{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T06:22:45Z","timestamp":1767766965670,"version":"3.48.0"},"reference-count":48,"publisher":"Galenos Yayinevi","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["dir"],"DOI":"10.4274\/dir.2025.253496","type":"journal-article","created":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T10:27:49Z","timestamp":1757586469000},"source":"Crossref","is-referenced-by-count":0,"title":["Factors influencing diagnostic yield and complication risk in computed tomography fluoroscopy-guided lung biopsies: a 10-year single-center study"],"prefix":"10.4274","author":[{"given":"Nabeel","family":"Mansour","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hannah","family":"Gildein","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Frederik F.","family":"Strobl","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osman","family":"\u00d6cal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Geith","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Puhr-Westerheide","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Stechele","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sinan","family":"Deniz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muzaffer R.","family":"\u00dcm\u00fctl\u00fc","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicola","family":"Fink","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk","family":"Mehrens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Moritz","family":"Wildgruber","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Max","family":"Seidensticker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximilian F.","family":"Reiser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jens","family":"Ricke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp M.","family":"Paprottka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias P.","family":"Fabritius","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2811","published-online":{"date-parts":[[2025,9,11]]},"reference":[{"issue":"1","key":"ref0","doi-asserted-by":"publisher","first-page":"17","DOI":"10.3322\/caac.21763","article-title":"Cancer statistics, 2023","volume":"73","author":"Siegel","year":"2023","unstructured":"1. Siegel RL, Miller KD, Wagle NS, Jemal A. Cancer statistics, 2023. CA Cancer J Clin. 2023;73(1):17-48.","journal-title":"CA Cancer J Clin"},{"issue":"10374","key":"ref1","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/S0140-6736(22)01694-4","article-title":"Lung cancer screening","volume":"401","author":"Adams","year":"2023","unstructured":"2. Adams SJ, Stone E, Baldwin DR, Vliegenthart R, Lee P, Fintelmann FJ. Lung cancer screening. Lancet. 2023;401(10374):390-408.","journal-title":"Lancet"},{"issue":"5","key":"ref2","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1056\/NEJMoa1102873","article-title":"Reduced lung-cancer mortality with low-dose computed tomographic screening","volume":"365","author":"Lung Screening Trial Research Team","year":"2011","unstructured":"3. National Lung Screening Trial Research Team; Aberle DR, Adams AM, et al. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med. 2011;365(5):395-409.","journal-title":"N Engl J Med"},{"issue":"22","key":"ref3","doi-asserted-by":"publisher","first-page":"3976","DOI":"10.1002\/cncr.28326","article-title":"The National Lung Screening Trial: results strati-fied by demographics, smoking history, and lung cancer histology","volume":"119","author":"Pinsky","year":"2013","unstructured":"4. Pinsky PF, Church TR, Izmirlian G, Kramer BS. The National Lung Screening Trial: results strati-fied by demographics, smoking history, and lung cancer histology. Cancer. 2013;119(22):3976-3983.","journal-title":"Cancer"},{"issue":"12","key":"ref4","doi-asserted-by":"publisher","first-page":"1332","DOI":"10.1016\/S1470-2045(14)70389-4","article-title":"Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecified analysis of data from the NELSON trial of low-dose CT screening","volume":"15","author":"Horeweg","year":"2014","unstructured":"5. Horeweg N, van Rosmalen J, Heuvelmans MA, et al. Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecified analysis of data from the NELSON trial of low-dose CT screening. Lancet Oncol. 2014;15(12):1332-1341.","journal-title":"Lancet Oncol"},{"issue":"5","key":"ref5","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1164\/rccm.201505-1040OC","article-title":"Results of the randomized Danish lung cancer screening trial with focus on high-risk profiling","volume":"193","author":"Wille","year":"2016","unstructured":"6. Wille MM, Dirksen A, Ashraf H, et al. Results of the randomized Danish lung cancer screening trial with focus on high-risk profiling. Am J Respir Crit Care Med. 2016;193(5):542-551.","journal-title":"Am J Respir Crit Care Med"},{"issue":"9","key":"ref6","doi-asserted-by":"publisher","first-page":"825","DOI":"10.1136\/thoraxjnl-2016-209825","article-title":"Mortality, survival and incidence rates in the ITALUNG randomi-sed lung cancer screening trial","volume":"72","author":"Paci","year":"2017","unstructured":"7. Paci E, Puliti D, Pegna AL, et al. Mortality, survival and incidence rates in the ITALUNG randomi-sed lung cancer screening trial. Thorax. 2017;72(9):825-831.","journal-title":"Thorax"},{"key":"ref7","doi-asserted-by":"publisher","unstructured":"8. Pastorino U, Silva M, Sestini S, et al. Prolonged lung cancer screening reduced 10-year morta-lity in the MILD trial: new confirmation of lung cancer screening efficacy. Ann Oncol. 2019;30(7):1162-1169. Erratum in: Ann Oncol. 2019;30(10):1672.","DOI":"10.1093\/annonc\/mdz117"},{"issue":"6","key":"ref8","doi-asserted-by":"publisher","first-page":"1503","DOI":"10.1002\/ijc.32486","article-title":"Lung cancer mortality reduction by LDCT screening-results from the randomized German LUSI trial","volume":"146","author":"Becker","year":"2020","unstructured":"9. Becker N, Motsch E, Trotter A, et al. Lung cancer mortality reduction by LDCT screening-results from the randomized German LUSI trial. Int J Cancer. 2020;146(6):1503-1513.","journal-title":"Int J Cancer"},{"issue":"6","key":"ref9","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1056\/NEJMoa1911793","article-title":"Reduced lung-cancer mortality with volume CT screening in a randomized trial","volume":"382","author":"de Koning","year":"2020","unstructured":"10. de Koning HJ, van der Aalst CM, de Jong PA, et al. Reduced lung-cancer mortality with volume CT screening in a randomized trial. N Engl J Med. 2020;382(6):503-513.","journal-title":"N Engl J Med"},{"issue":"9","key":"ref10","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1513\/AnnalsATS.201612-1023OC","article-title":"Frequency of incidental findings and sub-sequent evaluation in low-dose computed tomographic scans for lung cancer screening","volume":"14","author":"Morgan","year":"2017","unstructured":"11. Morgan L, Choi H, Reid M, Khawaja A, Mazzone PJ. Frequency of incidental findings and sub-sequent evaluation in low-dose computed tomographic scans for lung cancer screening. Ann Am Thorac Soc. 2017;14(9):1450-1456.","journal-title":"Ann Am Thorac Soc"},{"issue":"2","key":"ref11","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1097\/RCT.0b013e3181585ff2","article-title":"Prevalence of incidental findings in compu-ted tomographic screening of the chest: a systematic review","volume":"32","author":"Jacobs","year":"2008","unstructured":"12. Jacobs PC, Mali WP, Grobbee DE, van der Graaf Y. Prevalence of incidental findings in compu-ted tomographic screening of the chest: a systematic review. J Comput Assist Tomogr. 2008;32(2):214-221.","journal-title":"J Comput Assist Tomogr"},{"issue":"3","key":"ref12","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1053\/j.sult.2018.02.005","article-title":"Incidental findings on lung cancer screening: significance and management","volume":"39","author":"Tsai","year":"2018","unstructured":"13. Tsai EB, Chiles C, Carter BW, et al. Incidental findings on lung cancer screening: significance and management. Semin Ultrasound CT MR. 2018;39(3):273-281.","journal-title":"Semin Ultrasound CT MR"},{"issue":"22","key":"ref13","doi-asserted-by":"publisher","first-page":"2418","DOI":"10.1001\/jama.2012.5521","article-title":"Benefits and harms of CT screening for lung cancer: a sys-tematic review","volume":"307","author":"Bach","year":"2012","unstructured":"14. Bach PB, Mirkin JN, Oliver TK, et al. Benefits and harms of CT screening for lung cancer: a sys-tematic review. JAMA. 2012;307(22):2418-2429.","journal-title":"JAMA"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1186\/s12916-021-01928-3","article-title":"Automated detection of lung nodules and coronary ar-tery calcium using artificial intelligence on low-dose CT scans for lung cancer screening: accu-racy and prognostic value","volume":"19","author":"Chamberlin","year":"2021","unstructured":"15. Chamberlin J, Kocher MR, Waltz J, et al. Automated detection of lung nodules and coronary ar-tery calcium using artificial intelligence on low-dose CT scans for lung cancer screening: accu-racy and prognostic value. BMC Med. 2021;19:55.","journal-title":"BMC Med"},{"issue":"17","key":"ref15","doi-asserted-by":"publisher","first-page":"4344","DOI":"10.3390\/cancers15174344","article-title":"Artificial intelligence in lung cancer screening: the future is now","volume":"15","author":"Cellina","year":"2023","unstructured":"16. Cellina M, Cacioppa LM, C\u00e8 M, et al. Artificial intelligence in lung cancer screening: the future is now. Cancers (Basel). 2023;15(17):4344.","journal-title":"Cancers (Basel)"},{"issue":"5","key":"ref16","doi-asserted-by":"publisher","first-page":"2378","DOI":"10.21037\/tlcr-2020-lcs-06","article-title":"Artificial intelligence for detection and characterization of pulmonary nodules in lung cancer CT screening: ready for practice","volume":"10","author":"Schreuder","year":"2021","unstructured":"17. Schreuder A, Scholten ET, van Ginneken B, Jacobs C. Artificial intelligence for detection and characterization of pulmonary nodules in lung cancer CT screening: ready for practice? Transl Lung Cancer Res. 2021;10(5):2378-2388.","journal-title":"Transl Lung Cancer Res"},{"key":"ref17","unstructured":"18. Folch E, Costa DB, Wright J, VanderLaan PA. Lung cancer diagnosis and staging in the mini-mally invasive age with increasing demands for tissue analysis. Transl Lung Cancer Res. 2015;4(4):392-403."},{"issue":"12","key":"ref18","doi-asserted-by":"publisher","first-page":"1529","DOI":"10.1158\/2159-8290.CD-18-1022","article-title":"Landscape of acquired resistance to osimertinib in EGFR-mutant NSCLC and clinical validation of combined EGFR and RET inhibition with osi-mertinib and BLU-667 for acquired RET fusion","volume":"8","author":"Piotrowska","year":"2018","unstructured":"19. Piotrowska Z, Isozaki H, Lennerz JK, et al. Landscape of acquired resistance to osimertinib in EGFR-mutant NSCLC and clinical validation of combined EGFR and RET inhibition with osi-mertinib and BLU-667 for acquired RET fusion. Cancer discovery. 2018;8(12):1529-1539.","journal-title":"Cancer discovery"},{"issue":"10","key":"ref19","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1158\/2159-8290.CD-16-0596","article-title":"Molecular mechanisms of resistance to first-and second-generation ALK inhibitors in ALK-rearranged lung cancer","volume":"6","author":"Gainor","year":"2016","unstructured":"20. Gainor JF, Dardaei L, Yoda S, et al. Molecular mechanisms of resistance to first-and second-generation ALK inhibitors in ALK-rearranged lung cancer. Cancer Discov. 2016;6(10):1118-1133.","journal-title":"Cancer Discov"},{"issue":"1","key":"ref20","doi-asserted-by":"publisher","first-page":"2898962","DOI":"10.1155\/2018\/2898962","article-title":"Prospective evaluation of unprocessed core needle biopsy DNA and RNA yield from lung, liver, and kidney tumors: implications for cancer genomics","volume":"2018","author":"Silk","year":"2018","unstructured":"21. Silk MT, Mikkilineni N, Silk TC, et al. Prospective evaluation of unprocessed core needle biopsy DNA and RNA yield from lung, liver, and kidney tumors: implications for cancer genomics. Anal Cell Pathol (Amst). 2018;2018(1):2898962.","journal-title":"Anal Cell Pathol (Amst)"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.lungcan.2019.06.005","article-title":"Heterogeneity of PD-L1 expres-sion in non-small cell lung cancer: Implications for specimen sampling in predicting treatment response","volume":"134","author":"Haragan","year":"2019","unstructured":"22. Haragan A, Field JK, Davies MPA, Escriu C, Gruver A, Gosney JR. Heterogeneity of PD-L1 expres-sion in non-small cell lung cancer: Implications for specimen sampling in predicting treatment response. Lung Cancer. 2019;134:79-84.","journal-title":"Lung Cancer"},{"issue":"23","key":"ref22","doi-asserted-by":"publisher","first-page":"5879","DOI":"10.3390\/cancers13235879","article-title":"The impact of core tissues on successful next-generation sequencing analysis of specimens obtained through endobronchial ultrasound-guided transbronchial needle aspiration","volume":"13","author":"Uchimura","year":"2021","unstructured":"23. Uchimura K, Yanase K, Imabayashi T, et al. The impact of core tissues on successful next-generation sequencing analysis of specimens obtained through endobronchial ultrasound-guided transbronchial needle aspiration. Cancers (Basel). 2021;13(23):5879.","journal-title":"Cancers (Basel)"},{"issue":"6","key":"ref23","doi-asserted-by":"publisher","first-page":"1612","DOI":"10.1378\/chest.09-0370","article-title":"CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnos-tic failure","volume":"136","author":"Hiraki","year":"2009","unstructured":"24. Hiraki T, Mimura H, Gobara H, et al. CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnos-tic failure. Chest. 2009;136(6):1612-1617.","journal-title":"Chest"},{"issue":"3","key":"ref24","doi-asserted-by":"publisher","first-page":"83","DOI":"10.22575\/interventionalradiology.2021-0012","article-title":"Computed tomography-guided lung biopsy: a review of techniques for reducing the incidence of complications","volume":"6","author":"Nakamura","year":"2021","unstructured":"25. Nakamura K, Matsumoto K, Inoue C, Matsusue E, Fujii S. Computed tomography-guided lung biopsy: a review of techniques for reducing the incidence of complications. Interv Radiol (Hi-gashimatsuyama). 2021;6(3):83-92.","journal-title":"Interv Radiol (Hi-gashimatsuyama)"},{"issue":"7","key":"ref25","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1016\/S1051-0443(07)61805-3","article-title":"Value of CT fluoroscopy for percutaneous biopsy procedures","volume":"11","author":"Gianfelice","year":"2000","unstructured":"26. Gianfelice D, Lepanto L, Perreault P, Chartrand-Lefebvre C, Milette PC. Value of CT fluoroscopy for percutaneous biopsy procedures. J Vasc Interv Radiol. 2000;11(7):879-884.","journal-title":"J Vasc Interv Radiol"},{"issue":"1","key":"ref26","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/S0720-048X(01)00391-6","article-title":"Guidance of percutaneous pul-monary biopsies with real-time CT fluoroscopy","volume":"42","author":"Froelich","year":"2002","unstructured":"27. Froelich JJ, Ishaque N, Regn J, Saar B, Walthers EM, Klose KJ. Guidance of percutaneous pul-monary biopsies with real-time CT fluoroscopy. Eur J Radiol. 2002;42(1):74-79.","journal-title":"Eur J Radiol"},{"issue":"2","key":"ref27","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1007\/s00330-010-1936-y","article-title":"CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic perfor-mance","volume":"21","author":"Kim","year":"2011","unstructured":"28. Kim GR, Hur J, Lee SM, et al. CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic perfor-mance. Eur Radiol. 2011;21(2):232-239.","journal-title":"Eur Radiol"},{"issue":"11","key":"ref28","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1136\/thorax.58.11.920","article-title":"Guidelines for radiologically guided lung biopsy","volume":"58","author":"Manhire","year":"2003","unstructured":"29. Manhire A, Charig M, Clelland C, et al. Guidelines for radiologically guided lung biopsy. Thorax. 2003;58(11):920-936.","journal-title":"Thorax"},{"issue":"8","key":"ref29","doi-asserted-by":"publisher","first-page":"1168","DOI":"10.1016\/j.jvir.2019.04.017","article-title":"Society of Interventional Radiology Consensus Guidelines for the Periprocedural Management of Thrombotic and Bleeding Risk in Patients Undergoing Percutaneous Image-Guided Interven-tions-Part II: Recommendations: Endorsed by the Canadian Association for Interventional Ra-diology and the Cardiovascular and Interventional Radiological Society of Europe","volume":"30","author":"Patel","year":"2019","unstructured":"30. Patel IJ, Rahim S, Davidson JC, Hanks SE, Tam AL, Walker TG, Wilkins LR, Sarode R, Weinberg I. Society of Interventional Radiology Consensus Guidelines for the Periprocedural Management of Thrombotic and Bleeding Risk in Patients Undergoing Percutaneous Image-Guided Interven-tions-Part II: Recommendations: Endorsed by the Canadian Association for Interventional Ra-diology and the Cardiovascular and Interventional Radiological Society of Europe. J Vasc Interv Radiol. 2019;30(8):1168-1184.","journal-title":"J Vasc Interv Radiol"},{"issue":"7","key":"ref30","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/j.jvir.2010.01.011","article-title":"Quality improvement guidelines for percutaneous need-le biopsy","volume":"21","author":"Gupta","year":"2010","unstructured":"31. Gupta S, Wallace MJ, Cardella JF, Kundu S, Miller DL, Rose SC; Society of Interventional Radio-logy Standards of Practice Committee. Quality improvement guidelines for percutaneous need-le biopsy. J Vasc Interv Radiol. 2010;21(7):969-975.","journal-title":"J Vasc Interv Radiol"},{"key":"ref31","doi-asserted-by":"publisher","unstructured":"32. Sacks D, McClenny TE, Cardella JF, Lewis CA. Society of Interventional Radiology clinical prac-tice guidelines. J Vasc Interv Radiol. 2003;14(9 Pt 2):199-202.","DOI":"10.1097\/01.RVI.0000094584.83406.3e"},{"issue":"1","key":"ref32","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1148\/radiol.10100047","article-title":"Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product","volume":"257","author":"Deak","year":"2010","unstructured":"33. Deak PD, Smal Y, Kalender WA. Multisection CT protocols: sex-and age-specific conversion factors used to determine effective dose from dose-length product. Radiology. 2010;257(1):158-166.","journal-title":"Radiology"},{"issue":"1","key":"ref33","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","article-title":"Eur Radiol","volume":"27","author":"Heerink","year":"2017","unstructured":"34. Heerink WJ, de Bock GH, de Jonge GJ, Groen HJ, Vliegenthart R, Oudkerk M. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis. Eur Radiol. Eur Radiol. 2017;27(1):138-148.","journal-title":"Eur Radiol"},{"key":"ref34","doi-asserted-by":"publisher","unstructured":"35. Ren Q, Zhou Y, Yan M, Zheng C, Zhou G, Xia X. Imaging-guided percutaneous transthoracic ne-edle biopsy of nodules in the lung base: fluoroscopy CT versus cone-beam CT. Clin Radiol. 2022;77(5):e394-e399.","DOI":"10.1016\/j.crad.2022.02.005"},{"issue":"6","key":"ref35","doi-asserted-by":"publisher","first-page":"4243","DOI":"10.1007\/s00330-020-07449-6","article-title":"Predictors of pneumothorax and chest drainage after percutaneous CT-guided lung biopsy: a prospective study","volume":"31","author":"Ruud","year":"2021","unstructured":"36. Ruud EA, Stavem K, Geitung JT, Borthne A, S\u00f8yseth V, Ashraf H. Predictors of pneumothorax and chest drainage after percutaneous CT-guided lung biopsy: a prospective study. Eur Radiol. 2021;31(6):4243-4252.","journal-title":"Eur Radiol"},{"issue":"3","key":"ref36","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1378\/chest.126.3.666","article-title":"Complications of CT scan-guided lung biopsy: lesion size and depth matter","volume":"126","author":"Gohari","year":"2004","unstructured":"37. Gohari A, Haramati LB. Complications of CT scan-guided lung biopsy: lesion size and depth matter. Chest. 2004;126(3):666-668.","journal-title":"Chest"},{"issue":"5","key":"ref37","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1097\/01.RVI.0000071087.76348.C7","article-title":"Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures","volume":"14","author":"Yeow","year":"2003","unstructured":"38. Yeow KM, Tsay PK, Cheung YC, Lui KW, Pan KT, Chou AS. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol. 2003;14(5):581-588.","journal-title":"J Vasc Interv Radiol"},{"key":"ref38","doi-asserted-by":"publisher","unstructured":"39. Ozturk K, Soylu E, Gokalp G, Topal U. Risk factors of pneumothorax and chest tube placement after computed tomography-guided core needle biopsy of lung lesions: a single-centre expe-rience with 822 biopsies. Pol J Radiol. 2018;83:e407-e414.","DOI":"10.5114\/pjr.2018.79205"},{"issue":"1","key":"ref39","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/s40644-019-0240-6","article-title":"Accuracy and complications of CT-guided pulmonary core biopsy in small nodules: a single-center experience","volume":"19","author":"Huang","year":"2019","unstructured":"40. Huang MD, Weng HH, Hsu SL, et al. Accuracy and complications of CT-guided pulmonary core biopsy in small nodules: a single-center experience. Cancer Imaging. 2019;19(1):51.","journal-title":"Cancer Imaging"},{"issue":"2","key":"ref40","doi-asserted-by":"publisher","first-page":"333","DOI":"10.21037\/jtd.2017.02.16","article-title":"CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing","volume":"9","author":"Tian","year":"2017","unstructured":"41. Tian P, Wang Y, Li L, Zhou Y, Luo W, Li W. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing. J Thorac Dis. 2017;9(2):333-343.","journal-title":"J Thorac Dis"},{"key":"ref41","doi-asserted-by":"publisher","unstructured":"42. Kim CR, Sari MA, Grimaldi E, VanderLaan PA, Brook A, Brook OR. CT-guided coaxial lung bi-opsy: number of cores and association with complications. Radiology. 2024;313(2):e232168.","DOI":"10.1148\/radiol.232168"},{"issue":"3","key":"ref42","doi-asserted-by":"publisher","first-page":"753","DOI":"10.21037\/jtd.2019.02.48","article-title":"CT-guided coaxial biopsy of malignant lung lesions: are cores from 20-gauge needle adequate for histologic diagnosis and molecular analysis","volume":"11","author":"Beck","year":"2019","unstructured":"43. Beck KS, Kim TJ, Lee KY, Kim YK, Kang JH, Han DH. CT-guided coaxial biopsy of malignant lung lesions: are cores from 20-gauge needle adequate for histologic diagnosis and molecular analysis? J Thorac Dis. 2019;11(3):753-765.","journal-title":"J Thorac Dis"},{"issue":"11","key":"ref43","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.3390\/diagnostics14111089","article-title":"Computed-tomography-guided lung biopsy: a practice-oriented document on techniques and principles and a review of the literature","volume":"14","author":"Saggiante","year":"2024","unstructured":"44. Saggiante L, Biondetti P, Lanza C, et al. Computed-tomography-guided lung biopsy: a practice-oriented document on techniques and principles and a review of the literature. Diagnostics (Basel). 2024;14(11):1089.","journal-title":"Diagnostics (Basel)"},{"issue":"2","key":"ref44","doi-asserted-by":"publisher","first-page":"359","DOI":"10.3390\/diagnostics12020359","article-title":"CT-guided transthoracic biopsy of pulmonary lesions: diagnostic versus nondiagnostic results","volume":"12","author":"Borelli","year":"2022","unstructured":"45. Borelli C, Vergara D, Simeone A, et al. CT-guided transthoracic biopsy of pulmonary lesions: diagnostic versus nondiagnostic results. Diagnostics (Basel). 2022;12(2):359.","journal-title":"Diagnostics (Basel)"},{"key":"ref45","doi-asserted-by":"publisher","unstructured":"46. Schmanke KE, Zackula RE, Unruh ZA, Burdiek WA, Trent JJ, Ali KM. Resident experience associ-ated with lung biopsy outcomes: a cross-sectional study of diagnostic radiology residents. Does the Level of Training Matter? Kans J Med. 2020;13:235-241.","DOI":"10.17161\/kjm.v13i.14632"},{"issue":"2","key":"ref46","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1007\/s00330-010-1936-y","article-title":"CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic perfor-mance","volume":"21","author":"Kim","year":"2011","unstructured":"47. Kim GR, Hur J, Lee SM, et al. CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic perfor-mance. Eur Radiol. 2011;21(2):232-239.","journal-title":"Eur Radiol"},{"key":"ref47","doi-asserted-by":"publisher","unstructured":"48. McCollough CH, Rajiah PS. Milestones in CT: Past, present, and future. Radiology. 2023;309(1):e230803.","DOI":"10.1148\/radiol.230803"}],"container-title":["Diagnostic and Interventional Radiology"],"original-title":[],"deposited":{"date-parts":[[2026,1,7]],"date-time":"2026-01-07T06:20:40Z","timestamp":1767766840000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.dirjournal.org\/articles\/factors-influencing-diagnostic-yield-and-complication-risk-in-computed-tomography-fluoroscopy-guided-lung-biopsies-a-10-year-single-center-study\/doi\/dir.2025.253496"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,11]]},"references-count":48,"URL":"https:\/\/doi.org\/10.4274\/dir.2025.253496","relation":{},"ISSN":["1305-3825","1305-3612"],"issn-type":[{"type":"print","value":"1305-3825"},{"type":"electronic","value":"1305-3612"}],"subject":[],"published":{"date-parts":[[2025,9,11]]}}}