{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T20:00:58Z","timestamp":1790884858242,"version":"4.1.0"},"reference-count":58,"publisher":"Termedia Sp. z.o.o.","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Anaesthesiol Intensive Ther"],"abstract":"<jats:sec><jats:title>Introduction<\/jats:title><jats:p>The Air-Q Self Pressurized Airway Device with Blocker (SP Blocker) was compared to the Proseal Laryngeal Mask Airway (PLMA) during positive pressure ventilation regarding the primary outcome (oropharyngeal leak pressure [OLP]), secondary outcomes (peak inspiratory pressure [PIP], inspired tidal volume [ITV], expired tidal volume [ETV], leak volume [LV] and leak fraction [LF]), insertion time, ventilation score, fiber-optic glottis view score, and postoperative laryngopharyngeal parameters (LPM).<\/jats:p><\/jats:sec><jats:sec><jats:title>Material and methods<\/jats:title><jats:p>Adult healthy female patients scheduled for elective gynecological laparotomies under general anesthesia using controlled mechanical ventilation were recruited to a prospective randomized comparative clinical trial. Exclusion criteria were body mass index (BMI) \u2265 35 kg m&lt;sup&gt;\u20132&lt;\/sup&gt;, El-Ganzouri score \u2265 5, upper airway problems, hiatus hernia or pregnancy. Patients were classified into an SP Blocker group (&lt;i&gt;n&lt;\/i&gt; = 75) and a PLMA group (&lt;i&gt;n&lt;\/i&gt; = 75). Primary and secondary outcomes were assessed initially and at fixed time points after successful insertion of devices.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Initially after successful device insertion: the SP Blocker group showed statistically significant higher mean OLP (cmH&lt;sub&gt;2&lt;\/sub&gt;O) (29.46 \u00b1 2.11 vs. 28.06 \u00b1 1.83 respectively; 95% CI: \u20132.037 to \u20130.76, &lt;i&gt;P&lt;\/i&gt; &lt; 0.0001), lower mean PIP (cmH&lt;sub&gt;2&lt;\/sub&gt;O) (15.49 \u00b1 0.61 vs. 17.78 \u00b1 1.04 respectively; 95% CI: 2.02 to 2.56, &lt;i&gt;P&lt;\/i&gt; &lt; 0.0001), higher mean ITV (mL) (411 \u00b1 30 vs. 403 \u00b1 15 respectively; 95% CI: \u201315.65 to \u20130.347, &lt;i&gt;P&lt;\/i&gt; = 0.041), higher mean ETV (mL) (389 \u00b1 12 vs. 354 \u00b1 11 respectively; 95% CI: \u201338.72 to \u201331.29, &lt;i&gt;P&lt;\/i&gt; &lt; 0.0001), lower mean LV (mL) (22 \u00b1 18 vs. 49 \u00b1 10 respectively; 95% CI: 22.3 to 31.7, &lt;i&gt;P&lt;\/i&gt; &lt; 0.0001) and lower mean LF (%) (5 \u00b1 2.04 vs. 12 \u00b1 6.8 respectively; 95% CI: 5.38 to 8.62, &lt;i&gt;P&lt;\/i&gt; &lt; 0.0001) than the PLMA group. Mean insertion time (seconds) was shorter in the SP Blocker group than the PLMA group (16.39 \u00b1 2.81 vs. 18.63 \u00b1 3.44 respectively; 95% CI: 1.23 to 3.25, &lt;i&gt;P&lt;\/i&gt; &lt; 0.0001). The SP Blocker group offered a better fiber-optic glottis view score than the PLMA group without differences concerning ventilation score and LPM.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>SP Blocker provided as safe anesthesia during controlled mechanical ventilation as PLMA.<\/jats:p><\/jats:sec>","DOI":"10.5114\/ait.2024.141203","type":"journal-article","created":{"date-parts":[[2024,8,2]],"date-time":"2024-08-02T08:24:07Z","timestamp":1722587047000},"page":"108-120","source":"Crossref","is-referenced-by-count":2,"title":["Comparison between Air-Q Self Pressurized Airway Device with Blocker and Proseal Laryngeal Mask Airway in anesthetized paralyzed adult female patients undergoing elective gynecological operations"],"prefix":"10.5114","volume":"56","author":[{"given":"Maha Mohammed","family":"Ismail Youssef","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Naser Mohammed","family":"Dobal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yahya Mohamed","family":"Hammad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nesrine Abdel Rahman","family":"El-Refai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reham Ali Abdelhaleem","family":"Abdelrahman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3061","published-online":{"date-parts":[[2024,7,23]]},"reference":[{"key":"ref-1373405","doi-asserted-by":"publisher","DOI":"10.1093\/bjaceaccp\/mkq058"},{"key":"ref-1373406","doi-asserted-by":"publisher","DOI":"10.14712\/23362936.2014.40"},{"key":"ref-1373407","doi-asserted-by":"publisher","DOI":"10.4172\/2155-6148.1000647"},{"key":"ref-1373408","year":"2001","unstructured":"LMA-Proseal Instructions Manual. San Diego: LMA North America; 2001."},{"key":"ref-1373409","doi-asserted-by":"publisher","DOI":"10.4103\/joacp.joacp_248_22"},{"key":"ref-1373410","doi-asserted-by":"publisher","DOI":"10.1097\/EJA.0b013e32834698f4"},{"key":"ref-1373411","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/82.2.286"},{"key":"ref-1373412","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aew448"},{"key":"ref-1373413","doi-asserted-by":"publisher","DOI":"10.1093\/bja\/aep056"},{"key":"ref-1373414","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2012.07140.x"},{"key":"ref-1373415","doi-asserted-by":"publisher","DOI":"10.1097\/EJA.0b013e32835aba6a"},{"key":"ref-1373416","doi-asserted-by":"publisher","DOI":"10.4103\/0970-9185.105798"},{"key":"ref-1373417","doi-asserted-by":"publisher","DOI":"10.1055\/s-2000-8164"},{"key":"ref-1373418","first-page":"457","article-title":"A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position","volume":"76","author":"Brimacombe J","year":"1993","unstructured":"Brimacombe J, Berry A. A proposed fiber-optic scoring system to standardize the assessment of laryngeal mask airway position. Anesth Analg 1993; 76: 457.","journal-title":"Anesth Analg"},{"key":"ref-1373419","doi-asserted-by":"publisher","DOI":"10.1097\/00000542-200209002-01321"},{"key":"ref-1373420","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/705869"},{"key":"ref-1373421","doi-asserted-by":"publisher","DOI":"10.4103\/joacp.JOACP_24_17"},{"key":"ref-1373422","doi-asserted-by":"publisher","DOI":"10.18535\/jmscr\/v5i2.96"},{"key":"ref-1373423","doi-asserted-by":"crossref","first-page":"15","DOI":"10.4103\/TheIAForum.TheIAForum_1_18","article-title":"A comparison of metal introducer and bougie-guided techniques of insertion PLMA\u2122 with respect to cuff position and air leak","volume":"19","author":"Sharma D","year":"2018","unstructured":"Sharma D, Ahmed B, Tiwary V, K Malhotra MM, Agarwal D, Kaur S. A comparison of metal introducer and bougie-guided techniques of insertion PLMA\u2122 with respect to cuff position and air leak. Indian Anaesth Forum 2018; 19: 15-21. http:\/\/www.theiaforum.org\/text.asp?2018\/19\/1\/15\/232915.","journal-title":"Indian Anaesth Forum"},{"key":"ref-1373424","doi-asserted-by":"publisher","DOI":"10.1097\/00000539-200205000-00080"},{"key":"ref-1373425","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2010.06534.x"},{"key":"ref-1373426","doi-asserted-by":"publisher","DOI":"10.4097\/kjae.2012.63.6.510"},{"key":"ref-1373427","article-title":"London, UK","author":"Altman DG","year":"1991","unstructured":"Altman DG. Practical Statistics for Medical Research. London, UK; Chapman & Hall; 1991."},{"key":"ref-1373428","volume-title":"Statistics in Practice","author":"Altman DG","year":"1982","unstructured":"Altman DG. How large a sample? In: Gore SM, Altman DG (eds.). Statistics in Practice. London, UK: British Medical Association; 1982."},{"key":"ref-1373429","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-017-0936-7"},{"key":"ref-1373430","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2011.06863.x"},{"key":"ref-1373431","unstructured":"http:\/\/www.mercurymed.com."},{"key":"ref-1373432","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X1003800217"},{"key":"ref-1373433","doi-asserted-by":"publisher","DOI":"10.1155\/2016\/6406391"},{"key":"ref-1373434","doi-asserted-by":"publisher","DOI":"10.4103\/0970-9185.142904"},{"key":"ref-1373435","doi-asserted-by":"publisher","DOI":"10.1016\/j.egja.2014.01.009"},{"key":"ref-1373436","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2044.2012.07199.x"},{"key":"ref-1373437","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000014746"},{"key":"ref-1373438","doi-asserted-by":"publisher","DOI":"10.24966\/ACC-8879\/100047"},{"key":"ref-1373439","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X0703500106"},{"key":"ref-1373440","doi-asserted-by":"publisher","DOI":"10.1007\/BF03016565"},{"key":"ref-1373441","doi-asserted-by":"publisher","DOI":"10.1177\/0300060515607386"},{"key":"ref-1373442","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-018-1082-6"},{"key":"ref-1373443","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2011.03576.x"},{"key":"ref-1373444","doi-asserted-by":"publisher","DOI":"10.4103\/joacp.JOACP_397_17"},{"key":"ref-1373445","doi-asserted-by":"publisher","DOI":"10.4103\/asja.asja_111_16"},{"key":"ref-1373446","doi-asserted-by":"publisher","DOI":"10.18231\/j.ijca.2019.067"},{"key":"ref-1373447","doi-asserted-by":"publisher","DOI":"10.1213\/ane.0b013e318192376f"},{"key":"ref-1373448","doi-asserted-by":"publisher","DOI":"10.4103\/0259-1162.200238"},{"key":"ref-1373449","doi-asserted-by":"publisher","DOI":"10.1155\/2015\/201898"},{"key":"ref-1373450","doi-asserted-by":"publisher","DOI":"10.1213\/ANE.0b013e31823b6784"},{"key":"ref-1373451","doi-asserted-by":"publisher","DOI":"10.5152\/TJAR.2017.67764"},{"key":"ref-1373452","doi-asserted-by":"publisher","DOI":"10.1111\/j.1460-9592.2011.03703.x"},{"key":"ref-1373453","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X-1204000614"},{"key":"ref-1373454","doi-asserted-by":"publisher","DOI":"10.1111\/pan.12609"},{"key":"ref-1373455","first-page":"1125","article-title":"Air-Q\u00ae intubating laryngeal airway as a conduit for tracheal intubation in a patient with Apert syndrome: a case report (Japanese)","volume":"63","author":"Nishimoto K","year":"2014","unstructured":"Nishimoto K, Kariya N, Iwasaki Y, Shii H, Sugi T, Tatara T, et al. Air-Q\u00ae intubating laryngeal airway as a conduit for tracheal intubation in a patient with Apert syndrome: a case report (Japanese). Masui 2014; 63: 1125-1127 [Article in Japanese].","journal-title":"Masui"},{"key":"ref-1373456","doi-asserted-by":"publisher","DOI":"10.1097\/EJA.0000000000000019"},{"key":"ref-1373457","doi-asserted-by":"publisher","DOI":"10.1111\/pan.12462"},{"key":"ref-1373458","doi-asserted-by":"publisher","DOI":"10.4103\/1658-354X.140841"},{"key":"ref-1373459","doi-asserted-by":"publisher","DOI":"10.1111\/pan.12663"},{"key":"ref-1373460","doi-asserted-by":"publisher","DOI":"10.1111\/pan.12024"},{"key":"ref-1373461","doi-asserted-by":"publisher","DOI":"10.1007\/s12630-014-0304-9"},{"key":"ref-1373462","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000014746"}],"container-title":["Anaesthesiology Intensive Therapy"],"original-title":[],"link":[{"URL":"https:\/\/www.ait-journal.com\/pdf-177687-121666","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.ait-journal.com\/pdf-177687-121666","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,27]],"date-time":"2025-03-27T10:17:03Z","timestamp":1743070623000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ait-journal.com\/Comparison-between-Air-Q-Self-Pressurized-Airway-Device-with-Blocker-and-Proseal,177687,0,2.html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,23]]},"references-count":58,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024]]}},"alternative-id":["177687"],"URL":"https:\/\/doi.org\/10.5114\/ait.2024.141203","relation":{},"ISSN":["1642-5758","1731-2531"],"issn-type":[{"value":"1642-5758","type":"print"},{"value":"1731-2531","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,23]]}}}