{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T02:51:28Z","timestamp":1774493488054,"version":"3.50.1"},"reference-count":45,"publisher":"Baishideng Publishing Group Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["World J Radiol"],"abstract":"<jats:p>BACKGROUND<\/jats:p>\n                  <jats:p>Metal artifacts significantly limit the diagnostic quality of computed tomography (CT) algorithm in patients with lower limb metallic prostheses. Single-energy metal artifact reduction (SEMAR) algorithms have been developed to address this limitation.<\/jats:p>\n                  <jats:p>AIM<\/jats:p>\n                  <jats:p>To evaluate the effects of SEMAR algorithm on image quality characteristics of lower limb CT algorithm (CTA) (artifact reduction, signal-to-noise ratio (SNR) and inter-observer agreement) in patients with metallic prostheses.<\/jats:p>\n                  <jats:p>METHODS<\/jats:p>\n                  <jats:p>Twenty-two patients (14 males, 8 females; median age 54 years) with unilateral or bilateral metal lower limb prostheses or screws underwent lower limb CTA on a 128-slice multi-detector CT scanner. Images were reconstructed with and without SEMAR algorithm. Three radiologists independently assessed subjective image quality using standardized scoring systems. Quantitative analysis included measurement of SNR and contrast-to-noise ratio in arterial and soft tissue regions of interest.<\/jats:p>\n                  <jats:p>RESULTS<\/jats:p>\n                  <jats:p>Application of SEMAR significantly improved SNR in two of three observers (P  = 0.009 and P  = 0.004), with values approaching those in the contralateral reference limb. Overall artifact reduction was statistically significant (median difference 1.5 Hounsfield unit, P  &lt; 0.001), as was improvement in overall image quality (median difference 1 Hounsfield unit, P  &lt; 0.001). Good inter-observer agreement (intraclass correlation coefficient &gt; 0.75) was demonstrated for SNR and contrast-to-noise ratio assessment with metal artifact reduction (MAR) and reference images, while poor agreement (intraclass correlation coefficient &lt; 0.5) was noted for non-MAR images. Kendall\u2019s W  demonstrated significant concordance among observers (W  = 0.899, P  &lt; 0.001 for study quality with MAR).<\/jats:p>\n                  <jats:p>CONCLUSION<\/jats:p>\n                  <jats:p>SEMAR algorithm significantly reduces metal artifacts from lower limb fixation prostheses without compromising vessel contrast, improving visualization of periprosthetic vascular structures and enhancing diagnostic capability of CTA examinations.<\/jats:p>","DOI":"10.4329\/wjr.v18.i3.118119","type":"journal-article","created":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T01:54:20Z","timestamp":1774490060000},"source":"Crossref","is-referenced-by-count":0,"title":["Role of metal artifact reduction software in computed tomography angiography of lower limb metallic prosthesis: A retrospective study"],"prefix":"10.4329","volume":"18","author":[{"given":"Ahmad M","family":"Mounir","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali H","family":"Elmokadem","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gehad A H","family":"Saleh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ahmed","family":"El-Morsy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ghada H","family":"Abd El-Raouf","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2060","published-online":{"date-parts":[[2026,3,28]]},"reference":[{"key":"B1","doi-asserted-by":"publisher","DOI":"10.1212\/01.WNL.0000148958.34025.09"},{"key":"B2","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A1803"},{"key":"B3","doi-asserted-by":"publisher","DOI":"10.1016\/j.crad.2017.07.011"},{"key":"B4","doi-asserted-by":"publisher","DOI":"10.1148\/rg.273065087"},{"key":"B5","doi-asserted-by":"publisher","DOI":"10.1159\/000346087"},{"key":"B6","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.10.5329"},{"key":"B7","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A0662"},{"key":"B8","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2831"},{"key":"B9","doi-asserted-by":"publisher","DOI":"10.1148\/rg.2018170102"},{"key":"B10","unstructured":"Masaryk AM, Frayne R, Unal O, Rappe AH, Strother CM. Utility of CT angiography and MR angiography for the follow-up of experimental aneurysms treated with stents or Guglielmi detachable coils. AJNR Am J Neuroradiol 2000; 1523-1531"},{"key":"B11","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4649"},{"key":"B12","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2014-011459"},{"key":"B13","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4079"},{"key":"B14","doi-asserted-by":"publisher","DOI":"10.1097\/RLI.0000000000000052"},{"key":"B15","doi-asserted-by":"publisher","DOI":"10.3171\/2008.10.SPI08627"},{"key":"B16","doi-asserted-by":"publisher","DOI":"10.1117\/12.2043661"},{"key":"B17","doi-asserted-by":"publisher","DOI":"10.1118\/1.3567509"},{"key":"B18","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.12.9121"},{"key":"B19","doi-asserted-by":"publisher","DOI":"10.1259\/bjr.20150993"},{"key":"B20","doi-asserted-by":"publisher","DOI":"10.1177\/2058460117693463"},{"key":"B21","doi-asserted-by":"publisher","DOI":"10.1118\/1.4905106"},{"key":"B22","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-018-2081-6"},{"key":"B23","doi-asserted-by":"publisher","DOI":"10.1109\/NSSMIC.2012.6551781"},{"key":"B24","doi-asserted-by":"publisher","DOI":"10.1016\/j.diii.2016.07.002"},{"key":"B25","doi-asserted-by":"publisher","DOI":"10.1016\/j.diii.2015.11.018"},{"key":"B26","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2014.10.003"},{"key":"B27","unstructured":"European Study Group.   European Guidelines on Quality Criteria for Computed Tomography. Luxembourg: Office for Official Publications of the European Communities, 2000"},{"key":"B28","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2017.06.003"},{"key":"B29","doi-asserted-by":"publisher","DOI":"10.1007\/s00270-017-1812-0"},{"key":"B30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcm.2016.02.012"},{"key":"B31","doi-asserted-by":"publisher","DOI":"10.1136\/neurintsurg-2015-011787"},{"key":"B32","doi-asserted-by":"publisher","DOI":"10.1177\/0284185113510492"},{"key":"B33","doi-asserted-by":"publisher","DOI":"10.1148\/rg.263055182"},{"key":"B34","unstructured":"van der Schaaf I, van Leeuwen M, Vlassenbroek A, Velthuis B. Minimizing clip artifacts in multi CT angiography of clipped patients. AJNR Am J Neuroradiol 2006; 60-66"},{"key":"B35","doi-asserted-by":"publisher","DOI":"10.1007\/s00062-017-0644-2"},{"key":"B36","doi-asserted-by":"publisher","DOI":"10.1097\/RCT.0b013e3182058d5c"},{"key":"B37","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-009-1300-2"},{"key":"B38","doi-asserted-by":"publisher","DOI":"10.1118\/1.4906245"},{"key":"B39","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-008-0630-5"},{"key":"B40","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A4386"},{"key":"B41","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-013-2885-z"},{"key":"B42","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-014-1923-5"},{"key":"B43","doi-asserted-by":"publisher","DOI":"10.1007\/s11604-015-0478-2"},{"key":"B44","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-015-3950-6"},{"key":"B45","doi-asserted-by":"publisher","DOI":"10.1007\/s00330-016-4660-4"}],"container-title":["World Journal of Radiology"],"original-title":[],"link":[{"URL":"https:\/\/www.wjgnet.com\/1949-8470\/full\/v18\/i3\/118119.htm","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.wjgnet.com\/1949-8470\/full\/v18\/i3\/118119.htm","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T01:54:29Z","timestamp":1774490069000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.wjgnet.com\/1949-8470\/full\/v18\/i3\/118119.htm"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,28]]},"references-count":45,"journal-issue":{"issue":"3"},"alternative-id":["118119"],"URL":"https:\/\/doi.org\/10.4329\/wjr.v18.i3.118119","relation":{},"ISSN":["1949-8470"],"issn-type":[{"value":"1949-8470","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3,28]]}}}