{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T10:19:14Z","timestamp":1760955554834},"reference-count":17,"publisher":"Europa Digital & Publishing","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["EuroIntervention"],"published-print":{"date-parts":[[2015,8]]},"DOI":"10.4244\/eijy14m06_08","type":"journal-article","created":{"date-parts":[[2015,9,6]],"date-time":"2015-09-06T10:24:42Z","timestamp":1441535082000},"page":"442-449","source":"Crossref","is-referenced-by-count":15,"title":["Rotational angiography with motion compensation: first-in-man use for the 3D evaluation of transcatheter valve prostheses"],"prefix":"10.4244","volume":"11","author":[{"given":"Carl J.","family":"Schultz","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guenter","family":"Lauritsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicholas","family":"Van Mieghem","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher","family":"Rohkohl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick W.","family":"Serruys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert Jan","family":"van Geuns","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter P.T.","family":"de Jaegere","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2774","reference":[{"key":"key-2015961148-0","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.1056\/NEJMoa1008232","article-title":"Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery.","volume":"363","author":"Leon MB.","year":"2010","journal-title":"N Engl J Med."},{"key":"key-2015961148-1","first-page":"531","article-title":"Age-stratified baseline and outcome characteristics of patients undergoing transcatheter aortic valve implantation: results from the German multicenter registry.","volume":"24","author":"Buellesfeld L.","year":"2012","journal-title":"J Invasive Cardiol."},{"key":"key-2015961148-2","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1093\/ejcts\/ezr244","article-title":"Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation.","volume":"41","author":"Haensig M.","year":"2012","journal-title":"Eur J Cardiothorac Surg."},{"key":"key-2015961148-3","doi-asserted-by":"publisher","first-page":"564","DOI":"10.4244\/EIJV7I5A92","article-title":"Aortic annulus dimensions and leaflet calcification from contrast MSCT predict the need for balloon post-dilatation after TAVI with the Medtronic CoreValve prosthesis.","volume":"7","author":"Schultz C.","year":"2011","journal-title":"EuroIntervention."},{"key":"key-2015961148-4","first-page":"132","article-title":"Interventional 4-D motion estimation and reconstruction of cardiac vasculature without motion periodicity assumption.","volume":"12","author":"Rohkohl C.","year":"2009","journal-title":"Med Image Comput Comput Assist Interv."},{"key":"key-2015961148-5","first-page":"151","article-title":"ECG-gated interventional cardiac reconstruction for non-periodic motion.","volume":"13","author":"Rohkohl C.","year":"2010","journal-title":"Med Image Comput Comput Assist Interv."},{"key":"key-2015961148-6","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1093\/eurheartj\/ehp534","article-title":"Three-dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer\u2019s guidelines for sizing for percutaneous aortic valve replacement helpful?","volume":"31","author":"Schultz CJ.","year":"2010","journal-title":"Eur Heart J."},{"key":"key-2015961148-7","doi-asserted-by":"publisher","first-page":"911","DOI":"10.1016\/j.jacc.2009.04.075","article-title":"Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis.","volume":"54","author":"Schultz CJ.","year":"2009","journal-title":"J Am Coll Cardiol."},{"key":"key-2015961148-8","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/0002-9149(64)90027-X","article-title":"Left retrograde cardioangiography in acquired cardiac disease: technic, indications and interpretations in 700 cases.","volume":"14","author":"Sellers RD.","year":"1964","journal-title":"Am J Cardiol."},{"key":"key-2015961148-9","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1093\/ehjci\/jet037","article-title":"Effect of body mass index on the image quality of rotational angiography without rapid pacing for planning of transcatheter aortic valve implantation: a comparison with multislice computed tomography.","volume":"15","author":"Schultz CJ.","year":"2014","journal-title":"Eur Heart J Cardiovasc Imaging."},{"key":"key-2015961148-10","doi-asserted-by":"publisher","first-page":"1830","DOI":"10.1016\/j.amjcard.2011.02.317","article-title":"Comparison of complete versus incomplete stent frame expansion after transcatheter aortic valve implantation with Medtronic CoreValve bioprosthesis.","volume":"107","author":"Jilaihawi H.","year":"2011","journal-title":"Am J Cardiol."},{"key":"key-2015961148-11","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1016\/j.jcin.2012.05.014","article-title":"Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement.","volume":"5","author":"Blanke P.","year":"2012","journal-title":"JACC Cardiovasc Interv."},{"key":"key-2015961148-12","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1016\/j.athoracsur.2011.08.068","article-title":"Pulsatile distention of the nondiseased and stenotic aortic valve annulus: analysis with electrocardiogram-gated computed tomography.","volume":"93","author":"de Heer LM.","year":"2012","journal-title":"Ann Thorac Surg."},{"key":"key-2015961148-13","doi-asserted-by":"publisher","first-page":"750","DOI":"10.1016\/j.ejcts.2010.03.039","article-title":"Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method.","volume":"38","author":"Blanke P.","year":"2010","journal-title":"Eur J Cardiothorac Surg."},{"key":"key-2015961148-14","doi-asserted-by":"publisher","first-page":"3085","DOI":"10.1016\/j.jbiomech.2010.08.010","article-title":"Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.","volume":"43","author":"Sun W.","year":"2010","journal-title":"J Biomech."},{"key":"key-2015961148-15","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1016\/j.jacc.2010.06.035","article-title":"Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis.","volume":"56","author":"Sherif MA.","year":"2010","journal-title":"J Am Coll Cardiol."},{"key":"key-2015961148-16","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1002\/ccd.23003","article-title":"Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation.","volume":"78","author":"Takagi K.","year":"2011","journal-title":"Catheter Cardiovasc Interv."}],"container-title":["EuroIntervention"],"original-title":[],"deposited":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T23:40:59Z","timestamp":1718062859000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.pcronline.com\/eurointervention\/87th_issue\/89"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,8]]},"references-count":17,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2015,8]]}},"alternative-id":["20140130-01"],"URL":"https:\/\/doi.org\/10.4244\/eijy14m06_08","relation":{},"ISSN":["1774-024X"],"issn-type":[{"value":"1774-024X","type":"print"}],"subject":[],"published":{"date-parts":[[2015,8]]}}}