{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T22:52:48Z","timestamp":1769813568764,"version":"3.49.0"},"reference-count":42,"publisher":"Universitat Politecnica de Valencia","issue":"1","license":[{"start":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T00:00:00Z","timestamp":1769472000000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J APPL RES TECH ENG"],"abstract":"<jats:p>This article establishes a non-parametric validation framework for photoplethysmography (PPG) signals intended for heart rate monitoring, formulated as a methodological proof-of-concept study. The study applies the two-sample Kolmogorov\u2013Smirnov test as a robust and versatile method for comparing the distributions of PPG signals. By integrating the two-sample Kolmogorov\u2013Smirnov test into the validation process of cardiac pulse measurement devices, the work demonstrates its effectiveness in enhancing the accuracy and reliability of biomedical signal analysis. Results show that, when comparing signals against calibrated reference devices and visualizing cumulative distribution functions, the two-sample Kolmogorov\u2013Smirnov test is capable of detecting subtle differences in signal behavior. This innovative use of the two-sample Kolmogorov\u2013Smirnov test provides valuable insights for the design and validation of biomedical signal processing systems and contributes to the advancement of non-invasive health monitoring technologies. The proposed framework is evaluated under controlled experimental conditions using data acquired from a single subject. Consequently, the results should be interpreted as a methodological validation of the proposed statistical approach rather than as a definitive clinical validation, and are intended to demonstrate feasibility and analytical relevance rather than population-level generalizability.<\/jats:p>","DOI":"10.4995\/jarte.2026.24883","type":"journal-article","created":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T11:47:48Z","timestamp":1769773668000},"page":"58-70","source":"Crossref","is-referenced-by-count":0,"title":["A non-parametric validation framework for photoplethysmography-based heart rate monitoring: a proof-of-concept study using the two-sample Kolmogorov\u2013Smirnov test"],"prefix":"10.4995","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1684-6647","authenticated-orcid":false,"given":"Javier","family":"Cruz-Salgado","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3180-8825","authenticated-orcid":false,"given":"Roxana Zaricell","family":"Bautista-L\u00f3pez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0772-5947","authenticated-orcid":false,"given":"Javier","family":"Ya\u00f1ez-Mendiola","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0515-7667","authenticated-orcid":false,"given":"Edgar Augusto","family":"Ruelas-Santoyo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9433-7864","authenticated-orcid":false,"given":"Israel","family":"Miguel-Andr\u00e9s","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5293-4855","authenticated-orcid":false,"given":"Jos\u00e9 Alfredo","family":"Jim\u00e9nez-Garc\u00eda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2900","published-online":{"date-parts":[[2026,1,27]]},"reference":[{"key":"641414","doi-asserted-by":"crossref","unstructured":"Allen, J. (2007). Photoplethysmography and its application in clinical physiological measurement. Physiological Measurement, 28(3), R1\u2013R39. https:\/\/doi.org\/10.1088\/0967-3334\/28\/3\/R01","DOI":"10.1088\/0967-3334\/28\/3\/R01"},{"key":"641415","doi-asserted-by":"crossref","unstructured":"Anderson, R. R., & Parrish, J. A. (1981). The optics of human skin. Journal of Investigative Dermatology, 77(1), 13\u201319. https:\/\/doi.org\/10.1111\/1523-1747.ep12479191","DOI":"10.1111\/1523-1747.ep12479191"},{"key":"641416","unstructured":"Aslam, M. (2019). A new Kolmogorov\u2013Smirnov test under neutrosophic statistics. ACS Omega, 4(8), 14538\u201314543. https:\/\/doi.org\/10.1021\/acsomega.9b01319"},{"key":"641417","doi-asserted-by":"crossref","unstructured":"Ballarin, M., Refsgaard, J. C., & Madsen, H. (2022). Predictive and descriptive validation of hydrological models for extreme events: A critical review. Hydrological Sciences Journal, 67(9), 1272\u20131289. https:\/\/doi.org\/10.1080\/02626667.2022.2089450","DOI":"10.1080\/02626667.2022.2063725"},{"key":"641418","doi-asserted-by":"crossref","unstructured":"Bautista L\u00f3pez, R. Z., Y\u00e1\u00f1ez Mendiola, J., & L\u00f3pez Vela, J. M. (2023). Investigaciones y desarrollos tecnol\u00f3gicos en M\u00e9xico, (1-VII).","DOI":"10.1155\/2023\/6672198"},{"key":"641419","doi-asserted-by":"crossref","unstructured":"Bautista L\u00f3pez, R. Z., Y\u00e1\u00f1ez Mendiola, J., & Sicard Gonz\u00e1lez, M. T. (2023). Branchial motion assessment in abalone using photoplethysmography. Aquaculture Research, 1, 6672198. https:\/\/doi.org\/10.1155\/2023\/6672198","DOI":"10.1155\/2023\/6672198"},{"key":"641420","doi-asserted-by":"crossref","unstructured":"Berner, J. (2005). Linking nonlinearity and non-Gaussianity of planetary wave behavior by the Fokker\u2013Planck equation. Journal of the Atmospheric Sciences, 62, 2098\u20132117. https:\/\/doi.org\/10.1175\/JAS3468.1","DOI":"10.1175\/JAS3468.1"},{"key":"641421","doi-asserted-by":"crossref","unstructured":"Branstator, G., & Berner, J. (2005). Linear and nonlinear signatures in the planetary wave dynamics of an AGCM: Phase space tendencies. Journal of the Atmospheric Sciences, 62, 1792\u20131811. https:\/\/doi.org\/10.1175\/JAS3429.1","DOI":"10.1175\/JAS3429.1"},{"key":"641422","doi-asserted-by":"crossref","unstructured":"Burgers, G., & Stephenson, D. B. (1999). The \u201cnormality\u201d of El Ni\u00f1o. Geophysical Research Letters, 26, 1027\u20131030. https:\/\/doi.org\/10.1029\/1999GL900161","DOI":"10.1029\/1999GL900161"},{"key":"641423","unstructured":"Cardoso, A., Machado, P., & Duarte, J. (2023). Streaming Kolmogorov\u2013Smirnov: An approximate algorithm for distribution testing in real time. Journal of Computational Science, 68, 102016. https:\/\/doi.org\/10.1016\/j.jocs.2023.102016"},{"key":"641424","doi-asserted-by":"crossref","unstructured":"Charlton, P. H., van Velzen, J., & Clifton, D. A. (2025). Determinants of photoplethysmography signal quality at the wrist. PLOS Digital Health, 4(1). https:\/\/doi.org\/10.1371\/journal.pdig.0000585","DOI":"10.1371\/journal.pdig.0000585"},{"key":"641425","unstructured":"Corder, G. W., & Dale, I. F. (2023). Nonparametric statistics: A step-by-step approach (2nd ed.). Wiley. https:\/\/www.wiley.com\/en-us\/Nonparametric+Statistics%3A+A+Step-by-Step+Approach%2C+2nd+Edition-p-9781118840313"},{"key":"641426","doi-asserted-by":"crossref","unstructured":"Debnath, S., & Kim, D. (2025). A comprehensive review of heart rate measurement using remote photoplethysmography and deep learning. Biomedical Engineering Online, 24(1), 145. https:\/\/doi.org\/10.1186\/s12938-025-01405-5","DOI":"10.1186\/s12938-025-01405-5"},{"key":"641427","doi-asserted-by":"crossref","unstructured":"Elgendi, M. (2012). On the analysis of fingertip photoplethysmogram signals. Current Cardiology Reviews, 8(3), 14\u201325. https:\/\/www.eurekaselect.com\/article\/43575","DOI":"10.2174\/157340312801215782"},{"key":"641428","doi-asserted-by":"crossref","unstructured":"Elgendi, M., Fletcher, R., Howard, N., & Lovell, N. H. (2024). Recommendations for evaluating photoplethysmography-based algorithm performance. npj Digital Medicine, 7(1), 120. https:\/\/doi.org\/10.1038\/s43856-024-00555-2","DOI":"10.1038\/s43856-024-00555-2"},{"key":"641429","doi-asserted-by":"crossref","unstructured":"Gershunov, A., Schneider, N., & Barnett, T. (2001). Low-frequency modulation of the ENSO\u2013Indian monsoon rainfall relationship: Signal or noise? Journal of Climate, 14, 2486\u20132492. https:\/\/doi.org\/10.1175\/1520-0442(2001)014<2486:LFMOTE>2.0.CO;2","DOI":"10.1175\/1520-0442(2001)014<2486:LFMOTE>2.0.CO;2"},{"key":"641430","doi-asserted-by":"crossref","unstructured":"Ghaderi, E., & Bahreyni, B. (2021). Synchronous demodulation for low-noise measurements. IEEE Instrumentation & Measurement Magazine, 24(2), 72\u201378. https:\/\/doi.org\/10.1109\/MIM.2021.9400956","DOI":"10.1109\/MIM.2021.9400956"},{"key":"641431","doi-asserted-by":"crossref","unstructured":"Grillenzoni, C. (2019). Statistical change detection in biomedical signal processing. Array, 2, 100009. https:\/\/doi.org\/10.1016\/j.array.2019.100009","DOI":"10.1016\/j.array.2019.100009"},{"key":"641432","doi-asserted-by":"crossref","unstructured":"Hertzman, A. B. (1938). The blood supply of various skin areas as estimated by the photoelectric plethysmograph. American Journal of Physiology \u2013 Legacy Content, 124(2), 328\u2013340. https:\/\/doi.org\/10.1152\/ajplegacy.1938.124.2.328","DOI":"10.1152\/ajplegacy.1938.124.2.328"},{"key":"641433","doi-asserted-by":"crossref","unstructured":"JeyaJothi, R., Kumar, S., & Maheshwari, M. (2022). Computational models for obstructive sleep apnea detection using physiological signals. In Advances in Computational Intelligence and Machine Learning Applications (pp. 189\u2013206). Springer. https:\/\/doi.org\/10.1007\/978-981-16-8343-2_9","DOI":"10.1155\/2022\/7242667"},{"key":"641434","unstructured":"Kolmogorov, A. N. (1933). Sulla determinazione empirica di una legge di distribuzione. Giornale dell\u2019Istituto Italiano degli Attuari, 4, 83\u201391."},{"key":"641435","doi-asserted-by":"crossref","unstructured":"Kyriacou, P. A., & Chatterjee, S. (2022). The origin of photoplethysmography. In J. Allen & P. Kyriacou (Eds.), Photoplethysmography (pp. 17\u201343). Academic Press. https:\/\/doi.org\/10.1016\/B978-0-12-823374-0.00004-9","DOI":"10.1016\/B978-0-12-823374-0.00004-9"},{"key":"641436","doi-asserted-by":"crossref","unstructured":"Lanzante, J. R. (2021). Evaluating the Kolmogorov\u2013Smirnov two-sample test for climatological applications. International Journal of Climatology, 41(3), 1909\u20131924. https:\/\/doi.org\/10.1002\/joc.6903","DOI":"10.1002\/joc.7196"},{"key":"641437","doi-asserted-by":"crossref","unstructured":"Luiz, A. J. B., & Lima, M. A. de. (2021). Application of the Kolmogorov\u2013Smirnov test to compare greenhouse gas emissions over time. Brazilian Journal of Biometrics, 39(1), 60\u201370. https:\/\/doi.org\/10.28951\/rbb.v39i1.498","DOI":"10.28951\/rbb.v39i1.498"},{"key":"641438","doi-asserted-by":"crossref","unstructured":"Massey, F. J. (1951). The Kolmogorov\u2013Smirnov test for goodness of fit. Journal of the American Statistical Association, 46(253), 68\u201378. https:\/\/doi.org\/10.1080\/01621459.1951.10500769","DOI":"10.1080\/01621459.1951.10500769"},{"key":"641439","doi-asserted-by":"crossref","unstructured":"Moccia, B., Mineo, C., Ridolfi, E., Russo, F., & Napolitano, F. (2021). Probability distributions of daily rainfall extremes in Lazio and Sicily, Italy, and design rainfall inferences. Journal of Hydrology: Regional Studies, 33, 100771. https:\/\/doi.org\/10.1016\/j.ejrh.2020.100771","DOI":"10.1016\/j.ejrh.2020.100771"},{"key":"641440","unstructured":"Montgomery, D. C., & Runger, G. C. (2018). Applied statistics and probability for engineers (7th ed.). Wiley."},{"key":"641441","doi-asserted-by":"crossref","unstructured":"Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010). Non-contact, automated cardiac pulse measurements using video imaging and blind source separation. Optics Express, 18(10), 10762\u201310774. https:\/\/doi.org\/10.1364\/OE.18.010762","DOI":"10.1364\/OE.18.010762"},{"key":"641442","doi-asserted-by":"crossref","unstructured":"Pstras, L., Sliwinski, P., & Gielerak, G. (2025). Facial video photoplethysmography for measuring average and quasi-instantaneous heart rate. Frontiers in Physiology, 16, 1638809. https:\/\/doi.org\/10.3389\/fphys.2025.1638809","DOI":"10.3389\/fphys.2025.1638809"},{"key":"641443","doi-asserted-by":"crossref","unstructured":"Ramos-Frutos, J., Cruz-Salgado, J., Ramos-Soto, O., Miguel-Andr\u00e9s, I., P\u00e9rez-Ch\u00e1vez, R., Oliva, D., Casas-Ordaz, \u00c1., \u00c7elik, E., & Nadimi-Shahraki, M. H. (2025). Improving the response surface methodology optimization with metaheuristics: A practical approach. Expert Systems with Applications, 129195. https:\/\/doi.org\/10.1016\/j.eswa.2025.129195","DOI":"10.1016\/j.eswa.2025.129195"},{"key":"641444","doi-asserted-by":"crossref","unstructured":"Servin, M., Malacara, D., & Rodr\u00edguez-Vera, R. (1994). Phase-locked-loop interferometry applied to aspheric testing with a computer-stored compensator. Applied Optics, 33(13), 2589\u20132595. https:\/\/doi.org\/10.1364\/AO.33.002589","DOI":"10.1364\/AO.33.002589"},{"key":"641445","doi-asserted-by":"crossref","unstructured":"Smirnov, N. V. (1948). Table for estimating the goodness of fit of empirical distributions. The Annals of Mathematical Statistics, 19(2), 279\u2013281. https:\/\/doi.org\/10.1214\/aoms\/1177730256","DOI":"10.1214\/aoms\/1177730256"},{"key":"641446","unstructured":"Stearns, S. D., & Hush, D. R. (2011). Digital signal processing with examples in MATLAB (2nd ed.). CRC Press."},{"key":"641447","doi-asserted-by":"crossref","unstructured":"Steinskog, D. J., Tj\u00f8stheim, D., & Kvamst\u00f8, N. G. (2007). A cautionary note on the use of the Kolmogorov\u2013Smirnov test for normality. Monthly Weather Review, 135(3), 1151\u20131157. https:\/\/doi.org\/10.1175\/MWR3319.1","DOI":"10.1175\/MWR3326.1"},{"key":"641448","doi-asserted-by":"crossref","unstructured":"Stephens, M. A. (1970). Use of the Kolmogorov\u2013Smirnov, Cram\u00e9r\u2013von Mises and related statistics without extensive tables. Journal of the Royal Statistical Society: Series B (Methodological), 32(1), 115\u2013122. https:\/\/doi.org\/10.1111\/j.2517-6161.1970.tb00821.x","DOI":"10.1111\/j.2517-6161.1970.tb00821.x"},{"key":"641449","doi-asserted-by":"crossref","unstructured":"Stephenson, D. B., Hannachi, A., & O\u2019Neill, A. (2004). On the existence of multiple climate regimes. Quarterly Journal of the Royal Meteorological Society, 130, 583\u2013605. https:\/\/doi.org\/10.1256\/qj.02.146","DOI":"10.1256\/qj.02.146"},{"key":"641450","doi-asserted-by":"crossref","unstructured":"Strasser, T., Kapsner, L. A., & Keller, T. (2025). Insight on forehead photoplethysmography sensors: Wearables, advances and challenges. Nature Biomedical Engineering, 9(2), 243\u2013257. https:\/\/doi.org\/10.1038\/s41390-025-04376-4","DOI":"10.1038\/s41390-025-04376-4"},{"key":"641451","doi-asserted-by":"crossref","unstructured":"Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014). Wearable photoplethysmographic sensors\u2014Past and present. Electronics, 3(2), 282\u2013302. https:\/\/doi.org\/10.3390\/electronics3020282","DOI":"10.3390\/electronics3020282"},{"key":"641452","doi-asserted-by":"crossref","unstructured":"Vl\u010dek, O., & Huth, R. (2009). Is daily precipitation gamma-distributed? Testing using the two-sample Kolmogorov\u2013Smirnov test. Agricultural and Forest Meteorology, 149(2), 405\u2013412. https:\/\/doi.org\/10.1016\/j.agrformet.2008.09.010","DOI":"10.1016\/j.agrformet.2008.09.010"},{"key":"641453","doi-asserted-by":"crossref","unstructured":"van Vliet, L., Meeus, M., & Wuyts, F. L. (2025). Assessment of photoplethysmography-based blood pressure monitoring device over 28 days. European Heart Journal \u2013 Digital Health, 6(4), 763\u2013772. https:\/\/doi.org\/10.1093\/ehjdh\/ztad115","DOI":"10.1093\/ehjdh\/ztaf027"},{"key":"641454","doi-asserted-by":"crossref","unstructured":"Weiss, N. A. (1986). Modified Kolmogorov\u2013Smirnov tests for correlated data. IEEE Transactions on Biomedical Engineering, 33(12), 1130\u20131134. https:\/\/doi.org\/10.1109\/TBME.1986.325697","DOI":"10.1109\/TBME.1986.325688"},{"key":"641455","doi-asserted-by":"crossref","unstructured":"Zeimbekakis, A., Langren\u00e9, N., & Ferrari, D. (2024). When the Kolmogorov\u2013Smirnov one-sample test is misused: A cautionary review. The American Statistician, 78(1), 34\u201344. https:\/\/doi.org\/10.1080\/00031305.2023.2211427","DOI":"10.1080\/00031305.2024.2356095"}],"container-title":["Journal of Applied Research in Technology &amp; Engineering"],"original-title":[],"link":[{"URL":"https:\/\/polipapers.upv.es\/index.php\/JARTE\/article\/download\/24883\/18067","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/polipapers.upv.es\/index.php\/JARTE\/article\/download\/24883\/18067","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,30]],"date-time":"2026-01-30T11:47:52Z","timestamp":1769773672000},"score":1,"resource":{"primary":{"URL":"https:\/\/polipapers.upv.es\/index.php\/JARTE\/article\/view\/24883"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,27]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,10,15]]}},"URL":"https:\/\/doi.org\/10.4995\/jarte.2026.24883","relation":{},"ISSN":["2695-8821"],"issn-type":[{"value":"2695-8821","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,27]]}}}