{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,26]],"date-time":"2026-03-26T00:13:08Z","timestamp":1774483988872,"version":"3.50.1"},"reference-count":13,"publisher":"Jaypee Brothers Medical Publishing","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,3,20]]},"DOI":"10.5005\/jp-journals-10080-1629","type":"journal-article","created":{"date-parts":[[2025,3,21]],"date-time":"2025-03-21T12:29:20Z","timestamp":1742560160000},"page":"171-176","source":"Crossref","is-referenced-by-count":1,"title":["Extraction of a Broken PRECICE Bone Transport System: A Case Report and Technique for Residual Limb Salvage"],"prefix":"10.5005","volume":"19","author":[{"given":"Mitchell","family":"Bernstein","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jack","family":"Legler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Martel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pascal","family":"Mailhot","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2914","published-online":{"date-parts":[[2025,3,20]]},"reference":[{"key":"ref=1","doi-asserted-by":"crossref","unstructured":"1. Quinnan SM. Segmental bone loss reconstruction using ring fixation. J Orthop Trauma 2017;31(Suppl 5):S42\u2212S46. DOI: 10.1097\/BOT.0000000000000985.","DOI":"10.1097\/BOT.0000000000000985"},{"key":"ref=2","doi-asserted-by":"crossref","unstructured":"2. Kocaoglu M, Eralp L, Rashid HU, et al. Reconstruction of segmental bone defects due to chronic osteomyelitis with use of an external fixator and an intramedullary nail. J Bone Joint Surg Am 2006;88(10):2137\u22122145. DOI: 10.2106\/JBJS.E.01152.","DOI":"10.2106\/00004623-200610000-00004"},{"key":"ref=3","doi-asserted-by":"crossref","unstructured":"3. Landge V, Shabtai L, Gesheff M, et al. Patient satisfaction after limb lengthening with internal and external devices. J Surg Orthop Adv 2015;24(3):174\u2212179. PMID: 26688988.","DOI":"10.3113\/JSOA.2015.0174"},{"key":"ref=4","doi-asserted-by":"crossref","unstructured":"4. Frost MW, Rahbek O, Traerup J, et al. Systematic review of complications with externally controlled motorized intramedullary bone lengthening nails (FITBONE and PRECICE) in 983 segments. Acta Orthop 2021;92(1):120\u2212127. DOI: 10.1080\/17453674.2020.1835321.","DOI":"10.1080\/17453674.2020.1835321"},{"key":"ref=5","doi-asserted-by":"crossref","unstructured":"5. Tiefenbock TM, Wozasek GE. Unusual complication with an intramedullary lengthening device 15 months after implantation. Injury 2015;46(10):2069\u22122072. DOI: 10.1016\/j.injury.2015.07.033.","DOI":"10.1016\/j.injury.2015.07.033"},{"key":"ref=6","doi-asserted-by":"crossref","unstructured":"6. Giannoudis PV, Matthews SJ, Smith RM. Removal of the retained fragment of broken solid nails by the intra-medullary route. Injury 2001;32(5):407\u2212410. DOI: 10.1016\/s0020-1383(00)00236-9.","DOI":"10.1016\/S0020-1383(00)00236-9"},{"key":"ref=7","doi-asserted-by":"crossref","unstructured":"7. Lee DH, Kim S, Lee JW, et al. A comparison of the device-related complications of intramedullary lengthening nails using a new classification system. Biomed Res Int 2017;2017:8032510. DOI: 10.1155\/2017\/8032510.","DOI":"10.1155\/2017\/8032510"},{"key":"ref=8","doi-asserted-by":"crossref","unstructured":"8. Hlukha LP, Alrabai HM, Sax OC, et al. Mechanical failures in magnetic intramedullary lengthening nails. J Bone Joint Surg Am 2023;105(2):113\u2212127. DOI: 10.2106\/JBJS.22.00283.","DOI":"10.2106\/JBJS.22.00283"},{"key":"ref=9","doi-asserted-by":"crossref","unstructured":"9. Lovell J, Krishna D, Gehr E. Stuffing the nail: A simple technique for the extraction of a broken femoral nail. Trauma Case Rep 2017;9:38\u221241. DOI: 10.1016\/j.tcr.2017.05.011.","DOI":"10.1016\/j.tcr.2017.05.011"},{"key":"ref=10","doi-asserted-by":"crossref","unstructured":"10. Zhao C, Slater GJR. A technique for extraction of the distal segment of a broken femoral nail using a flexible reamer. Injury 2017;48(8):1858\u22121860. DOI: 10.1016\/j.injury.2017.06.010.","DOI":"10.1016\/j.injury.2017.06.010"},{"key":"ref=11","doi-asserted-by":"crossref","unstructured":"11. Krettek C, Mommsen P. [Implant removal after intramedullary osteosyntheses. Literature review, technical details, and tips and tricks]. Unfallchirurg 2012;115(4):299\u2212314. DOI: 10.1007\/s00113-012-2158-3.","DOI":"10.1007\/s00113-012-2158-3"},{"key":"ref=12","doi-asserted-by":"crossref","unstructured":"12. Hidden KA, Dahl MT, Ly TV. Management of a broken PRECICE femoral nail at an ununited distraction osteogenesis site: A case report. JBJS Case Connect 2020;10(1):e0267. DOI: 10.2106\/JBJS.CC.19.00267.","DOI":"10.2106\/JBJS.CC.19.00267"},{"key":"ref=13","doi-asserted-by":"crossref","unstructured":"13. Johnson MA, Karkenny AJ, Arkader A, et al. Dissociation of a femoral intramedullary magnetic lengthening nail during routine hardware removal: A case report. JBJS Case Connect 2021;11(1):1\u22125. DOI: 10.2106\/JBJS.CC.20.00950.","DOI":"10.2106\/JBJS.CC.20.00950"}],"container-title":["Strategies in Trauma and Limb Reconstruction"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.stlrjournal.com\/doi\/pdf\/10.5005\/jp-journals-10080-1629","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,4,3]],"date-time":"2025-04-03T06:51:01Z","timestamp":1743663061000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.stlrjournal.com\/doi\/10.5005\/jp-journals-10080-1629"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,20]]},"references-count":13,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2024]]}},"alternative-id":["10.5005\/jp-journals-10080-1629"],"URL":"https:\/\/doi.org\/10.5005\/jp-journals-10080-1629","relation":{},"ISSN":["1828-8936","1828-8928"],"issn-type":[{"value":"1828-8936","type":"print"},{"value":"1828-8928","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,20]]}}}