{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:41:51Z","timestamp":1762868511285,"version":"3.40.3"},"reference-count":24,"publisher":"Termedia Sp. z.o.o.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesiol Intensive Ther"],"abstract":"<jats:p>Hemodynamic optimization is vital in high risk surgical patients or in high risk surgical procedures. The main objective of hemodynamic management is to maintain tissue perfusion and preserve aerobic metabolism through a\u00a0cardiac output coupled with the metabolic demand. The technologies used for cardiac output monitoring use special techniques (e.g. lithium dilution or transpulmonary thermodilution) or implementation of dedicated devices with considerable rates of potential complications (pulmonary artery catheter). Thus, we propose a\u00a0novel method to estimate cardiac output through the analysis of arteriovenous blood gases which could be an alternative to more expensive methods (minimally invasive devices, pulmonary artery catheter). A\u00a0review of several formulas described in the literature to compute the variables needed to calculate cardiac output with the Fick principle was carried out. These formulas estimate the oxygen consumption using the O2 sensor integrated in the anesthesia workstation. &lt;br \/&gt;\nThe other variables in the Fick equation are derived from the arterial and venous blood gas analysis and parameters obtained from mechanical ventilators. By integrating the data gathered from the publications found, the authors created a\u00a0comprehensive formula for calculation of cardiac output and the cardiac index using the parameters obtained from blood gas analysis. The presented method provides a\u00a0more accessible and affordable way to monitor cardiac output in surgical high-risk patients in an environment with limited resources.<\/jats:p>","DOI":"10.5114\/ait.2021.105730","type":"journal-article","created":{"date-parts":[[2021,5,18]],"date-time":"2021-05-18T06:58:35Z","timestamp":1621321115000},"page":"179-183","source":"Crossref","is-referenced-by-count":3,"title":["Cardiac output estimation based on arterial and venous blood gas analysis: proposal of a\u00a0monitoring method"],"prefix":"10.5114","volume":"53","author":[{"given":"David","family":"Santiago Giraldo Guti\u00e9rrez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juan","family":"Jos\u00e9 Vel\u00e1squez Guti\u00e9rrez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joaqu\u00edn","family":"Octavio Ruiz-Villa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"3061","published-online":{"date-parts":[[2021,5,13]]},"reference":[{"key":"ref-1379494","doi-asserted-by":"publisher","DOI":"10.4103\/aca.ACA_41_18"},{"key":"ref-1379495","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-012-9389-2"},{"key":"ref-1379496","doi-asserted-by":"publisher","DOI":"10.1053\/j.jvca.2017.09.006"},{"key":"ref-1379497","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aer030"},{"key":"ref-1379498","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0200740"},{"key":"ref-1379499","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aet025"},{"key":"ref-1379500","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-012-2617-x"},{"key":"ref-1379501","doi-asserted-by":"publisher","DOI":"10.4065\/mcp.2009.0336"},{"key":"ref-1379502","doi-asserted-by":"publisher","DOI":"10.1097\/MCC.0000000000000198"},{"key":"ref-1379503","doi-asserted-by":"publisher","DOI":"10.1016\/j.jclinane.2011.09.008"},{"key":"ref-1379504","doi-asserted-by":"publisher","DOI":"10.1097\/ALN.0b013e3181ee3130"},{"key":"ref-1379505","doi-asserted-by":"publisher","DOI":"10.1007\/s00246-019-02238-5"},{"key":"ref-1379506","volume-title":"Bogot\u00e1","author":"Pinsky M","year":"2012","unstructured":"Pinsky M, Brochard L, Mancebo J, Hedenstierna G. Fisiolog\u00eda aplicada en medicina de cuidado intensivo. 2nd ed. Editorial D (ed.). Bogot\u00e1; 2012."},{"key":"ref-1379507","doi-asserted-by":"publisher","DOI":"10.1186\/s13054-014-0579-9"},{"key":"ref-1379508","first-page":"165","article-title":"Saturaci\u00f3n venosa central. Conceptos actuales","volume":"30","author":"Carrillo-Esper R","year":"2007","unstructured":"Carrillo-Esper R, N\u00fa\u0144ez-Bacarreza JJ, Carrillo-C\u00f3rdova JR. Saturaci\u00f3n venosa central. Conceptos actuales. Rev Mex Anestesiol 2007; 30: 165-171.","journal-title":"Rev Mex Anestesiol"},{"key":"ref-1379509","doi-asserted-by":"publisher","DOI":"10.1016\/j.bpa.2014.09.006"},{"key":"ref-1379510","doi-asserted-by":"publisher","DOI":"10.1016\/j.bpa.2013.06.001"},{"key":"ref-1379511","doi-asserted-by":"publisher","DOI":"10.1007\/s00134-004-2337-y"},{"key":"ref-1379512","doi-asserted-by":"publisher","DOI":"10.1097\/PCC.0b013e318193699d"},{"key":"ref-1379513","doi-asserted-by":"publisher","DOI":"10.1007\/s10877-010-9222-8"},{"key":"ref-1379514","doi-asserted-by":"publisher","DOI":"10.1111\/anae.13899"},{"key":"ref-1379515","first-page":"67","article-title":"C\u00e1lculo de los contenidos arterial y venoso de ox\u00edgeno, de la diferencia arteriovenosa de ox\u00edgeno, tasa de extracci\u00f3n tisular de ox\u00edgeno y shunt intrapulmonar con unas nuevas f\u00f3rmulas, basadas en la saturaci\u00f3n de ox\u00edgeno","volume":"48","author":"G\u00f3mez Duque A","year":"2000","unstructured":"G\u00f3mez Duque A, Fern\u00e1ndez G, Augusto Guti\u00e9rrez \u00c1, et al. C\u00e1lculo de los contenidos arterial y venoso de ox\u00edgeno, de la diferencia arteriovenosa de ox\u00edgeno, tasa de extracci\u00f3n tisular de ox\u00edgeno y shunt intrapulmonar con unas nuevas f\u00f3rmulas, basadas en la saturaci\u00f3n de ox\u00edgeno. Rev la Fac Med 2000; 48: 67-76.","journal-title":"Rev la Fac Med"},{"key":"ref-1379516","doi-asserted-by":"publisher","DOI":"10.1111\/anae.14047"},{"key":"ref-1379517","doi-asserted-by":"publisher","DOI":"10.4187\/respcare.02116"}],"container-title":["Anaesthesiology Intensive Therapy"],"original-title":[],"link":[{"URL":"https:\/\/www.ait-journal.com\/pdf-127673-121878","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ait-journal.com\/pdf-127673-121878","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T10:57:03Z","timestamp":1743073023000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ait-journal.com\/Cardiac-output-estimation-based-on-arterial-and-venous-blood-gas-analysis-proposal,127673,0,2.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,13]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021]]}},"alternative-id":["127673"],"URL":"https:\/\/doi.org\/10.5114\/ait.2021.105730","relation":{},"ISSN":["1642-5758","1731-2531"],"issn-type":[{"type":"print","value":"1642-5758"},{"type":"electronic","value":"1731-2531"}],"subject":[],"published":{"date-parts":[[2021,5,13]]}}}