{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T02:52:44Z","timestamp":1790823164983,"version":"4.1.0"},"reference-count":61,"publisher":"The Society for Antibacterial and Antifungal Agents, Japan","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Biocontrol Sci."],"published-print":{"date-parts":[[2017]]},"DOI":"10.4265\/bio.22.1","type":"journal-article","created":{"date-parts":[[2017,3,27]],"date-time":"2017-03-27T22:07:08Z","timestamp":1490652428000},"page":"1-16","source":"Crossref","is-referenced-by-count":132,"title":["Ethylene Oxide Gas Sterilization of Medical Devices"],"prefix":"10.4265","volume":"22","author":[{"given":"HIDEHARU","family":"SHINTANI","sequence":"first","affiliation":[{"name":"Department of Science and Engineering, Chuo University"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2789","reference":[{"key":"1","unstructured":"29 CFR Part 1910, 132. <i>Occupational<\/i> <i>Safety and Health Standards. Personal Protective Equipment, General Requirements<\/i>. US Department of Labor -Occupational Safety and Health Administration, Washington, USA."},{"key":"2","unstructured":"29 CFR Part 1910, 133. <i>Occupational Safety and Health Standards. Personal Protective Equipment, Eye and Face Protection<\/i>. US Department of Labor -Occupational Safety and Health Administration, Washington, USA."},{"key":"3","unstructured":"29 CFR Part 1910, 1047. <i>Occupational Safety and Health Standards. Toxic and Hazardous Substances. Ethylene Oxide<\/i>. US Department of Labor -Occupational Safety and Health Administration, Washington, USA."},{"key":"4","unstructured":"AAMI TIR 15 2009. <i>Physical Aspect of Ethylene Oxide Sterilization<\/i>. Association for the Advancement of Medical Instrumentation, Arlington, USA."},{"key":"5","unstructured":"AAMI TIR 16 2009. <i>Microbiological Aspects of Ethylene Oxide Sterilization<\/i>. Association for the Advancement of Medical Instrumentation, Arlington, USA."},{"key":"6","unstructured":"AAMI TIR 17 2008. <i>Compatibility of Materials Subject to Sterilization<\/i>. Association for the Advancement of Medical Instrumentation, Arlington, USA."},{"key":"7","unstructured":"AAMI TIR 19\/A1 1999, AAMI TIR 17 2008. <i>Guidance for ANSI\/AAMI\/ISO 10993-7: 1995. Biological Evaluation of Medical Devices- Part 7. Ethylene Oxide Residue<\/i>. Association for the Advancement of Medical Instrumentation, Arlington, USA."},{"key":"8","unstructured":"AAMI TIR 20 2001. <i>Parametric Release for EO Sterilization<\/i>. Association for the Advancement of Medical Instrumentation, Arlington, USA."},{"key":"9","unstructured":"AAMI TIR 28 2009. <i>Product Adoption and Process Equivalency for Ethylene Oxide Sterilization<\/i>. Association for the Advancement of Medical Instrumentation, Arlington, USA."},{"key":"10","unstructured":"Aeschlimann, H (1984) <i>New CEN\/ISO Standard for Ethylene Oxide Residuals in Medical Devices<\/i>. Herentals: Griffith Micro Science."},{"key":"11","unstructured":"Alfa, M. J., DeGagne, R, Olson, N., and Hizon, R. (1998b) New low temperature sterilization technologies: microbicidal activity and clinical efficacy. In Rutala, W. A. (ed.) Disinfection, <i>Sterilization, and Antisepsis in Healthcare<\/i>, New York: Polyscience, 67-78."},{"key":"12","unstructured":"ANSI\/AAMI ST 41 (2008). <i>Ethylene Oxide Sterilization in Health Care Facilities: Safety and Effectiveness<\/i>. Association for the Advancement of Medical Instrumentation, Arlington, USA."},{"key":"13","unstructured":"Buben, I., Melichercfkovji, V, Novotn1 N., and Svitjkovj, R. (1999) Problems associated with sterilization using ethylene oxide. Residues in treated materials. <i>Cent. Europ. J. Public Health<\/i>, <b>4<\/b>, 197-202."},{"key":"14","unstructured":"Ernest, R. R. (1973) <i>Ethylene Oxide Gaseous Sterilization for Industrial Applications. Industrial Sterilization<\/i>. Amsterdam: Duke University Press."},{"key":"15","doi-asserted-by":"crossref","unstructured":"Handlos, V. (1980) Kinetics of the aeration of ethylene-oxide sterilized plastics. <i>Biomaterials<\/i>, <b>1<\/b>, 149-157.","DOI":"10.1016\/0142-9612(80)90038-1"},{"key":"16","unstructured":"ISO 10993-7 2008. <i>Biological Evaluation of Medical Devices-Part 7; Ethylene Oxide Sterilization Residuals<\/i>. International Organization for Standardization, USA."},{"key":"17","unstructured":"ISO 11135-7. <i>Sterilization of Health Care Products-Ethylene Oxide, Part 1: Requirements for Development, Validation and Routine Control of a Sterilization Process for Medical Devices<\/i>. International Organization for Standardization, USA."},{"key":"18","unstructured":"ISO 11138-1 2006. <i>Sterilization of Health Care Products-Biological Indicators. Part 1:General Requirements<\/i>. International Organization for Standardization, USA."},{"key":"19","unstructured":"ISO 11138-2 2006. <i>Sterilization of Health Care Products-Biological Indicators. Part 2: Biological Indicators for Ethylene Oxide Sterilization Processes<\/i>. International Organization for Standardization, USA."},{"key":"20","unstructured":"ISO 14161 2009. <i>Sterilization of Health Care Products-Biological Indicators.-Guidance for the Selection, Use and Interpretation of Results. <\/i>International Organization for Standardization, USA.<i> <\/i>"},{"key":"21","unstructured":"ISO 11137 (2012) Sterilization of health care products<b> <\/b>\u2013Radiation."},{"key":"22","doi-asserted-by":"crossref","unstructured":"Lucas, A. D., Merritt, K., Hitchins, V. M., Woods, T. O., McNamee, S. G., Lyle, D. B., and Brown, S. A. (2003) Residual ethylene oxide in medical devices and device material. <i>J. Biomed. Mater. Res<\/i>., <b>66B<\/b>, 548-552.","DOI":"10.1002\/jbm.b.10036"},{"key":"23","doi-asserted-by":"crossref","unstructured":"Mendes, G. C., Brandao, T. R., and Silva, C. L. (2007) Ethylene oxide sterilization of medical devices: A review. <i>Am. J. Infect. Disease<\/i>. <b>35<\/b>, 574-581.","DOI":"10.1016\/j.ajic.2006.10.014"},{"key":"24","doi-asserted-by":"crossref","unstructured":"Mendes, G. C., Brandao, T. R., and Silva, C. L. (2008) Ethylene Oxide Potential Toxicity. <i>Expert Rev. Med. Devices<\/i>, <b>5<\/b>, 323-328.","DOI":"10.1586\/17434440.5.3.323"},{"key":"25","unstructured":"Mosley, G. A., Gillis, J. R., and Krushefski, G. (2005) Evaluating the formulae for integrated lethality in ethylene oxide sterilization using six different endospores forming strains of bacteria, and comparisons of integrated lethality for ethylene oxide and steam systems. <i>PDA J. Pharm Sci. Technol<\/i>., <b>59<\/b>, 64-86."},{"key":"26","unstructured":"Mosley, G. A., Gillis, J. R., and Whitbourne, J. E. (2002) Calculating equivalent time for use in determining the lethality of EtO sterilization processes. <i>Med. Device Diagnost. Indust. News<\/i>, <b>24<\/b>, 54-63."},{"key":"27","unstructured":"Mosley, G. A., and Houghtling, C. W. (2005) Interpreting and understanding microbial data in validation of ethylene oxide sterilization processes. <i>Biomed. Instrument. Technol<\/i>., <b>39<\/b>, 466-482."},{"key":"28","unstructured":"Muzeni, R. J. (1985) Rapid gas chromatographic determination of ethylene oxide, ethylene chlorhydrin and ethylene glycol residues in rubber catheters, <i>J. Assoc. Official Anal. Chem<\/i>., <b>68<\/b>, 506-508."},{"key":"29","unstructured":"NFPA70 2008. <i>National Electric Code Handbook<\/i>. National Fire Protection Association, USA."},{"key":"30","doi-asserted-by":"crossref","unstructured":"Poothuli1, J., Shimizu, A., Day, R. R., and Dolovich, J. (1975) Anaphylaxis from the product(s) of ethylene oxide gas. <i>Ann. Internal Medicine<\/i>, <b>82<\/b>, 58-60.","DOI":"10.7326\/0003-4819-82-1-58"},{"key":"31","doi-asserted-by":"crossref","unstructured":"Ries, M. D., Weaver, K., and Beals, N. (1996) Safety and efficacy of ethylene oxide sterilized polyethylene in total knee arthroplasty. <i>Clin. Orthoped<\/i>. 159-163.","DOI":"10.1097\/00003086-199610000-00022"},{"key":"32","unstructured":"Rodriguez, A. C., Young, B., Cauck, K., Zelewski, J., Kwasnica, S., and Aguirre, S. (2001) Calculating accumulated lethality and survivorship in EtO sterilization processes. <i>Med. Dev. Diagnost. Indust. News<\/i>, <b>23<\/b>, 100-107."},{"key":"33","unstructured":"Rogers, W. (2005) <i>Sterilization of Polymer Healthcare Products<\/i>. Shrewsbury: Rapra Technology."},{"key":"34","doi-asserted-by":"crossref","unstructured":"Rutala, XV. A., Gergen, M. F., and Weber, D. J. (1998) Comparative evaluation of the sporicidal activity of new low temperature sterilization technologies: Ethylene oxide, 2 plasma sterilization systems, and liquid peracetic acid. <i>Am. J. Infect. Cont<\/i>., <b>26<\/b>, 393-398.","DOI":"10.1016\/S0196-6553(98)70034-3"},{"key":"35","doi-asserted-by":"crossref","unstructured":"<i>S<\/i>cott, H. (1982) Solubility parameter, specific molar cohesion, and the solubility of ethylene oxide in polymers. <i>Biomater<\/i>., <b>3<\/b>, 195-198.","DOI":"10.1016\/0142-9612(82)90018-7"},{"key":"36","doi-asserted-by":"crossref","unstructured":"Shintani, H., Suzuki, H., and Oba, T. (1981a) Qualitative and quantitative aspects of ethylene chlorohydrin, ethylene glycol; and the other reaction products of ethylene oxide in saline during the prolonged incubation. <i>Hygienic Scinces<\/i>, <b>27<\/b>, 285-295.","DOI":"10.1248\/jhs1956.27.285"},{"key":"37","doi-asserted-by":"crossref","unstructured":"Shintani, H., and Oba, T. (1981b) Colorimetric determination of residual ethylene oxide on medical devices. <i>Hygienic Scinces<\/i>, <b>27<\/b>, 224-230.","DOI":"10.1248\/jhs1956.27.224"},{"key":"38","doi-asserted-by":"crossref","unstructured":"Shintani, H., and Nakamura, A. (1991a) Mechanisms of degradation and crosslinking of polyurethane when irradiated by gamma-rays. <i>J. Applied Polymer Sci<\/i>., <b>42<\/b>, 1979-1987.","DOI":"10.1002\/app.1991.070420723"},{"key":"39","doi-asserted-by":"crossref","unstructured":"Shintani, H. (1991c) Degradation and cross-linking pf polyurethane irradiated by gamma-rays. <i>Polymer Degradation and Stability<\/i>, <b>32<\/b>, 191-208.","DOI":"10.1016\/0141-3910(91)90050-2"},{"key":"40","unstructured":"Shintani, H. (1992) Gamma-radiation and autoclave sterilization of thermophilic and thermosetting polyurethane. <i>J. Rad. Steril<\/i>., <b>1<\/b>, 11-28."},{"key":"41","doi-asserted-by":"crossref","unstructured":"Shintani, H., Hata, Y., and Nakamura, A. (1993) Solid phase extraction and HPLC analysis of toxic components eluted from methyl methacrylate dental materials. <i>J. Anal. Toxicol<\/i>., <b>17<\/b>, 73-78.","DOI":"10.1093\/jat\/17.2.73"},{"key":"42","unstructured":"Shintani, H. (1995a) The relative safety of gamma-ray, autoclave, and ethylene oxide gas sterilization of thermosetting polyurethanes. <i>Biomed. Instrument. Technol<\/i>., <b>29<\/b>, 513-519."},{"key":"43","doi-asserted-by":"crossref","unstructured":"Shintani, H (1995b) Formation and elution of toxic compounds from sterilized medical products: methylenedianiline formation in polyurethane. <i>J. Biomater. Appl<\/i>., <b>10<\/b>, 23-58.","DOI":"10.1177\/088532829501000102"},{"key":"44","unstructured":"Shintani, H. (1995c) Comparison of D10-value accuracy by the limited Sperman-Karber procedure (LSKP), the Stumbo-Murphy-Cochran procedure (SMCP), and the survival-curve method (EN). <i>Biomed. Instrument. Technol<\/i>., <b>29<\/b>, 113-124."},{"key":"45","doi-asserted-by":"crossref","unstructured":"Shintani, H. (1996a) Formation and elution if toxic compounds from sterilized medical products: Toxic compound formation from irradiated products. <i>Rad. Phys. Chem<\/i>., <b>47<\/b>, 139-148.","DOI":"10.1016\/0969-806X(94)00135-7"},{"key":"46","doi-asserted-by":"crossref","unstructured":"Shintani, H. (1996b) Comparison of solid phase extraction and dialysis on pretreatment efficiency of blood urea analysis. <i>J. Chromatogr. Science<\/i>, <b>34<\/b>, 92-98.","DOI":"10.1093\/chromsci\/34.2.92"},{"key":"47","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2001a) Confirmation of the sterility of medical devices and changes in the characteristics of polymers upon sterilization. <i>Biocontyrol Science<\/i>, <b>6<\/b>, 63-68.","DOI":"10.4265\/bio.6.63"},{"key":"48","doi-asserted-by":"crossref","unstructured":"Shintani, H (2001b) Determination of the endocrine disrupter bisphenol-A in the blood of uremia patients treated by dialysis. <i>Chromatographia<\/i>, <b>53<\/b>, 331-333.","DOI":"10.1007\/BF02490435"},{"key":"49","unstructured":"Shintani, H. (2004a) Study on radiation sterilization-Resistant polysulfones fabricated free from bisphenol A. <i>Trends Biomaterial Art. Organs<\/i>, <b>18<\/b>, 36-40."},{"key":"50","doi-asserted-by":"crossref","unstructured":"Shintani, H., taniai, E., Miki, A., Kurosu, S., and Hayashi, F. (2004b) Comparison of the collecting efficiency of microbiological air samplers. <i>J. Hosp. Infect<\/i>., <b>56<\/b>, 42-48.","DOI":"10.1016\/j.jhin.2003.08.015"},{"key":"51","unstructured":"Shintani, H. (2006a) Precautions for validation of sterilization; Sterilization with ethylene oxide gas (EOG). <i>J. Antibacterial Antifungal Agents<\/i>, <b>34<\/b>, 721-729."},{"key":"52","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2006b) Importance of considering injured microorganisms in sterilization validation. <i>Biocontrol Science<\/i>, <b>11<\/b>, 91-106.","DOI":"10.4265\/bio.11.91"},{"key":"53","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2012) Formation and elution of toxic compounds from \u03b3-ray sterilized medical products: Toxic compound formation and Ames test of eluted components. <i>Pharmaceutical Analyt. Acta<\/i>. http:\/\/dx.doi.org.\/10.4172\/2153-2435.1000185","DOI":"10.4172\/2153-2435.1000185"},{"key":"54","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2013a) Rapid Assay of Airborne Microorganisms and Bioburden using Several Procedures. <i>Pharmaceutica Analytica Acta<\/i>, <b>4<\/b>:246. Doi: 10.4172\/2153-2435.1000246.","DOI":"10.4172\/2153-2435.1000246"},{"key":"55","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2013b) Importance considering increased recovery of injured microorganisms to attain reproducible sterilization validation. <i>Pharmaceutica Analytica Acta<\/i>. <b>4<\/b>: 210. Doi: 10.4172\/2153-2435.1000210.","DOI":"10.4172\/2153-2435.1000210"},{"key":"56","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2014a) Comparison of safety concern among gamma-ray, autoclave and ethylene-oxide gas sterilizations of thermosetting polyurethane. <i>Pharmaceutical Regulatory Affairs<\/i>, <b>3<\/b>: e139 doi; 10.4172\/2167-7689.1000e139.","DOI":"10.4172\/2167-7689.1000e139"},{"key":"57","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2014b) Serum or saliva extraction of toxic compound from methylmethacrylate dental materials and HPLC analysis combined with SPE. <i>Pharmaceutical Regulatory Affairs<\/i>. <b>3<\/b>: 123. Doi: 10.4172\/2167-7689. 1000123.","DOI":"10.4172\/2167-7689"},{"key":"58","doi-asserted-by":"crossref","unstructured":"Shintani, H. (2014c) Body fluid extraction of toxic dental materials made from methylmethacrylate and HPLC analysis combined with automated SPE. <i>Int. J. Clin. Pharm. Toxicol<\/i>., <b>3<\/b>, 1-8.","DOI":"10.19070\/2167-910X-140005e"},{"key":"59","doi-asserted-by":"crossref","unstructured":"Swenberg, J. A., Ham, A., Koc, H., Morinello, E., Ranasinghe, A., Tretyakova, N., Upton, R B., and Wu, K.-Y. (2000) DNA adducts: Effects of low exposure to ethylene oxide. vinyl chloride and butadiene. <i>Mutation Res<\/i>., <b>464<\/b>, 77-86.","DOI":"10.1016\/S1383-5718(99)00168-0"},{"key":"60","doi-asserted-by":"crossref","unstructured":"Valdez-Flores, C., Sielken, R. L., and Teta, M. J. (2010) Quantitative cancer risk assessment based on NIOSH and UCC epidemiological data for workers exposed to ethylene oxide. <i>Regulatory Toxicology Pharma<\/i>., <b>56<\/b>, 312-320.","DOI":"10.1016\/j.yrtph.2009.10.001"},{"key":"61","doi-asserted-by":"crossref","unstructured":"Vink, R., and Pleijsier, K. (1986) Aeration of ethylene oxidesterilized polymers. <i>Biomaterials<\/i>, <b>7<\/b>, 225-230.","DOI":"10.1016\/0142-9612(86)90108-0"}],"container-title":["Biocontrol Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/bio\/22\/1\/22_1\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T21:14:36Z","timestamp":1692738876000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/bio\/22\/1\/22_1\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017]]},"references-count":61,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.4265\/bio.22.1","relation":{},"ISSN":["1342-4815","1884-0205"],"issn-type":[{"value":"1342-4815","type":"print"},{"value":"1884-0205","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017]]}}}