{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,30]],"date-time":"2025-10-30T22:30:39Z","timestamp":1761863439543},"reference-count":30,"publisher":"Europa Digital & Publishing","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["EuroIntervention"],"published-print":{"date-parts":[[2015,6]]},"DOI":"10.4244\/eijy15m03_01","type":"journal-article","created":{"date-parts":[[2015,7,12]],"date-time":"2015-07-12T13:20:42Z","timestamp":1436707242000},"page":"238-246","source":"Crossref","is-referenced-by-count":18,"title":["Proximal occlusion versus distal filter for cerebral protection during carotid stenting: updated meta-analysis of randomised and observational MRI studies"],"prefix":"10.4244","volume":"11","author":[{"given":"Salvatore","family":"Cassese","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gjin","family":"Ndrepepa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lamin A.","family":"King","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mateja","family":"Nerad","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Heribert","family":"Schunkert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Adnan","family":"Kastrati","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ilka","family":"Ott","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Massimiliano","family":"Fusaro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2774","reference":[{"key":"key-2015712145930-0","doi-asserted-by":"publisher","first-page":"2851","DOI":"10.1093\/eurheartj\/ehr211","article-title":"ESC Guidelines on the diagnosis and treatment of peripheral artery diseases: Document covering atherosclerotic disease of extracranial carotid and vertebral, mesenteric, renal, upper and lower extremity arteries: the Task Force on the Diagnosis and Treatment of Peripheral Artery Diseases of the European Society of Cardiology (ESC).","volume":"32","author":"Tendera M.","year":"2011","journal-title":"Eur Heart J."},{"key":"key-2015712145930-1","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1161\/CIR.0b013e31820d8d78","article-title":"2011 ASA\/ACCF\/AHA\/AANN\/AANS\/ACR\/ASNR\/CNS\/SAIP\/SCAI\/SIR\/SNIS\/SVM\/SVS guideline on the management of patients with extracranial carotid and vertebral artery disease: executive summary.","volume":"124","author":"Brott TG.","year":"2011","journal-title":"Circulation."},{"key":"key-2015712145930-2","doi-asserted-by":"publisher","first-page":"1966","DOI":"10.1016\/j.jacc.2004.08.049","article-title":"Effect of two different neuroprotection systems on microembolization during carotid artery stenting.","volume":"44","author":"Schmidt A.","year":"2004","journal-title":"J Am Coll Cardiol."},{"key":"key-2015712145930-3","doi-asserted-by":"publisher","first-page":"1656","DOI":"10.1016\/j.jacc.2011.07.015","article-title":"Microembolization during carotid artery stenting in patients with high-risk, lipid-rich plaque. A randomized trial of proximal versus distal cerebral protection.","volume":"58","author":"Montorsi P.","year":"2011","journal-title":"J Am Coll Cardiol."},{"key":"key-2015712145930-4","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.jcin.2012.10.019","article-title":"Impact of asymptomatic cerebral lesions in diffusion-weighted magnetic resonance imaging after carotid artery stenting.","volume":"6","author":"Bijuklic K.","year":"2013","journal-title":"JACC Cardiovasc Interv."},{"key":"key-2015712145930-5","doi-asserted-by":"publisher","first-page":"1429","DOI":"10.1016\/j.jvs.2012.05.077","article-title":"Current update of cerebral embolic protection devices.","volume":"56","author":"Mousa AY.","year":"2012","journal-title":"J Vasc Surg."},{"key":"key-2015712145930-6","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1016\/j.jacc.2009.11.079","article-title":"Proximal endovascular occlusion for carotid artery stenting: results from a prospective registry of 1,300 patients.","volume":"55","author":"Stabile E.","year":"2010","journal-title":"J Am Coll Cardiol."},{"key":"key-2015712145930-7","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1583\/06-1990.1","article-title":"Periprocedural embolic events related to carotid artery stenting detected by diffusion-weighted MRI: comparison between proximal and distal embolus protection devices.","volume":"14","author":"El-Koussy M.","year":"2007","journal-title":"J Endovasc Ther."},{"key":"key-2015712145930-8","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1016\/j.jacc.2011.11.035","article-title":"The PROFI study (Prevention of Cerebral Embolization by Proximal Balloon Occlusion Compared to Filter Protection During Carotid Artery Stenting): a prospective randomized trial.","volume":"59","author":"Bijuklic K.","year":"2012","journal-title":"J Am Coll Cardiol."},{"key":"key-2015712145930-9","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1161\/CIRCINTERVENTIONS.113.000479","article-title":"Flow reversal versus filter protection: a pilot carotid artery stenting randomized trial.","volume":"6","author":"Castro-Afonso LH.","year":"2013","journal-title":"Circ Cardiovasc Interv."},{"key":"key-2015712145930-10","doi-asserted-by":"publisher","first-page":"478","DOI":"10.1016\/j.ijcard.2014.07.241","article-title":"Cerebral microemboli and neurocognitive change after carotid artery stenting with different embolic protection devices.","volume":"176","author":"Akkaya E.","year":"2014","journal-title":"Int J Cardiol."},{"key":"key-2015712145930-11","doi-asserted-by":"publisher","first-page":"264","DOI":"10.7326\/0003-4819-151-4-200908180-00135","article-title":"Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement.","volume":"151","author":"Moher D.","year":"2009","journal-title":"Ann Intern Med."},{"key":"key-2015712145930-12","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses.","volume":"327","author":"Higgins JP.","year":"2003","journal-title":"BMJ."},{"key":"key-2015712145930-13","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1001\/jama.282.11.1054","article-title":"The hazards of scoring the quality of clinical trials for meta-analysis.","volume":"282","author":"J\u00fcni P.","year":"1999","journal-title":"JAMA."},{"key":"key-2015712145930-14","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1161\/CIRCINTERVENTIONS.112.969972","article-title":"Paclitaxel-coated versus uncoated balloon angioplasty reduces target lesion revascularization in patients with femoropopliteal arterial disease: a meta-analysis of randomized trials.","volume":"5","author":"Cassese S.","year":"2012","journal-title":"Circ Cardiovasc Interv."},{"key":"key-2015712145930-15","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1136\/bmj.323.7304.101","article-title":"Systematic reviews in health care: Investigating and dealing with publication and other biases in meta-analysis.","volume":"323","author":"Sterne JA.","year":"2001","journal-title":"BMJ."},{"key":"key-2015712145930-16","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1016\/j.jcin.2013.07.006","article-title":"Randomized comparison of distal and proximal cerebral protection during carotid artery stenting.","volume":"6","author":"Cano MN.","year":"2013","journal-title":"JACC Cardiovasc Interv."},{"key":"key-2015712145930-17","doi-asserted-by":"publisher","first-page":"243","DOI":"10.4244\/EIJV3I2A42","article-title":"Diffusion-weighted imaging to compare different cerebral protection devices in carotid artery stenting.","volume":"3","author":"Flach ZH.","year":"2007","journal-title":"EuroIntervention."},{"key":"key-2015712145930-18","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1097\/00001648-200005000-00005","article-title":"An exact method for meta-analysis of case-control and follow-up studies.","volume":"11","author":"Martin DO.","year":"2000","journal-title":"Epidemiology."},{"key":"key-2015712145930-19","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1161\/01.cir.0000442015.53336.12","article-title":"American Heart Association Statistics Committee and Stroke Statistics Subcommittee. Executive summary: heart disease and stroke statistics--2014 update: a report from the American Heart Association.","volume":"129","author":"Go AS.","year":"2014","journal-title":"Circulation."},{"key":"key-2015712145930-20","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1056\/NEJMoa0912321","article-title":"Stenting versus endarterectomy for treatment of carotid-artery stenosis.","volume":"363","author":"Brott TG.","year":"2010","journal-title":"N Engl J Med."},{"key":"key-2015712145930-21","doi-asserted-by":"publisher","first-page":"171","DOI":"10.1016\/j.jcin.2013.10.014","article-title":"Comparative effectiveness of commonly used devices for carotid artery stenting: an NCDR (National Cardiovascular Data Registry) analysis.","volume":"7","author":"Giri J.","year":"2014","journal-title":"JACC Cardiovasc Interv."},{"key":"key-2015712145930-22","doi-asserted-by":"publisher","first-page":"1614","DOI":"10.1016\/j.jacc.2012.06.037","article-title":"The problem with asymptomatic cerebral embolic complications in vascular procedures: what if they are not asymptomatic?","volume":"60","author":"Gress DR.","year":"2012","journal-title":"J Am Coll Cardiol."},{"key":"key-2015712145930-23","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.jns.2013.02.019","article-title":"Diffusion-weighted lesions after carotid artery stenting are associated with cognitive impairment.","volume":"328","author":"Maggio P.","year":"2013","journal-title":"J Neurol Sci."},{"key":"key-2015712145930-24","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1016\/j.jvs.2012.05.092","article-title":"Prospective neurocognitive evaluation of patients undergoing carotid interventions.","volume":"56","author":"Zhou W.","year":"2012","journal-title":"J Vasc Surg."},{"key":"key-2015712145930-25","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1161\/CIRCULATIONAHA.112.000701","article-title":"Fixing hearts and protecting minds: a review of the multiple, interacting factors influencing cognitive function after coronary artery bypass graft surgery.","volume":"128","author":"Hogan AM.","year":"2013","journal-title":"Circulation."},{"key":"key-2015712145930-26","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1161\/CIRCINTERVENTIONS.112.000093","article-title":"Risk factors for cerebral embolization after carotid artery stenting with embolic protection: a diffusion-weighted magnetic resonance imaging study in 837 consecutive patients.","volume":"6","author":"Bijuklic K.","year":"2013","journal-title":"Circ Cardiovasc Interv."},{"key":"key-2015712145930-27","doi-asserted-by":"publisher","first-page":"1845","DOI":"10.1001\/jama.292.15.1845","article-title":"Extracranial thrombotically active carotid plaque as a risk factor for ischemic stroke.","volume":"292","author":"Spagnoli LG.","year":"2004","journal-title":"JAMA."},{"key":"key-2015712145930-28","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1016\/j.jcin.2014.05.019","article-title":"Cerebral embolic lesions detected with diffusion-weighted magnetic resonance imaging following carotid artery stenting: a meta-analysis of 8 studies comparing filter cerebral protection and proximal balloon occlusion.","volume":"7","author":"Stabile E.","year":"2014","journal-title":"JACC Cardiovasc Interv."},{"key":"key-2015712145930-29","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1161\/STROKEAHA.113.003526","article-title":"Carotid stenting: is there an operator effect? A pooled analysis from the carotid stenting trialists\u2019 collaboration.","volume":"45","author":"Calvet D.","year":"2014","journal-title":"Stroke."}],"container-title":["EuroIntervention"],"original-title":[],"deposited":{"date-parts":[[2017,6,23]],"date-time":"2017-06-23T15:32:07Z","timestamp":1498231927000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.pcronline.com\/eurointervention\/85th_issue\/44"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,6]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,6]]}},"alternative-id":["20140520-04"],"URL":"https:\/\/doi.org\/10.4244\/eijy15m03_01","relation":{},"ISSN":["1774-024X"],"issn-type":[{"value":"1774-024X","type":"print"}],"subject":[],"published":{"date-parts":[[2015,6]]}}}