Cardiol."},{"key":"key-2014416164324-21","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1016\/0002-9149(90)90501-Q","article-title":"Quantitative angiographic assessment of elastic recoil after percutaneous transluminal coronary angioplasty.","volume":"66","author":"Rensing B","year":"1990","journal-title":"Am J Cardiol."},{"key":"key-2014416164324-22","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1007\/s10439-012-0694-1","article-title":"Quantification of biomechanical interaction of transcatheter aortic valve stent deployed in porcine and ovine hearts.","volume":"41","author":"Mummert J","year":"2013","journal-title":"Ann Biomed Eng."},{"key":"key-2014416164324-23","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.1016\/j.amjcard.2011.07.007","article-title":"Location and severity of aortic valve calcium and implications for aortic regurgitation after transcatheter aortic valve implantation.","volume":"108","author":"Ewe S","year":"2011","journal-title":"Am J Cardiol."},{"key":"key-2014416164324-24","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1002\/ccd.23003","article-title":"Predictors of moderate to severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation.","volume":"78","author":"Takagi K","year":"2011","journal-title":"Catheter Cardiovasc Interv."},{"key":"key-2014416164324-25","doi-asserted-by":"publisher","first-page":"1114","DOI":"10.1093\/eurheartj\/ehq018","article-title":"Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function.","volume":"31","author":"Delgado V","year":"2010","journal-title":"Eur Heart J."}],"container-title":["EuroIntervention"],"original-title":[],"deposited":{"date-parts":[[2024,5,26]],"date-time":"2024-05-26T04:28:42Z","timestamp":1716697722000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.pcronline.com\/eurointervention\/71st_issue\/237"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,4]]},"references-count":26,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2014,4]]}},"alternative-id":["20130106-04"],"URL":"https:\/\/doi.org\/10.4244\/eijv9i12a237","relation":{},"ISSN":["1774-024X"],"issn-type":[{"value":"1774-024X","type":"print"}],"subject":[],"published":{"date-parts":[[2014,4]]}}}